ElectricalSheetlndex ELECTRICAL SYMBOL LIST GENERAL NOTES
<br /> Sheet Number Sheet Name ❑ '
<br /> E001 ELECTRICAL SYMBOL LIST KEY NOTE WATERFLOW SWITCH A. MATERIALS, PRODUCTS, DEVICES, FIXTURES,FORMS OR TYPES
<br /> � OF CONSTRUCTION INCLUDED IN THESE SPECIFICATIONS SHALL
<br /> ED111 LIGHTING DEMOLITION PLAN DESIGNATES OWNER SUPPLIED EQUIPMENT. MEET OR EXCEED THE REQUIREMENTS OF NATIONAL
<br /> ED211 POWER&SYSTEMS DEMOLITION PLAN O REFER TO SHEET A601 FOR OWNER FURNISHED o-O TAMPER VALVE SWITCH ELECTRICAL CODE(NEC),AMERICAN NATIONAL STANDARD '
<br /> E111 LIGHTING PLAN EQUIPMENT SCHEDULE. INSTITUTE(ANSI), INSTITUTE OF ELECTRICAL AND ELECTRONICS I_
<br /> E121 SPECIALTY LIGHTING PLAN � O DOOR HOLDER ENGINEERS(IEEE)AND NATIONAL ELECTRICAL MANUFACTURING =
<br /> MULTIPLE SYMBOLS ON BRACKET INDICATE ASSOCIATION(NEMA).
<br /> E124 TRACK LIGHTING PLAN ALL DEVICES UNDER ONE COVER PLATE. � BELL-90"AFF UNO TA R G E TOO I
<br /> E131 ENTRY&GUEST SERVICES LIGHTING PLANS INCANDESCENT,HID,CFL OR LED LUMINAIRE B. MATERIALS AND EQUIPMENT SHALL BE LISTED AND APPROVED BY
<br /> E141 OFFICE LIGHTING PLANS � O �-a/ BUZZER-90"AFF UNO A NATIONALLY RECOGNIZED INDEPENDENT TESTING
<br /> E151 GROCERY&ADULT BEVERAGE LIGHTING PLANS � LABORATORY AS CONFORMING TO THEIR STANDARDS. �OOO NI COLLET MALL
<br /> E161 OCCUPANCY SENSORS LED LUMINAIRE MINNEAPOLIS, MN 55403
<br /> E211 POWER AND SYSTEMS PLANS � � � � FLUORESCENT LUMINAIRE � SPEAKER-CEILING FLUSH MOUNT C. WIRE,CABLES,AND INSULATIONS SHALL CONFORM TO ICEA-
<br /> NEMA AND NATIONAL ELECTRICAL CODE STANDARDS AND
<br /> E311 ENTRY,CHECKLANES&GUEST SERVICES POWER&SYSTEMS PLAN 0 CONTROL PANEL SPECIFICATIONS. USE NEW WIRE AND DELIVER TO THE JOB SITE
<br /> E321 OFFICE POWER&SYSTEMS PLANS � TRACK LIGHT IN COILS OR ON REELS. EACH COILIOR REEL SHALL HAVE A
<br /> E355 ELECTRICAL DISTRIBUTION CENTER PLANS LABEL WITH THE MANUFACTURER'S NAME,TRADE NAME OF WIRE,
<br /> E381 ELECTRONICS&ENTERTAINMENT POWER&SYSTEMS PLANS � INDICATES EMERGENCY LIGHTING � LP PANELBOARD SIZE OF WIRE AND UL LABEL.
<br /> E385 BEAUTY ELECTRICAL PLANS
<br /> E401 MARKET AREA POWER&SYSTEMS PLAN ILLUMINATED EXIT SI�N-CEILING/WALL(SHADED � HL PANELBOARD D. ALL ELECTRICAL EQUIPMENT AND WIRING SHALL BE LISTED AND
<br /> E501 ELEVATIONS&CONTROL DIAGRAMS
<br /> � ��, QUADRANT INDICATES FACE(S). PROVIDE LABELED BY AN APPROVED AGENCY. INSTALLATION SHALL BE IN
<br /> E511 DETAILS&WIRING DIAGRAM � DIRECTIONAL ARROWS WHERE INDICATED. � HP&LD PANELBOARD ACCORDANCE WITH APPROVED LISTING.
