Laserfiche WebLink
• <br /> • Intertek Testing Services NA Inc. <br /> Report No.3054850-003 Page 2 Issued:4/26/04 <br /> Garmat USA Inc. Revised:09/15/04 <br /> PRODUCT DESCRIPTION <br /> PRODUCTS COVERED: <br /> Products covered are direct fired heaters,model numbers—42010,42010X,42106,42106X,46008,46008X,48106,48106X <br /> PRODUCT DESCRIPTION <br /> The product covered by this report is a paint spray booth that has a ventilation system interlocked to the spray application equipment.The paint <br /> spray booth incorporates a natural gas or propane(LPG)Direct Gas Fired Heater that is an integral part of the paint spray booth cabin.The <br /> product is provided with a Listed Industrial Control Panel,and Listed Electric Lighting Fixtures for Use in Hazardous Locations.The paint <br /> spray booth is fully automated with Spray and Bake Cycles of operation.The paint spray booth is permanently connected to the electrical supply <br /> source.The heater pre-conditions the incoming air to a maximum 01 200°F.and is connected through permanently installed ducting.The <br /> exhaust ventilation is also connected through permanently installed ducting to a safe discharge location. <br /> • Fuels—Natural Gas,LP Gas(LP gas noted through"P"designation at the end of the model number) <br /> • Unit Configuration—Down Flow,Blow Through <br /> • Discharge Configuration—Horizontal <br /> • Clearances to Combustible Material—4"from top,sides and ends.(For service clearances,the distance of the door to 90 degrees is used.) <br /> • For installation on Non-Combustible Surfaces. <br /> MODEL SIMILARITY <br /> All models within the model line are manufactured using the same style cabinet in varying sizes.The burner in a 42000 model <br /> series may vary from to three feet of burner length.To verify the proper velocity over the burner use the following relationship: <br /> Burner shadow area=Length of burner x(See Table A for Burner Area's) <br /> Profile area(sq.in.)=[(CFM_profile velocity)+burner shadow area]x 144=Length of profile x width of profile. <br /> Velocity over the burner(ft/min)=Unit CFM divided by(profile area—burner shadow area) <br /> Firing Rate(btu/hr per linear foot of burner) <br /> Model Midco HMA-2 <br /> 42010 500,000 <br /> 42010X 500,000 <br /> 42106 500,000 <br /> 42106X 500,000 <br /> 46008 500,000 <br /> 46008X 500,000 <br /> 48106 500,000 <br /> 48106X 500,000 <br /> Table A <br /> Midco HMA-2 Area <br /> 12"Straight Back Inlet,H-1361 .65 Sq. Ft. <br />