Laserfiche WebLink
Project Info <br />Project Address scheidt invaataant croup <br />Date 1/17/2008 <br />441e Ruckar A... <br />For Building Department Use <br />D�� I •1 <br />T� 0'— <br />Rvarett, Washington <br />Applicant Name: oar,, Parkinson Architects IAA= Clerk/ <br />Applicant Address: 1e11 Colby A...., Rvaratt. Washington <br />Applicant Phone: 1425I252a1s1 <br />Project Description I 0 New Building ❑ Addition ❑ Alteration ❑ Change of Use <br />❑ Prescriptive Q Component Performance ❑ Systems Analysis <br />Compliance Option (See Decision Flowchart (over) for qualification;) <br />Space Heat Type <br />Q Electric resistance Q All other (see over for definitions) <br />Total Glazing Area Electronic version: these values are automatically taken from ENV-UA-I. <br />Glazing Area Calculation <br />(rough opening) Gross Exterior <br />Note: Below grade walls may be included in me <br />(vertical & overhd) divided by Wall Area times 100 equals % Glazing <br />1420.0 -:' 5222.0 X 100 = 27.2% <br />Gross Exterior Wall Area if they are Insulated to <br />the level required for opaque walls. <br />O yes Check here if using this option and If project meets all requirements for the Coocrete/Masenry <br />Concrete/Masonry Option <br />Option. See Decision Flowthan (over) for qualifications Enter requirements for each qualifying <br />10 no assembly below. <br />Envelope Requirements (enter values as applicable) <br />Fully heated/cooled space <br />Minimum Insulation R-values <br />Roots Over Altic <br />N/A <br />All Other Roofs <br />21.0 <br />Opaque Walls' <br />21.0 <br />Below Grade Walls <br />15.0 <br />Floors Over Unconditioned Space <br />30.0 <br />Slabs -on -Grade <br />N/A <br />Radiant Floors <br />N/A <br />Maximum U-/actors <br />Opaque Doors <br />0.290 <br />Vertical Glazing <br />0.750 <br />Overhead Glazing <br />N/A <br />Maximum SHGC (or SC) <br />Vertical/Overhead Glazing <br />NONE <br />Semi -heated space / <br />Minimum Insulation R-values <br />Roofs Over Semi -Healed Spaces° N/A <br />1. Assemblies with metal framing must comply with overall U-factors <br />2. Refer to Section 1310 for qualifications and requirements <br />Notes: <br />Opaque ConcretelMasonry Wall Requirements <br />Wall Maximum U-factor is 0.15 (R5.7 continuous ins) <br />CMU block walls with insulated cores comply <br />If project qualifies for Concrete/Masonry Option, list walls <br />with HC >_ 9.0 Btu/fit•°F below (other walls must meet <br />Opaque Wall requirements). Use descriptions and values <br />from Table 10-9 in the Code. <br />Wall Description U-factor <br />(including insulation R-value & position) <br />Y3 <br />