<br /> E521 ELECTRICAL DETAILS
<br /> E531 ELECTRICAL DETAILS �� POLE MOUNTED LUMINAIRE � TRANSFORMER
<br /> E541 ELECTRICAL DETAILS � ��-�� ������ �� � � � � �- �-�
<br /> I-�J WALL MOUNT JUNCTION BOX-18"AFF UNO � MAGNETIC MOTOR STARTER
<br /> E601 EQUIPMENT AND LIGHT FIXTURE SCHEDULE OR CABINET MOUNT JUNCTION BOX
<br /> E611 ELECTRICAL ONE-LINE DIAGRAM � SAFETY SWITCH(POLES NOTED, F INDICATES
<br /> E621 PANELBOARD SCHEDULES FUSED, SIZE AS NOTED. www.ctagroup.com
<br /> E622 PANELBOARD SCHEDULES JO CEILING MOUNT JUNCTION BOX )
<br /> A = VIDEO DISTRIBUTION SYSTEM
<br /> E901 SPRINKLER SUPERVISORY SYMBOL LIST, POINT LIST&SITE PLAN CRT = NETWORK SYSTEM � COMBINATION STARTER/SAFETY SWITCH
<br /> E911 SPRINKLER SUPERVISORY INITIATING DEVICE PLANS E = ELECTRONIC POINT OF SALE(EPOS)SYSTEM
<br /> E921 SPRINKLER SUPERVISORY SIGNALING DEVICE PLAN F = FIRE ALARM SYSTEM . PUSH BUTTON STATION
<br /> P = PAGING SYSTEM �
<br /> E931 FIRE ALARM RISER DIAGRAM S = SECURITY SYSTEM
<br /> E932 BATTERY CALCULATIONS T = LOW VOLTAGE THERMOSTAT-96"AFF UNO � MOTOR CONNECTION
<br /> E941 ALARM INSTALLATION DETAILS V1 = SINGLE'F'CONNECTOR VIDEO DIST.
<br /> E951 INTRUSION SYMBOLS&POINTS LIST COVERPLATE
<br /> V2 = DUPLEX'F'CONNECTOR VIDEO DIST. O DAMPER MOTOR
<br /> E961 INTRUSION SYSTEM STORE PLAN
<br /> COVERPLATE
<br /> E971 INTRUSION SYSTEM AREA PLANS OS = OCCUPANCY MOTION SENSOR SWITCH � LINE VOLTAGE THERMOSTAT-48"AFF UNO
<br /> H = DOOR HOLDER T
<br /> E981 SYSTEM WIRING DETAILS PS = PHOTO SENSOR
<br /> E982 INSTALLATION DETAILS TS TEMPERATURE SENSOR,96"AFF UNO
<br /> �"' SINGLE RECEPTACLE-18"AFF UNO
<br /> RS R-NET SENSOR,48"AFF UNO
<br /> @� DUPLEX RECEPTACLE-18"AFF UNO
<br /> (SSR-DENOTES SURGE SUPPRESSION) WIRING METHOD AND IDENTIFICATION(NOTE:WITHOUT
<br /> (GFCI-GROUND FAULT INTERRUPTER) � FURTHER IDENTIFICATION SYMBOL INDICATES 1/2"CONDUIT
<br /> (WP-WEATHER PROOF W/WHILE IN USE COVER) WITH 2#12 AWG CONDUCTORS.CROSS LINES INDICATE
<br /> QUANTITY OF#12 AWG CONDUCTORS AND EXTENDED
<br /> � QUADRUPLEX RECEPTACLE-18"AFF UNO CROSS LINE INDICATES NEUTRAL CONDUCTOR,
<br /> LETTER"G"INDICATES SEPARATE GROUND(GROUND NOT SHOWN BY
<br /> Room Names&Numbers � OPTIONAL/EMERGENCY RECEPTACLE-18"AFF UNO CROSS LINE),ALL IN CODE SIZED CONDUIT Date N�. Description
<br /> Number Name CONDUIT CONCEALED IN CEILING OR WALL 02/06/18 PERMIT ISSUE
<br /> 101 ENTRY � OPTIONALIUPS RECEPTACLE-18"AFF UNO
<br /> 102 SALES — _
<br /> 103 GUEST SERVICES B-� SPECIAL-PURPOSE RECEPTACLE-18"AFF UNO � � � � CONDUIT CONCEALED IN FLOOR
<br /> 103A FLEX FULFILLMENT CONDUIT EXPOSED
<br /> 104 CIRCULATION � SPLIT WIRE RECEPTACLE-18"AFF UNO
<br /> 104A CASH OFFICE
<br /> 105 FITTING ROOMS �PS� MULTIOUTLET ASSEMBLY,ARROWS DEFINE THE - - CONDUIT RUN UNDERGROUND(SLOPE TO DRAIN
<br /> 105A RESHOP LIMITS OF THE INSTALLATION.
