Laserfiche WebLink
EXISTING PROTECTION CRITERIA FIRE SPRINKLER SYMBOL LEGEND <br /> OCCUPANCY HOSE MAXIMUM SPRiNKLER TOTAL NEW SPRINKLERS REQUIRED 7 CONTRACTOR-PROVIDED FIRE SPRINKLERS <br /> CLASSIFICATION DENSITY ALLOWANCE SPACING DESIGN BASIS TOTAL <br /> (GPM) (SQ FT) SYMBOL DESCRIPTION SYMBOL SIZE MFR MAKE S.I.N. FINISH STYLE TEMP K-FACTOR �ENTIRE BUILDING) <br /> CORRIDORS/TENANT SPACES/GROCERY PREP/FOOD TENANT/OFFICES 0.20/1500 SQ FT 250 130 EXISTING DESIGN DENSITY ------ EXISTING BRANCH LINE � 1/2" TYCO TY-FRB TY3231 WHITE RECESSED 155 5.6 4 <br /> (MISCELLANEOUS STORAGE) STYLE 15 <br /> ENTRY VESTIBULES (ORDINARY HAZARD GROUP 2) MINIMUM 0.20/1500 SQ FT 250 130 EXISTING DESIGN DENSITY ------ EXISTING SPRINKLER MAIN � 1/2" TYCO TY-B TY3251 BRASS INTER. 200 5.6 1 <br /> OR ENTIRE AREA PENDENT <br /> COOLERS/FREEZERS (MISCELLANEOUS STORAGE) MINIMUM 0.20/1500 SQ FT 250 130 EXISTING DESIGN DENSITY NEW SPRINKLER BRANCH LINE Q 1" TYCO DS-C TY3555 WHITE/ CONCEAL 200 5.6 1 <br /> OR ENTIRE AREA CHROME C Y N T E R G Y <br /> RESTROOMS/BREAKROOMS (LIGHT HAZARD) 0.10/1500 SQ FT 100 225 EXISTING DESIGN DENSITY NEW SPRINKLER MAIN � 1/2" TYCO TY-FRB TY3231 BRASS PENDENT 200 5.6 � CYNTERGY ENGINEERING,P��c <br /> 810 S CINCINNATI <br /> HYDRAULIC REFERENCE POINT: REFER TO EXISTING FIRE SPRINKLERS TO REMAIN (UNLESS NOTED OTHERWISE) CONTRACTOR SHALL SECOND FLOOR <br /> 51 "" DESIGN DRAWINGS FOR EXACT LOCATIONS FIELD VERIFY TULSA,OK 74119 <br /> 918.877.6000 <br /> m EXISTING SPRINKLER RISER SYMBOL SIZE MFR MAKE S.I.N. FINISH STYLE TEMP K-FACTOR --- ��cyntergy.com <br /> C-- EXISTING CAP �? 1/2" --- --- --- WHITE RECESSED 155 5.6 <br /> STYLE 10 STIPULATION FOR REUSE <br /> [- NEW CAP <,�j ��Z" --- --- --- BRASS HSW ZOO �J.F> THIS DRAWING WAS PREPARED FOR <br /> USE ON A SPECIFIC SITE AT EVERETT <br /> 13 NEW TEE �� WHITE/ irs� ISSUE DATE ONR04/09%8, A D IT <br /> � � CHROME CONCEAL 200 S.F) --- IS NOT SUITABLE FOR USE ON a <br /> DIFFERENT PROJECT SITE OR AT A <br /> SHIELD� --- LATER 11ME. USE OF THIS DRAWING <br /> � NEW ELL LJ 3/4" --- --- --- BRASS HEAD 155 8.O FOR REFERENCE OR EXAMPLE ON <br /> GUARD ANOTHER PROJECT REQUIRES THE <br /> SERVICES OF PROPERLY LICENSED <br /> o �- NEW INSPECTOR'S TEST/AUXILIARY EXISTING FIRE SPRINKLERS TO BE DEMOLISHED, CONTRACTOR SHALL FIELD VERIFY REP ODUCTION OF THISEDRAWING FOR <br /> DRAIN REUSE ON ANOTHER PROJECT IS NOT <br /> AUTHORIZED AND MAY BE CONTRARY <br /> __�___ NEW BRANCH LINE TO BE INSTALLED SYMBOL SIZE MFR MAKE