Laserfiche WebLink
TARG ETo <br /> 1000 NICOLLET MALL <br /> MINNEAPOLIS, MN 55403 <br /> .�. �.��-� 1 ����`� �� � I �°�I � � �.� <br /> www.ctagroup.com <br /> Date No. Description <br /> 02/06/18 PERMIT ISSUE <br /> i <br /> i <br /> � <br /> , <br /> 1 <br /> , <br /> ,�::-�=���,,���� <br /> ;��`�.�� �,�w�s�,�``����'' <br /> �A�ryJ�� � �����r�i <br /> , <br /> °�;-�'•^r� q' <br /> �s � �:�, �� <br /> � <br /> � ��� � <br /> 34630 <br /> 'o'�'����''i� p <br /> €�N P <br /> 5�� <br /> HVAC EQUIPMENT RESPONSIBILITY MATRIX <br /> DISCHARGE& <br /> ELECTRICAL EQUIPMENT FURNISH EMS INSTALL EMS EMS CABLE SPACE TEMP ANDIOR RETURN TEMP DELIVERY SCHEDULE EMS CONTROL <br /> EQUIPMENT SPECIFIED MFR FURNISH BY INSTALL BY CONNECTION START UP CABLE CABLE TERMINATION SMOKE DETECTOR HUMIDITY SENSOR SENSOR COORDINATION HARDWARE TESTING&BALANCING OF EQUIPMENT <br /> TRANSFER FAN TF-3 GREENHECK MECH MECH ELEC MECH NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED NOT REQUIRED MECH NOT REQUIRED CONTRACTOR'S BALANCING CONTRACTOR, SEE SPECIFICATIONS FOR APPROVED VENDORS <br /> 1. HVAG START UP IS BY MECHANICAL CONTRACTOR. FINAL ACCEPTANCE CHECK BY OWNER'S SERVICE CONTRACTOR PRIOR TO TURNOVER. <br /> 2. TARGET OWNER'S SITE REPRESENTATIVE TO CONTACT TEST AND BALANCE CONTRACTOR ASSIGNED TO STORE TO SCHEDULE BALANCING OF MECHANICAL SYSTEMS A MINIMUM OF TWO WEEKS PRIOR TO BALANCING. <br /> 3. TARGET OWNER'S SITE REPRESENTATIVE TO CONTACT OWNER'S ENERGY MANAGEMENT SYSTEM (EMS)CONTRACTOR TO VERIFY LENGTHS OF EMS CABLE REQUIRED AND TO SCHEDULE TERMINATIONS OF ALL EMS CABLE, INSTALLATION OF TEMPERATURE <br /> SENSORS AND COMMISSIONING OF EMS SYSTEM A MINIMUM OF TWO WEEKS PRIOR TO DATE NEEDED. <br /> GRILLES, REGISTERS & DIFFUSERS SCHEDULE - OWNER FURNISHED M7 � <br /> VOLUME � <br /> TYPE SERVICE MAKE MODEL DAMPER FRAME FINISH MATERIAL REMARKS Project Phase � <br /> C CEILING DIFFUSER TUTTLE AND S1200-LT-WH --- NOTE 1 WHITE ENAMEL STEEL 24"x24"MODULAR FULL-FACE DIFFUSER WITH ROUND NECK _ � � <br /> BAILEY . � O <br /> F RETURN/TRANSFER TUTTLE AND CRE500-SF-02-WH --- NOTE 1 WHITE ENAMEL ALUMINUM SEE PLAN FOR FACE SIZE; 1/2"x1/2"x1/2"EGGCRATE GRID.AVAILABLE FACE SIZES ARE 24"x6",24"x12",24"x24"&24"x48" N <br /> GRILLE BAILEY � � <br /> K LINEAR SLOT DIFFUSER TUTTLE AND AIR-TRAC-CTL-01-001-WH --- 1 WHITE ENAMEL ALUMINUM ONE SLOT,48"LONG, INSULATED FACTORY PLENUM.SEE PLAN FOR INLET SIZE AND SLOT WIDTH. PATTERN CONTROLLER ADJUSTED FOR VERTICAL THROW. <br /> BAILEY � � <br /> N SUPPLY REGISTER TUTTLE AND T60-SF-01-SOBD-WH OPPOSED BLADE NOTE 1 WHITE ENAMEL STEEL 24"x6"FACE; 3/4"BLADE SPACING, SINGLE DEFLECTION WITH BI-DIRECTIONAL THROW, BLADES PARALLEL TO THE SHORT DIMENSION. BLADE ANGLE IS FIXED AT 22.5°. ^ <br /> BAILEY � � � <br /> ALL GRILLES; REGISTERS&DIFFUSERS ARE FURNISHED BY OWNER AND INSTALLED BY MECHANICAL CONTRACTOR. QUANTITIES, SIZES AND DELIVERY DATES SHALL BE COORDINATED THROUGH THE TARGET REPRESENTATIVE AT 1-866-667-4822. � � � <br /> 1. PROVIDE LAY-IN FRAME TYPE. � ^ <br /> � N � <br /> TRANSFER FAN SCHEDULE �W � <br /> WHEEL ELECTRICAL � W <br /> AIRFLO TSP DIAMETER ROOF FREQUENC � � � <br /> EQUIP NO AREA SERVED MANUFACTURER MODEL W(CFM) ("WG) (IN) RPM DRIVE OPENING DAMPER SIZE HP VOLTAGE PHASE Y REMARKS W W <br /> TF 