Laserfiche WebLink
� <br /> ELECTRICAL SYMBOLS �EGEND GENERAL NOTES <br /> _,__. �Y";��_�- ;�PPLY ON�Y Wh�EfJ U�ED ON DRAWINGS; ES06 <br /> 10.28.16 EN08 ` <br /> � �'�1B����� � DESCRIPTION ', <br /> � O LIGHT FIXTURE 1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND �, <br /> LABOR, FOR A COMPLETE INSTALLATION IN AL� RESPECTS, <br /> (WALL MOUNTED/CEILING MOUN?ED) READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH ' <br /> UGHT FIXTURE NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURER'S � <br /> RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. <br /> , 'JGHT FIXTURE <br /> =MERGENCY LIGHT A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS <br /> THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR <br /> LIGHT FIXTURE WALLS. <br /> NIGHT LIGHT C Y N T E R G Y <br /> B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. <br /> � ENCLOSED COOLER/FREEZER LIGHT <br /> C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE CYNTERGY ENGINEERING, PLLC <br /> 810 S CINCINNATI <br /> OPERATIONS. COORDINATE ALL DISRUPTIONS WITH SECOND FLOOR <br /> TRACK LIGHTING WALMART CONSTRUCTION MANAGER AND STORE MANAGER. TU�SA,OK 74119 <br /> 918.877.6000 <br /> � / � EXIT FIXTURE D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESSES www.cyntergy.com <br /> (WALL MOUNTED/CEILING MOUNTED) BEFORE INSTALLING BOXES. FURNISH AND WSTALL <br /> EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED. <br /> � EMERGENCY FIXTURE <br /> E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED STIPULATION FOR REUSE <br /> PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS <br /> � SWITCH, SINGLE POLE PROPERLY COVERED AND THAT ALL TRIM IS IN GOOD sESORAa�sPEciFicsRTEA,aRr�vERRrT <br /> CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. (w), wa, coNrEMPORaNEous�Y wiTH <br /> ITS ISSUE DATE ON 04/09/18, AND IT <br /> �3 SWITCH, 3-WAY 2. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: is Nor suira,e�E FOR usE oN a <br /> DIFFERENT PROJECT SITE OR AT A <br /> A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE �arER TirnE. usE oF THis oRa,wiNc <br /> �4 SWITCH, 4—WAY ANOTHER PROJECT REQUIRES THE <br /> STOPPING. N xAMP� oN <br /> B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. sERvicEs oF PROPER�Y ucENSE� <br /> ARCHITECTS AND ENGWEERS. <br /> SK SWITCH, KEYED <br /> �� FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM REPRooucTioN oF THis oRnwiNc FOR <br /> REUSE ON ANOTHER PROJECT IS NOT <br /> SEALANT. AUTNORIZED AND MAY" BE CONTRARY <br /> �� SWITCH, DIMMER D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR To rHE �aw. <br /> SEA�ING REQUIREMENTS AT ALL EXTERIOR MOUNTED <br /> �VS SWITCH, VARIBLE SPEED DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY <br /> PENETRATIONS. <br /> SWITCH, MANUAL MOTOR 3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR <br /> WM (SIZE PER NEC) IN PVC TYPE CONDUIT, POWER CIRCUITS, <br /> ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. <br /> �OS SWITCH, OCCUPANCY SENSOR <br /> CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 <br /> VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT <br /> �OS SWITCH, BI-LEVEL OCCUPANCY SENSOR • <br /> 4. WIRING DEVICES: DEVICE MOUNTING NEIGHTS ARE FROM W <br /> �S/ a CEILWG OCCUPANCY SENSOR AND ASSOCIATED RELAY FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED O O <br /> OTHERWISE ON PLANS. COORDINATE THE STANDARD Q <br /> O <br /> MOUNTING HEIGHTS WITH MASONRY: O C7 � <br /> � RECEPTACLE, DUPLEX A. SWITCHES +44" O O � W <br /> RECEPTACLE, DUPLEX, B. RECEPTACLES +20" —�� � � <br /> � C. VOICE/DATA +20" �� � <br /> MOUNTED HORIZONTALLY � N <br /> 5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT � � � <br /> � RECEPTACLE, DOUBLE DUPLEX �N CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING � �� W <br /> DIAGRAMS. �� � O� W <br /> Q RECEPTACLE, DUPLEX ISOLATED GROUND 6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE ��U) � � <br /> PANELBOARD IDENTIFICATION SCHEDULES FOR PANE�BOARDS u <br /> � RECEPTACLE, DOUBLE DUPLEX, AFFECTED BY REMODEL. 