✓ 6. Please indicate thc ages and the number of children in the new classrooms, nursery, baby and <br />playground arcas in thc northwest comer of the building. Will this area of the building be used during <br />the wcek or only during the Sunday services7 <br />J7. The fcllowship multi-purpose room had been permilted as a classroom. Is this a new revision or are the <br />previously permitted K-12 ciassrooms to remain? <br />�8. "I'he Junior Iligh Youth room has not been prcviously permitted. Please indicate any recisions planned <br />for this roe�i, including the removal of fixed scating and leveling of the floor, similar to the Senior High <br />5 �- <br />The clevator <br />mezzani�e i1� <br />addition to.tt <br />undcr pertnit. <br />� the new second floor is not required by code, per IBC section 1104.4, if the area of the <br />less than 3000 square feet. Plcase clarify the area of the mezzanine, since this is an <br />mez•ranine previously permitted. <br />✓]0. The�st�ctural support of the addition to the mezzanine should include connection details, �Rade and <br />__.�-species of wood, headers, door openings, joist sizes, and structural calculations indicating assumed <br />loads and resistance lo wind, gravity and seismic forces. <br />i-}4Building envelopc calculations are requircd for the office and storage areas, per Chapter 13 of the <br />� WSEC and the R-valucs should be indicated on the drawings at all conditions to meet the selected <br />option of WSEC Tablc 13-1. <br />Upon submission of a permit application and two complete sets of drawings, your application will be processed. <br />Applicable codes include the 200G International Building Code (IBC), the 200G Intemational Fire Code (IFCi, <br />the 200G Intcmational Mechanical Code (IMC), the 2006 Washington State Energy Codc (WSEC}, the 2006 <br />Washington State Ventilation and Indoor Air Quality Code (VIAQ), the 2003 Accessible and Usable f3uildings <br />and Facilitics ICC Al ] 7.1-2003 (ICC Al ] 7.l) and the City of Everett Municipal Code, including Chapter 1G.7G, <br />Automatic Pire Detection and Pire Suppression Systems. All codes referenced, as adopted by the City of <br />Everett, should include currcnt revisions by the Stnte of Washington. These comments address building issues <br />only. Revisions or additions may be required by other departments (such as Utilities, Planning or Fire). <br />All required suUmittals must be of sufficient detail and inforniation to ensure that the proposed structure will be <br />constructed in compliance with all adoptcd codes. You can rcach me directly to discuss this letter b}' e-mail at <br />mhalcy{r�ci.everett.wa.us or Uy phonc at 425-257-8813. <br />c •cl , <br />Meg Naley <br />Plans Gxamin r <br />G�c: Rulh �onzales, Gonzales Design Pariners <br />/� <br />C <br />S Ulllilry\NbrJ�sJU tiv Lman �Inl! 14 y doc <br />