3 EQUIPMENT GREENHECK SQ-65 140 0.125 7" 1300 DIRECT N/A N/A 0.166 120 1 60 PROVIDE T-STAT \ t , ' � <br /> STORAGE 213 <br /> L.LJ <br /> W � � <br /> � <br /> � <br /> ROD HANGER � <br /> — STRAP HANGER <br /> BAR JOIST OR —� <br /> STEEL BEAM <br /> TYPICAL <br /> STEEL ANGLE --------� <br /> DUCT WIDTHS_� SCREW STRAP TO <br /> DUCT WIDTHS LESS THAN 36" DUCT. MINIMUM <br /> 36"OR GREATER 1"STRAP LENGTH <br /> PRE-PUNCHED CHANNEL ON UNDERSIDE <br /> SUPPORT FASTENED TO OF DUCT. <br /> ROOF DECK TOP OF BAR JOIST. <br /> CONICAL SPIN IN TYPICAL � TYPICAL. <br /> O7 SALES FLOOR GRILLES AND REGISTER SQUARE TO ROUND PROVIDE SUPPORTS WITH DAMPER <br /> ADAPTERS PROVIDED BY OWNER,ALL OTHERS TO BE TO PREVENT SAG <br /> CONTRACTOR PROVIDED. BETWEEN HANGERS Project Number T 0 3 3 7 <br /> � SUPPLY DUCT <br /> MAIN STRAP HANGER ROD HANGER OR <br /> SEE PLANS FOR SEE PLANS FOR HARD DUCT STRAP HANGER <br /> NECK SIZE PI"OtO: P�$$ Version: N/A Config: N/A <br /> NECK SIZE ELBOW I BAND SAME SIZE -------� Drawn By R R <br /> � AS STRAP <br /> TOTAL FLEX DUCT HANGER 36"MAXIMUM y MA <br /> LENGTH SHALL NOT DUCT DIAMETER GREATER THAN Checked B <br /> EXCEED 6 FEET 36"DUCT DIAMETER <br /> GENERAL NOTES: <br /> GRILLE OR � A. REFER TO"SMACNA HVAC DUCT CONSTRUCTION STANDARDS" FOR HANGER REQUIREMENTS, <br /> REGISTER GRILLE OR MINIMUM OF ONE DUCT DIAMETER INCLUDING SIZES OF STRAP HANGERS, ROD HANGERS, STEELANGLESAND FASTENERS. M EC HAN I CAL. <br /> BELOW REGISTER <br /> 12x12,24x24 OR BELOW DUCT COLLAR OF STRAIGHT DUCT TO INLET OF B. SUPPORT FROM BAR JOIST TOP CHORD PANEL POINT. <br /> 24"x48"(18"x30"NECK) 6x24 OR 12x24 DIFFUSER, OR PROVIDE EQUALIZING C. MAXIMUM LOAD ON ANY PANEL IS 100 LBS, UNLESS APPROVED BY STRUCTURAL S C H E D U L E S & <br /> CONNECTING GRID AT DIFFUSER ENGINEER. SEE STRUCTURAL FOR ADDITIONAL REQUIREMENTS. <br /> NOTE: STRAP D. SEE 5/M501 FOR SEISMIC BRACING DETAIL. D ETA I L S <br /> MAXIMUM OF 18"OF FLEX DUCT MAY BE USED FOR FINAL CONNECTION. SALES FLOOR DIFFUSER � <br /> BOOTS ARE OWNER PROVIDED,ALL OTHERS ARE CONTRACTOR PROVIDED. E. DO NOT INSTALL DUCTWORK CLOSER THAN 8"TO ANY WATER, FIRE PROTECTION,OR <br /> GAS PIPING. <br /> � <br /> � GRILLE & REGISTER BOOT 2 DIFFUSER FLEXIBLE DUCT CONNECTION 3 DUCT HANGERS <br /> M601 SCALE: NOT TO SCALE M601 SCALE: NOT TO SCALE M601 SCALE: NOT TO SCALE <br /> 2/5/2018 10:55:25 AM <br /> � � � . � . � � � � � � . � � � � � � � � � � �,-: � <br /> t � .,.;�_ �..�-::: t � t � <br /> . . _ . .. <br /> •�. -�.� .�. <br /> . �.. . ,,�Y_ . . <br /> ,.. � .., . ,. . . . . . . -,^rt . ��>., . .,:. . . r�=< <br /> , . <br /> . . . 'F.";: . ,� . ..: .:k': � "� . - .C•0t � . . � .A',' . . ... .P,'.. � `� . ' . :' 'P`i ^rc.: .A.':t ^C."< �."i�'; 1s"='„ . 1P�'„ . :^r'�`.t cF'. '�fi-; . . <br /> ,:;; ..� .,,,..n. , . �. . <br /> . .r " " s _ . ' _.... . .. " . .' . ., " . s . .r . .r <br /> . . . �'.��� .. ... . . . . .. :,. . . . _ . ._ . . . �v . .,. . . �- . ... . .� . . . . . . . . . . . . . .� . . . . . . . . . .. . . . . . _ _ _ . . . . .. . . _ . . <br /> ._ .. . ^;, �.. . . <br /> -., <br /> , . <br /> .�. . .. . . ... ... . . . . ... . .. . .. . ._ . .. �'. .. ' . .� . . . . . .. . . . .. . .. . . . . . . . . <br /> _ <br /> . . . . . . . . . . . ��. .. . �.' <br />