0 <br /> ISOLATED GROUND Z <br /> RECEPTACLE, SIMPLEX TWIST LOCK, 7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN <br /> � EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHA�� W <br /> "J !5-15R, UNO MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT 0 � <br /> �, ;ECEPTACLE, SIMPLEX TWIST LOCK, PROTECTIVE DEVICES. O � <br /> �T% ISOLATED GROUND, L5-15R, UNO 8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG � Cn � <br /> � RECEPTACLE, DUPLEX TWIST LOCK, UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A o <br /> L5-15R, UNO BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 I <br /> RECEPTACLE, DUPLEX TWIST LOCK, AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION � <br /> � ISOLATED GROUND, L5-'SR, UNO (15-FT MAXIMUM). � <br /> {� RECEPTACLE, SPECIAL 9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND � <br /> DERATE CURRENT CARRYtNG CONDUCTORS PER NEC. w <br /> � <br /> � RECEPTACLE, SIMPLEX 10. PROVIDE UL USTED HANDLE TIES ON ALL MULTIWIRE BRANCH � <br /> CIRCUITS PER NEC REQUIREMENTS. � <br /> � <br /> � RECEPTACLE, PLUG-MOLD 11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE � <br /> O JUNCTION BOX SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. � <br /> (WALL MOUNTED/CEILING MOUNTED) UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR <br /> SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. <br /> O JUNCTION BOX, ALARM SYSTEM �2. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE ISSUE BLOCK <br /> A (WALL MOUNTED/CEILING MOUNTED) <br /> ALARM JUNCTION BOX, SURFACE MOUNTED UNLESS NOTED OTHERWISE. REFER TO <br /> O FOR REMOTE TEST/RESET SEALINGCREQUIREDM�ENTSENTS FOR CONDUIT INSTA�LATION AND 04/09/18 PERMIT <br /> (WALL MOUNTED/CEILING MOUNTED) <br /> EQUIPMENT CONNECTION POINT 13. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM <br /> 0 AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE <br /> (PROVIDED WITH EQUIPMENT) INSTALLED UNDER SLAB. ALL OTHER FEEDER AND BRANCH <br /> ❑, NON-FUSED DISCONNECT CIRCUITS SHALL BE INSTALLED OVERHEAD. PROVIDE EXTERtOR <br /> COATED GRC BENDS ON ALL CONDUIT RUNS THAT HAVE 45 <br /> DEGREE BENDS OR GREATER. REF SPECIFICATIONS. <br /> !� FUSED DISCONNECT 14. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS <br /> =��-_-=_ - _ _ ' CIRCUIT, CONCEALED !N WA�LS OR AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY <br /> CEILING, E INDICATES EXISTING LOCAL CODES FOR SEISMIC DESIGN CATEGORY 'D'. <br /> �c _;��°;.` WIRING <br /> 15. EXISTING ELECTRICAL AND ALARM: <br /> CIRCUIT, CONCEALED IN FLOOR SLAB, A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br /> -'� µ � r INDICATES EXISTING WIRING EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING <br /> —�;�„� �IRCUIT, EXPOSED, EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT <br /> = INDICATES EXISTING WIRING SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TC <br /> REWORK CIRCUITRY, AS REQUIRED, TO MAINTAW EXISTING <br /> = =LUSH MOUNTED PANELBOARD OPERATION. <br /> B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT <br /> — �URFACE MOUNTED PANELBOARD EXISTWG UNDERGROUND SERVICES (ELECTRICAL, <br /> TELEPHONE, PARKING LOT LIGHTING CIRCUITRY, ETC.) <br /> - - - VOICE/DATA, PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO <br /> � . d = DATA ONLY, v = VOICE ONLY REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES <br /> TO MAINTAIN THEIR EXISTING OPERATION. 