<br /> TO PULL BOXES).
<br /> 105B FITTING ROOM LOUNGE RECEPTACLES 12"OC UNO
<br /> 107 CIRCULATION CONDUIT TURNED UP
<br /> 108 STAIR B � CLOCK HANGER RECEPTACLE-84"AFF UNO
<br /> 109 STAIR A CONDUIT TURNED DOWN
<br /> 110 BAG STORAGE �A FLOOR BOX SYSTEMS(LETTER DENOTES OUTLET
<br /> 111 STORAGE TYPE,SEE DETAILS) CONDUIT CAPPED OR BUSHED
<br /> 112 COFFEE SALES
<br /> 113 COFFEE STORAGE � POWER POLE-LETTER DENOTES TYPE
<br /> (a-1) -NUMBER DENOTES PRE MANUFACTURED B�NCH CIRCUIT HOME RUN TO PANELBOARD
<br /> 114 CONTROL ROOM CABLE KIT TYPE LP-1 (UPPER CODE-PANEL ID, LOWER NUMERALS
<br /> 115 WOMEN �,2,3 IDENTIFY CIRCUIT NUMBERS)
<br /> 116 MEN � SINGLE-POLE SINGLE-THROW SWITCH-44"AFF UNO �
<br /> 117 CIRCULATION DEVICE WITH PANELlCIRCUIT INDICATOR
<br /> 118 AP OFFICE � 2 TWO-POLE SINGLE-THROW SWITCH-44"AFF UNO 2#01
G AND SPECIAL WIRING REQUIREMENTS NOTED
<br /> 119 JANITOR
<br /> 121 CIRCULATION � 3 THREE-WAY SWITCH-44"AFF UNO G EQUIPMENT GROUND
<br /> 122 STOCK
<br /> 122 COFFEE SEATING �4 FOUR-WAY SWITCH-44"AFF UNO � GROUND CONNECTION AS NOTED
<br /> 122.A ELECTRICAL � SWITCH AND PILOT LIGHT-44"AFF UNO �'-'--
<br /> 125 ELECTRONICS STOCK P NOTE: PILOT LIGHT IS ON WHEN SWITCH IS ON i� � LOW VOLTAGE CABLE
<br /> 126 PHARMACY
<br /> 127 PHARMACY RESTROOM �K KEY-OPERATED SWITCH-44"AFF UNO EXISTING TO REMAIN
<br /> 128 PHARMACY STORAGE M = MOMENTARY CONTACT,SPDT
<br /> 130 COMPACTOR I BALER HOA= HAND-OFF-AUTO SWITCH --------- EXISTING TO BE DEMOLISHED
<br /> SC = SPEED CONTROL
<br /> 131 RECEIVING MSS= MOTOR STARTER SWITCH
<br /> 132 CIRCULATION OS = OCCUPANCY(MOTION)SENSOR SWITCH NEW DEVICE
<br /> 133 MARKING D = DIMMER SWITCH(WATTAGE AS NOTED.)
<br /> 134 WATER SERVICE ���h INDICATES EXISTING DEVICE TO REMAIN
<br /> ►� TELEPHONE OUTLET-18"AFF UNO
<br /> 137 STOCK ROOM WITH 3/4"EMPTY CONDUIT TO ABOVE '�' SYMBOL WITH SLAHES,OR SHOWN DASHED,OR KEYNOTED:
<br /> 138 ELECTRICAL SUSPENDED CEILING OR TO JOIST SPACE INDICATES EXISTING DEVICE TO BE DEMOLISHED AND/OR RELOCATED
<br /> 139 NIGHT MAINT IN UNFINISHED SPACES. � R SYMBOLS SHOWN WITH LETTER"R"INDICATES RELOCATED DEVICE
<br /> 140 DAY MAINT
<br /> 142 FIXTURE STORAGE W H TELEPHONE OUTLET-44"AFF UNO �� SYMBOLS SHOWN WITH STANDARD TEXT INDICATES NEW DEVICE
<br /> 143 WOMEN WITH 3l4"EMPTY CONDUIT TO ABOVE
<br /> SUSPENDED CEILING OR TO JOIST SPACE
<br /> 143A MEN JUNCTION BOX NO CLOSER THAN 4"FROM � `�`"��
<br /> ���J-�:. EXISTING CONDUIT TO BE DEMOLISHED
<br /> 146 ELECTRONICS STOCK FINISHED DOOR FRAMEIN UNFINISHED SPACES.
