My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6920 SEAWAY BLVD 2019-09-24
>
Address Records
>
SEAWAY BLVD
>
6920
>
6920 SEAWAY BLVD 2019-09-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2019 1:23:35 PM
Creation date
9/24/2019 1:23:09 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6920
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br /> � BATMASTER BACKFLOW PREVENTION ASSEMBLY TEST REPORT <br /> ' (425)397-0275 <br /> WATER PURVEYOR Everett ACCOUNT# <br /> ASSEMBLY ID/FILE#/UTILITY DEVICE# Meter# <br /> NAME OF PREMISE Fluke Building Commercial ❑ Residential ❑ <br /> SERVICE ADDRESS 6920 Seaway Blvd. Everett ZIP 98203 <br /> CONTACT PERSON Dan Cronenwett PHONE (425) 348-1789 <br /> LOCATION OF ASSEMBLY FRONT LEFT CORNER OF BLDG IN VAULT <br /> DOWNSTREAM PROCESS Fire Sprinkler System DCVA ❑ RPBA ❑ PVBA ❑ OTHER DCDA <br /> NEW INSTALL O EXISTING ❑ REPLACEMENT ❑ REMOVED ❑ OLD SER.# <br /> APPROVED ASSEMBLY? YES Eli NO❑ PROPER INSTALLATION?YES [] NO ❑ <br /> MAKE OF ASSEMBLY Watts MODEL 774DCDA SERIAL NO. 1003730416 SIZE 12" <br /> INITIAL DCVA/RPBA PCVA/RPBA BMA F.321/3331/1 <br /> CHECK VALVE NO.I, CHECK VALVE NO.2 AIR INLET <br /> TEST OPENED AT ASID <br /> CLOSED TIGHT E CLOSED TIGHT LI OPENED AT PSID <br /> PASSED LEAKED ii LEAKED ❑ #1 CHECK PSID <br /> FAILED ❑ 2.8 pSID 2.8 PSID <br /> AIR GAP OK? DID NOT OPEN ❑ <br /> CLEAN REPLACE PART CLEAN REPLACE PART CLEAN REPLACE PART CHECK VALVE <br /> NEW ❑ ❑ ❑ ❑ ❑ Cl HELD AT PSID <br /> PARTS ❑ ❑ ❑ ❑ ❑ ❑ LEAKED [] <br /> AND ❑ E7 C7 E7 ❑ <br /> ❑ ❑ ❑ ❑ ❑ Li CLEANED ❑ <br /> REPAIRS REPAIRED ❑ <br /> TEST AFTER CLOSED TIGHT ❑ CLOSED TIGHT ❑ RV EXERCISED ❑ AIR INLET PSID <br /> REPAIRS LEAKED ❑ LEAKED ❑ OPENED AT <br /> PSID <br /> PASSED ❑ <br /> FAILED ❑ PSID PSID #1 CHECK PSID CHIC VALVE PSID <br /> AIR GAP INSPECTION: SUPPLY PIPE DIAMETER SEPARATION PASS ri FAIL 0 <br /> DETECTOR METER READING <br /> LEFT SERVICE AS FOUND Isolation valve: Open [.i] Closed ❑ SOV#1 Open [1 Closed [] SOV#2: Open ❑ Closed [] <br /> REMARKS: <br /> LINE PRESSURE 90 PSI CONFINED SPACE? YES <br /> TESTERS SIGNATURE: 64L--- 4 CERT.NO. B6362 DATE 9/28/2016 <br /> TESTERS NAME PRINTED Adam Aquino TESTERS PHONE# (425)397-0275 <br /> REPAIRED BY: LIC NO. DATE <br /> FINAL TEST BY: CERT. NO. DATE <br /> CALIBRATION DATE 02-24-2016 GAUGE# 03051796 MODEL 845 SERVICE RESTORED YES Li NO [] <br /> I certify that this report is accurate,and I have used WAC 246-290-490 approved test methods and test equipment. <br />