S.I.N. FINISH STYLE TEMP K-FACTOR --- To �E �aw. <br /> --n-- NEW OUTLET WITH ARM-OVER X <br /> � NEW PIPE "UP" OR "DN" WHERE SPRINKLERS ARE CALLED OUT TO "MATCH EXISTING," THE CONTRACTOR SHALL <br /> C PROVIDE SPRINKLERS MANUFACTURED BY TYCO, WHICH ARE EQUIVALENT TO THE EXISTING <br /> � <br /> LONGITUDINAL SEISMIC BRACING TO REMAIN SPRINKLERS. SUBSTITUTIONS WILL NOT BE PERMITTED. <br /> � VERIFY (12) SALES FLOOR TYPE SPRINKLERS, (4) DRY PENDENT SPRINKLERS, AND (2) OF <br /> LATERAL SEISMIC BRACING EACH OTHER TYPES OF SPRINKLERS ARE PRESENT IN SPRINKLER CABINETS IN SPRINKLER <br /> ROOM. PROVIDE ADDITIONAL SPRINKLERS IN SPRINKLER CABINETS AS REQUIRED. ►-a <br /> � 4-WAY SEISMIC BRACING W <br /> ABBREVIATIONS O O � <br /> ,' HANGER TYP TYPICAL ELL ELBOW O O � W <br /> REF REFER CMU CONCRETE MASONRY UNITS � �p � <br /> ' REDUCER EVAP EVAPORATOR GPM GALLONS PER MINUTE N ,� <br /> AHU AIR HANDLING UNIT PSI POUNDS PER SQUARE INCH � �N � <br /> CONTRACTOR SHALL VERIFY ALL SPRINKLER K-FACTORS, RTU ROOF TOP UNIT MIN MINIMUM � <br /> MAKES, MODELS, AND FIN�SHES. ALL NEW SPRINKLERS RC REDUCING COUPLING MAX MAXIMUM � W <br /> ADDED SHALL MATCH EXISTING SPRINKLERS OF THE BOR BASE OF RISER MECH MECHANICAL <br /> SAME TYPE. FLG FLANGE OR FLANGED HP HORSE POWER � �� U <br /> GRV GROOVED CONT'D CONTINUED � <br /> z <br /> w <br /> O � <br /> O � <br /> � � <br /> O � � <br /> 0 <br /> 0 <br /> O � <br /> a <br /> � � <br /> � <br /> � �-0 1 CONTRACTOR SHALL DROP 1" PIPE TO 12" � <br /> ,� <br /> ;� �, �� �� j, ABOVE PICKUP TOWER TO 4'-0" FLEX PIPE. <br /> ;; ;j; ' r ^ ��� ;; INSTALL PENDENT SPRINKLER INSIDE UNIT. pWq <br /> " '�'' P� P �ti il EXISTING SPRINKLERS AND BRANCHLINES TO <br /> � <br /> iE �;' � <br /> :I ��� ,�� �! REMAIN. REF 5-FP3. Z <br /> ��- -- -:o ; <br /> �' i F�o�� I <br /> w <br /> 'j PICKIJP ��; � <br /> �C H ECK'-I N �-��!' <br /> � �, <br /> �; i ,�`� <br /> �i <br /> � `�-�I <br /> � �-11 CONTRACTOR SHALL REMOVE EXISTING PENDENT ISSUE BLOCK <br /> O CONTRACTOR SHALL ADD NEW PENDENT i j r��; SPRINKLER THAT HAS BEEN PAINTED AND <br /> SPRINKLERS WHERE SHOWN. UTILIZE EXISTING ��': ' � 04/09/18 PERMIT <br /> ;; �; I � _ i �) PROVIDE NEW PENDENT SPRINKLER TO MATCH <br /> �� � i� PIPING WHERE POSSIBLE. COLOR, STYLE AND <br /> i �;- ; , <br /> EXISTING SPRINKLER. <br /> ;; � �� �� -�-- "���� -��--�-�-��-�- - � --�� K-FACTOR SHALL MATCH EXISTING. r�' �j � �i <br /> ' ` i� COORDINATE FINAL LOCATIONS OF NEW ;i �-'I i � <br /> �`�� � k � '��� SPRINKLERS WITH ALL LIGHTS AND OTHER ` !