<br /> 147 STOC K
<br /> 149 STOCK D-� DATA OUTLET-18"UNO WITH 3/4"EMPTY
<br /> 180 DAIRY COOLER CONDUIT TO ABOVE SUSPENDED CEIL�NG OR X-INDICATES TRACK CROSSOVER ,���'o L Syljf
<br /> 181 FREEZER TO JOIST SPACE IN UNFINISHED SPACES. - C
<br /> 182 MEAT COOLER y �°2�
<br /> 183 PRODUCE COOLER D►-� TELEPHONE&DATA OUTLET-18"UNO WITH X
<br /> 3/4"EMPTY CONDUIT TO ABOVE SUSPENDED T2-X T2-X=WHERE X INDICATES TRACK LENGTH IN FEET I
<br /> 184 DRY PRODUCE/LABELING ROOM CEILING OR TO JOIST SPACE IN UNFINISHED �
<br /> 185 VACUUM PUMP ROOM SPACES. R�tio
<br /> 200 CI RC U LAT I ON _"J�oN
<br /> 201 ETLS&TLS NOTE:DIMENSIONS ARE TO CENTERLINE OF DEVICE OR BOX UNO.
<br /> 202 TRAINING T=INDICATES TRACK"T"
<br /> 203 LOUNGE
<br /> 204 CONFERENCE T Date of Signature: 02/05/2018
<br /> 205 CONFERENCE
<br /> 206 CONFERENCE T2-X T2-X=WHERE X INDICATES TRACK LENGTH IN FEET
<br /> 207 ETL-HR
<br /> 208 STL
<br /> . 209 ELECTRICAL ,
<br /> 211 TMSC r L=INDICATES TRACK"L°
<br /> 212 STORAGE I �
<br /> 213 STORAGE �
<br /> 214 STORAGE �
<br /> 215 STORAGE T2-X T2-X=WHERE X INDICATES TRACK LENGTH IN FEET
<br /> 216 STORAGE
<br /> 217 LOCKERS �
<br /> �
<br /> W
<br /> �
<br /> W -
<br /> Q �
<br /> W
<br /> �
<br /> ^ Q
<br /> �— � o0
<br /> ~ J N
<br /> W Q �O
<br /> L.L_ � �
<br /> W �-
<br /> / ~
<br /> W
<br /> W �
<br /> L1J
<br /> � .
<br /> W
<br /> W
<br /> Cn
<br /> �
<br /> _ O
<br /> d'
<br /> Project Number T�0 3 3 7
<br /> Proto:P188 Version:N/A Config:RR
<br /> Drawn By �LS
<br /> Checked By TK
<br /> CONSULTANT QUALITY ASSURANCE REVIEW '
<br /> - ELECTRICAL
<br /> DOCUMENTS REVIEWED BY: TROY KINKADE SYM B O L L I ST
<br /> REVIEWERS PHONE: 208.577.5659
<br /> DATE REVIEWED: 01/30/2018
<br /> MODEL QUALITY REVIEWED BY: JAMES SANDERSON
<br /> REVIEWERS PHONE: 208.577.5635
<br /> DATE REVIEWED: 01/24(2018
<br /> 2/5/2018 11:41:10 AM
<br /> . . .. . . . . , . . .. . . . . . . . . . _ . . . . . . . . . .
<br /> ... ,
<br /> . w,Y,; ..: . ,;;�._ �,: , ,.. . . , _ . . � ,.Y;; . ; _.ri:, , t -.nY.. , t t
<br /> . . • ,.-. . .,,�:. . . .�:,,.. �Y,.,
<br /> . . . . _ . . : _ . ; . - . ,. . . �.
<br /> . . . ,:: . . . . . . . ..:,... . . . w:. :�:x-_
<br /> . . . . . . . . . . . . . . , . . . . . - : . . .
<br /> . . ..e.. .,tr. . .f,, . .� . . ..C.' . , �..�; . . ,z; . .� . .f . .� . ..� .F .A'. . .� . .�-. � 'P3� � '�•.,; � ..r,",< � . '�°;'.. � 'Pai. � .,.�,.;,. .
<br /> , . �.� . ... . . , . , . . . ,. . , ... . . .. . �-� . .. . .� .. . . -� . .,.. . . ., . ,�.. .. . .� . . �- . . .. . . .. . . . . . . . . .. . . . _ . . . . . . . .. . . . . . . . . .. . . . .. . . . . . . . . _ . .. . . .
<br /> P f�
<br />
|