Laserfiche WebLink
� . � <br /> 2006 Wa.' ton State Nonresidential Energy Code Comp' e Form <br /> • � ' � . • <br /> 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 <br /> Decision Flowchart Use this flowchart to determine if project qualifies for the optional Prescriptive Option. <br /> for Prescriptive Option If not,either the Component Performance or Systems Analysis Options must be used. <br /> 1302 Space Heat Type:For the purpose of determining building envelope Electric Resistance:Space heating systems which use electric resistance <br /> requirements,the following two categories comprise all space heating types: � START elements as the primary heating system including baseboard,radiant,and <br /> Other:All other space heating systems inGuding gas,solid fuel,oil,and � ) forced air units where the total electric resistance heat capacity exceeds 1.0 <br /> propane space heating systems and those systems listed in the exception to �� W/ftz of the gross conditioned floor area. Exception:Heat pumps and terminal <br /> electric resistance. (continued at right) � electric resistance heating in variable air volume distribution systems. <br /> ' Electric \ <br /> No -�— �Resistance � — -Yes � � <br /> �-- Heat? — <br /> � All Insulation Installed? ���, / � All Insulation Installed? � <br /> Below Grd Wall(ext) R-10 \/ Wood Metal <br /> Below Grd Wall(oth) R-19 Below Grd Wall(ext) R-10 R-10 <br /> Roof Over Attic R.-30 Below Grd Wall(oth) R-19 U-0.062 <br /> All Other Roof R-21 Roof Over Attic R-38 U-0.031 <br /> Raised Floor R-19 All Other Roof R-30 U-0.034 <br /> Slab-On-Grade R-10 Raised Floor R-30 U-0.029 <br /> Radiant Floor R-10 Slab-On-Grade R-10 R-10 <br /> Opaque Door U-0.60 l Radiant Floor R-10 R-10 <br /> i I Opa I�Door U-0.60 U-0 60 I <br /> -No- Yes-- Yes —No ; <br /> / <br /> � /� <br /> Mass Wall G Wall R1 Mass Wall <br /> NO Criteria OK? �-NO Above Grade Wood,or N Criteria OK? <br /> Wall R19 N� <br /> (below) 0.062 met (below) <br /> � <br /> Yes Yes <br /> � Yes Yis <br /> �G Mass Wall Insulation Req I AG Mass Wall Insulation Req., <br /> Mass Wall U0.15/R5]ci I Mass Wall U0.15/R57ci <br /> �CMU Block Ins.Cores YeS CMU Block Ins.Cores <br /> Wood Frame R19 Wood Frame R19 <br /> Metal Framed R19 rES � Metal Framed U0.062 <br /> � I Glazing Criteria Met7 � � Glazing Criteria Met? I NO <br /> No <br /> Glazing Vert OH Glazing Vert OH I <br /> Area% UVaI UVaI SHGC Area% UVaI UVaI SHGC <br /> 0-30% 0.55 0.70 0.45 i 0-30% 0.40 0.60 0.40 <br /> '30-45% 0.45 0.60 0.40 ', >30 Not Allowed <br /> >45% Not Allowed -- --- i <br /> N� Yles � Prescriptive , Yes No <br /> � Path Allowed <br /> � Component Performance, I <br /> — -� Systems Analysis, or t --- - <br /> EnvStd Required <br /> Concrete/Mason Option* Wall Heat Capacity (HC) 'Ifthearea <br /> weighted heat <br /> Assembly Description Assy.Tag HC"" Area(sfl HC x Area capacity(HC)of <br /> the total above <br /> grade wall is a <br /> minimum of 9.0, <br /> the Concrete <br /> Masonry Option <br /> may be used. <br /> "For framed <br /> walls,assume <br /> HC=1.0 unless <br /> calculations are <br /> provided;for all <br /> other walls, use <br /> Section 1009. <br /> Totals <br /> Area weighted HC:divide total of(HC x area)by Total Area <br />