�-'� � TOILET �` <br /> II � ;I �. '� � ; � � ( � � � Ii <br /> � � � � ! ,: i � i CEILING EQUIPMENT. ADDITIONAL SPRINKLERS � ��� � �; <br /> ;j � ��`�'�`' VE TIBULE `'� i ; MAY BE REQUIRED AT NO ADDITIONAL COST TO �� � �- !I 1� <br /> ' OWNER. REF 6-FP3. (TYP OF 3) ' <br /> VESTI B U LE P I CK U P TOWER AU TO CEN TER T01 LET <br /> FIRE PROTECTION PLAN FIRE PROTECTION PLAN FIRE PROTECTION PLAN <br /> 7 3/32" = 1'-0" � 3/32" = 1'-0" � 3/32" = 1'-0" <br /> 30 X 42 SHEET SET <br /> CHECKED BY: JMR <br /> DRAWN BY: JAW <br /> PROTO: 134 WM <br /> PROTO CYCLE: 02/23/18 <br /> DOCUMENT DATE: 04/09/18 <br /> CONTRACTOR FIELD VERIFY <br /> AND SHALL ADD NEW <br /> GUARD ON SPRINKLER. DOCUMENTS WITHOUT <br /> SIGNATURE AND REQUIRED <br /> 11 11.4 12 SEAL OF AOR/EOR ARE <br /> � NOT FOR CONSTRUCTION <br /> „ � ._., ;- , I <br /> - ` � -- �----' I ' ci ; � <br /> ��. ' � j r � r i 7�� r � <br /> _��J I 1.� � L� I'J I�� ,� <br /> ...... i I' I I � I I �+ I <br /> � � � <br /> 1 I <br /> F� I � � ' �_ l�.`JI � <br /> I � I <br /> i ! <br /> I I � c J L J ,��� ! <br /> i I <br /> � <br /> LJ � <br /> �I i i <br /> � �J L J �I � CONTRACTOR SHALL ADD ESCUTCHEON <br /> P ' i �; � ON SPRINKLER. COLOR, AND STYLE <br /> o, LUBE AND TI E �` � 6 SHALL MATCH EXISTING. 7 <br /> � � � <br /> � .,, MOUNTING AR�A LJ i j <br /> rn ! �� TIRE �� ���� ,"�.-� --- -�-� _ ,..____� ---- _ �;----- - `.;,� <br /> CONTRACTOR FIELD VERIFY �-�-�' ���-� , ,; , , <br /> ,n ' - ; RACKS , <br /> � ; AND SHALL ADD NEW ��; ��� ;i ' !' : �) �' <br /> � I i' �� <br /> � F-' �, � �� �) GUARDS ON SPRINKLERS. � �, � � �i �! �' > > �� I; <br /> z TYP OF 5 � � k� � <br /> � � � �� �� � � � � PRODUCE , 'i�� �J �J i l i� J �' �i CONTRACTOR SHALL ADD ESCUTCHEON <br /> I�; � �I ;i GROCERY ON SPRINKLER. COLOR, AND STYLE <br /> Q � LJ LJ�� � <br /> _ _--- -- _-- - - - � � ;��� C00,ER - ` I - ; A Y - �,'I !I FREEZER i i i'� <br /> � i � SHALL MATCH EXISTING. <br /> O - - - ---�-- -- --— - - - --- ---- �` � F � i -' � i, ,, l <br /> � CONTRACTOR SHALL ADD ESCUTCHEON <br /> [��- �� � �'�. , � � �R I � � �,; �,-,---, ON SPRINKLER. COLOR, AND STYLE OY SP <br /> ; � � i � i� COOLER � ii F� � �� �i �� �i S � q <br /> � � � i I,�� \ ; A i�� � _ �? ,�� ,; ( ;i _�� i SHALL MATCH EXISTING. �C s O <br /> U � r� r� , I ( \ '�� —q � I! � t �i,' I I � ----- �I�j �Q'� �� �G' <br /> LyJ � � LJ LJ '�� � � j� � �_�__L-L� � I� 't�� � i�� � �_���� ' ��� i� I� r<<G ��� <br /> � � � z i i � �� � � ' — -- � O <br /> � i � i �� � �k: _ �� `ti � I _ �� � <br /> ; � <br /> ��_m.... . .: _..