3927 RUCKER AVE BASE FILE 2019-09-24
>
Address Records
>
RUCKER AVE
>
3927
>
BASE FILE
>
3927 RUCKER AVE BASE FILE 2019-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2019 10:41:11 AM
Creation date
9/24/2019 10:41:00 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EVOLUTION <br /> FIELD REVIEW REPORT 01 <br /> ARCHITECTURE <br /> Project : Gunderson Building Field Review Date: 07/19/18 <br /> Client: The Everett Clinic Report Date: 07/26/18 <br /> Report By: Ralph Allen <br /> Attendance: Craig Kuanoni,Evolution(EA);Ralph Allen,Evolution(EA);George Bruce, <br /> We met on site prior to the regular meeting to review the field conditions relating primarily to the WRB application with <br /> the existing windows remaining in place and other related field conditions as noted below: <br /> Field Notes#01 Comments: <br /> WRB application/ 10 year The 10-year warranty applies to those areas where the approved system is <br /> warranty applied. In the instance where the existing windows are left in place and <br /> WRB materials are not able to be applied,the warranty will exclude these <br /> elements as they may relate to any contribution to any future failure. The <br /> likelihood of failure at the existing window rough opening is minimal in <br /> these circumstances where the vast majority of the windows are well <br /> recessed into the interior wall. <br /> Return wall condition at recessed We agreed to reduce the insulation thickness at the return wall to 1"or as <br /> windows and Prosoco application required to allow for a face out 1/4"sealant joint at the jamb conditions. <br /> at jamb returns This may apply to the head return condition depending on individual <br /> dimensional circumstances. <br /> The framing at these conditions should also be coated with Prosoco liquid <br /> flashing to supplement the termination at these locations. <br /> Sloped Sill No rigid insulation is required at the sloped sill,allowing the specified <br /> metal cladding to fit existing conditions—A field mock up will be <br /> implemented prior to installation. <br /> Wall insulation There are areas of the existing wall where there is either no insulation or <br /> the original installation has fell of into the interstitial cavity leaving areas <br /> of the existing wall uninsulated. Contractor shall install new batt <br /> insulation matching the existing materials in all areas where it is missing <br /> and re-attach existing materials with an industry acceptable method. <br /> Contractor has brought in a specialist sub to implement this segment of the <br /> work. <br /> Conditions at MRI coolant line We agreed that the existing vertical supports would remain at their current <br /> cover datum of approximately 1.5"above the top of the cover—the gap over the <br /> cut EIFS will be filled with foam insulation and the new cap flashing will <br /> be adjusted accordingly. <br /> Sign box The existing sign box needs to be removed and the new EIFS system <br /> installed intact at this area. Any reinstallation or new signbox will need to <br /> be mounted on targets on top of the new EIFS system. <br /> We request that the Owner's signage contractor is brought to the table to <br /> establish the remounting requirement. <br /> Canopy flashing and existing • A new through wall drainable flashing will be installed over the <br /> EIFS peak roof condition at the existing canopies. <br /> • We are anticipating that the new roof cladding will be all metal <br /> eliminating the current kalwall materials. <br /> 6264 ELLIS AVE S,SEATTLE,WA 98108 INFO@EVOLUTIONARCHITECTURE.NET <br />