My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1310 SE EVERETT MALL WAY Geotech Report 2022-10-25
>
Address Records
>
SE EVERETT MALL WAY
>
1310
>
Geotech Report
>
1310 SE EVERETT MALL WAY Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:48:34 AM
Creation date
10/14/2019 8:43:55 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1310
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2006 Wa ton State Nonresidential Energ Code Comp� e Form <br /> � • • ' • <br /> 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 <br /> Project Address sE Everett r�ii way, Everett, wr. Date 4/4/2013 <br /> The�ollowin�information js neGes ary to�heck a building permit application for compliance with the building envelope requirements in the <br /> Was ington tate Nonresidential�nergy ode. <br /> Applicability Code Location Building Department <br /> (yes, no, n.a.) Section Component Information Required on Plans Notes <br /> GENERAL REQUIREMENTS (Sections 1301-1314) <br /> 1301 Sco e Unconditioned s aces identified on lans if allowed <br /> yes 1302 Space heat type: <br /> Other If"Other', AC-1 <br /> indicate on lans that electric resistance heat is not allowed <br /> 1310.2 Semi-heated spaces Semi-heated spaces identified on plans if allowed <br /> 1311 Insulation <br /> yes 1311.1 Insul.installation Indicate densities and clearances <br /> yes 1311.2 Roof/ceiling insul. Indicate R-value on roof sections for attics and other roofs; A-6/3 <br /> Indicate clearances for attic insulation; <br /> Indicate baffles if eave vents installed. <br /> Indicate face sta lin of faced batts <br /> yes 1311.3 Wall insulation Indicate R-value on wall sections; A-6/3 <br /> Indicate face stapling of faced batts; <br /> Indicate above grade exterior insulation is protected; <br /> Indicate loose-fill core insulation for masonry walls as necess; <br /> Indicate heat capacity of masonry walls <br /> if mason o tion is used F73 <br /> 1311.4 Floor insulation Indicate R-value on floor sections; N/A <br /> Indicate substantial contact with surface; <br /> Indicate supports not more than 24"o.c.; <br /> Indicate that insulation does not block <br /> airFlow throu h foundation vents <br /> no 1311.5 Slab-on-grade floor Indicate R-value on wall section or foundation detail; <br /> Indicate slab insulation extends down vertically 24"from top; <br /> Indicate above rade exterior insulation is rotected <br /> 1311.6 Radiant floor Indicate R-value on wall section or foundation detail; <br /> Indicate slab insulation extends down vertically 36"from the top; <br /> Indicate above grade exterior insulation is protected; <br /> Indicate insulation also under entire slab where re 'd.b Official <br /> 1312 Glazing and doors Provide calculation of glazing area(including both vertical <br /> vertical and overhead as ercent of ross wall area <br /> 1312.1 U-factors Indicate glazing and door U-factors on glazing and door <br /> schedule(provide area-weighted calculations as necessary); <br /> Indicate if values are NFRC or default,if vatues are default <br /> then specify frame type,glazing layers,gapwidth,low-e <br /> coatin s as fillin s <br /> 1312.2 SHGC&SC Indicate glazing solar heat gain coeffcient or shading <br /> coefficient on glazing schedule(provide area-weighted <br /> calculations as necessa <br /> 1313 Moisture control <br /> 1313.1 Vapor retarders Indicate vapor retarders on warm side <br /> 1313.2 Roof/ceiling vap.ret. Indicate vapor retarder on roof section; <br /> Indicate va .retard.with sealed seams for non-wood struc. <br /> 1313.3 Wall vapor retarder Indicate vapor retarder on wall section <br /> 1313.4 Floor vapor retarder Indicate vapor retarder on floor section <br /> 1313.5 Crawl space vap.ret. Indicate six mil black poiyethylene overlapped 12"on ground <br /> 1314 Air leakage <br /> 1314.1 Bldg.envel.sealing Indicate sealing,caulking,gasketing,and weatherstripping <br /> 1314.2 Glazing/door sealing Indicate weatherstripping <br /> 1314.3 Assemb.as ducts Indicate sealing,caulking and gasketing <br /> 1314.4 Recessed Lighting Fixtur Indicate IC rating,ASTM E283 certification,and gasketing or caulking to <br /> ceiling <br /> PRESCRIPTIVE/COMPONENT PERFORMANCE (Sections 1320-23 or 1330-34) <br /> Envelope Sum Form Completed and attached. <br /> Provide component performance worksheet if necessary <br /> If"no"is shown for any question, provide explanation: / <br /> / <br /> � � <br /> /� <br /> �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.