— __---. .-- ' __..._._ . -- - -- ' � ;i <br /> _ _ _._. __.— i� <br /> � � � � H -�- � <br /> _ ...._ _ , <br /> rJ --- — — - <br /> � L J j i . '��: I I....... .. ��—� �. . j� . <br /> w � -, -------- ' - ---. ' ' CONTRACTOR SHALL ADD NEW INTERMEDIATE LEVEL �I UPC/ I_; i j = <br /> � � I � �� ���' CONTRACTOR SHALL ADD ESCUTCHEON CONTRACTOR SHALL ADD NEW DRY PENDENT 6 I INVOICING: i; 35876 � <br /> i u-� LJ SPRINKLER ABOVE TRASH COMPACTOR CHUTE ' �, <br /> � � I � � i , I ON SPRINKLER. COLOR, AND STYLE SPRINKLER BEHIND EVAPORATOR. UTILIZE �I' � �, @ �I ,c RF�ISTER�O � <br /> ., ,. i ., ,. i OPENING. SUPPLY SPRINKLER FROM OVERHEAD i I � �c G�� <br /> � J � ''" ;�� � , � ��; i i i SHALL MATCH EXISTING. EXISTING PIPING WHERE POSSIBLE. COORDINATE �'� i- � � ss/ E� <br /> , �, ' ( �� - BRANCH LINES. HANG ALL NEW SPRINKLER PIPING ' I ONAL <br /> � , - - <br /> � i J L � � FINAL LOCATION OF NEW SPRINKLER WITH ALL K � ; ; FROM STRUCTURE. REF 4-FP3. �(u i <br /> r <br /> Q LIGHTS AND OTHER CEILING EQUIPMENT. - - - H <br /> � � 1 ; , ��RECEIVING <br /> w ADDITIONAL SPRINKLERS MAY BE REQUIRED AT JAMES ROY SPRADLING <br /> NO ADDITIONAL COST TO OWNER. REF 3-FP3 ENGINEER OF RECORD <br /> N FOR ALL INSTALLATION AND SEALING METHODS. <br /> � <br /> � <br /> � LUBE AND TIRE MOUNTING AREA COOLER /FREEZER RECEIVING UPC INVOICING <br /> � � / <br /> FIRE PROTECTION PLAN FIRE PROTECTION PLAN FIRE PROTECTION PLAN FIRE PROTECTION PLAN ENLARGED <br /> L O <br /> ��' FI R E <br /> w � � 3/32" = 1'-0" � 3/32" = 1'-0" � 3/32" = 1'-0" � 3/32" = 1'-p„ <br /> � �� PROTECTION <br /> � � <br /> � � PLANS <br /> a� <br /> � Q EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br /> � o DRAWINGS AND MAY NOT REFLECT EXACT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br /> i � "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD SPECIFICATIONS IN THEIR RELATED FIELD. THE <br /> � � VERIFY ALL EXISTING CONDITIONS PRIOR TO FAILURE TO ACQUAINT THEMSELF WITH THIS <br /> o � SUBMITTING FINAL BIDS. CONTRACTOR SHALL KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY <br /> �' % CAREFULLY COORDINATE NEW WORK AND DEMOLITION OF PERFORMING THE WORK PROPERLY. NO <br /> o � WITH ALL OTHER DISCIPLINES AND EXISTING ADDITIONAL COMPENSATION SHALL BE ALLOWED SHEET: <br /> a� CONDITIONS. BECAUSE OF CONDITIONS THAT OCCUR DUE F P 2 <br /> Q j TO FAILURE TO FAMILIARIZE WORKERS WITH THIS <br /> � KNOWLEDGE. <br />