30 X 42 SH�ET �ET <br /> Q �OW VOLTAGE CABLE BOX FOR OTHER <br /> C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES <br /> DURING DEMOLITION AND CONSTRUCTION. PROTECT A�ARM <br /> � VOICE/DATA, FLUSH FLOOR CABLE WHIPS OUT OF POWER POLE SHALL BE WSTALLED IN AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO CHECKED BY: ESK <br /> A NEAT AND WORKMAN-LIKE MANNER. ROUTE CABLE WHIPS THAT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES. <br /> �/ MOTOR TO TERMINATIONS ALONG UNISTRUT OR STRUCTURE AND DRAWN BY: JAK <br /> /v SUPPORT EVERY 12" TO 24". EXCESS CABLE SHALL BE D. DISPOSE OF ALL REMOVED MATERIALS, UN�ESS OTHERWISE <br /> TIGHTLY COILED AND ATTACHED TO UNISTRUT OR JOIST. <br /> NOTED. PROTO: 134 WM <br /> ;] TELEPOWER POLE <br /> 16. EXISTING ELECTRICAL DEMOLITION: <br /> • PUSH BUTTON �;' NO CONNECTION OF ANY KIND SHALL BE MADE <br /> A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL PROTO CYCLE: 02/23/18 <br /> � � �'�� ,� ' TO JOIST WEB MEMBERS, JOIST BRIDGING, OR EQUIPMENT CONDUIT, AND CONDUCTORS AS INDICATED ON DOCUMENT DATE: 04�09�18 <br /> R00� DECK. MAINTAIN MINIMUM 6" CLEARANCE THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. <br /> � :�� t - REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, <br /> BUZZER , a FROM TOP OF POWER POLE TO ROOF DECK. so' RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH <br /> OS SMOKE DETECTOR � `` ° �>`� WILL NOT BE REUSED. <br /> DOCUMENTS WITHOUT <br /> � .- � �� SIGNATURE AND REQUIRED <br /> , ,�^ REF� MANUFACTURER'S "GEI�JERA� � ; , � B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, <br /> � ENERGY MANAGEMENT �� FITTINGS SPECIFICATIONS" FOR ;': CONDUCTORS AND RELATED DEVICES SERVING SALES AREA SEAL OF AOR/EOR ARE <br /> � S TEMPERATURE SENSOR ��� r� � DESIGN BOLT TORQUE. � y i 1',� � GONDOLAS BEING RELOCATED OR REMOVED. EXISTING NOT FOR CONSTRUCTION <br /> � �` , �" � ,° e=� ,� CONDUIT AND CONDUCTORS MAY BE REUSED �OR NEW <br /> � THERMOSTAT ��ii ' x� ' � POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET <br /> ' ' ` � 4 REQUIREMENTS INDICATED ON PLANS AND ALL U.L. <br /> � „ � � � i � <br /> TC TIME CLOCK �, � ;�} �EXTEND POWER POLE 3" : 3�\ , RATINGS. REMOVE ALL UNUSED CONDUIT AND <br /> ~�� �� � __- - - --- - � MIN ABOVE CL OF UNISTRUT �E�� �� ' CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER <br /> � _- �. : I <br /> -- Ff� �.; . <br /> �EASIB�E AND RELABE� DEMOLISHED CIRCUITS AS "SPARE". <br /> ABBREVIATIONS ' ° � PROVIDE HANDLE DEV"ICE TO LOCK "SPARE" CIRCUIT <br /> �. b, c LOWER CASE LETTERS INDICATE HD HAND DRYER � 12" PVC SLEEVE�* � <br /> BREAKER IN THE "OFF" POSITION. <br /> SWITCHING CONFIGURATION IG ISOLATED GROUND <br /> =_� ABOVE FINISH COUNTER IRC INTER-REGISTER =� C. CONDUIT AND WIRING TO BE ABANDONED IN CEILWG <br /> =_� ABOVE FINISH FLOOR COMMUNICATION SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH <br /> =_� ABOVE FINISH GRADE ISP IN-STORE PROCESSOR �INSTALL CEILING FLAiJGE -PROVIDE UNISTRUT PER STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE <br /> CONDUIT LCU LIGHTING CONTROL UNIT — 3" X 3" 1/4" ANGLE BETWEEN z ,-' 'i . SPECIFICATIONS. LENGTH AS <br /> -T � BAR JOISTS AT PANEL POINTS. _ , � PROVIDED WITH POLE FOR FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE. <br /> _ � � CIRCUIT K KEY OPERATED �' '�� STORES WITH LAY-IN CEILING � �- ' ��� REQUIRED TO SPAN JOISTS. <br /> - CEIUNG/CIRCULATION FAN N NEUTRAL '" CONDUIT TO BE ABANDONED IN WALLS OR FLOORS SHAL� <br /> - _ i J-BOX SECURED TO SECURE TO BOTTOM CHORD BE REMOVED BACK TO FINISHED SURFACE AND CAPPED <br /> - DATA NTS NOT TO SCALE �� 2-1 2 UNISTRUT <br /> _ _� ELECTRICAL CONTRACTOR P WITH PILOT LIGHT � BAR JOIST OR STRAP FIRMLY CLAMPED ;� CONTRACTOR SHALL ATTACH POWER OF BAR JOIST. INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT. <br /> -- EXHAUST FAN RH RADIANT HEATER � BRIDGING. D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE <br /> _ <br /> TO CONDUIT POLE TO CHECKOUT STAND PER <br /> - _� EXPLOSION PROOF RC REFRIGERATION <br /> ' MANUFACTURER RECOMMENDATIONS ABANDONED OR REMOVED SHALL REMAIN IN RESPECTIVE <br /> _ <br /> - _-� EXISTING TO REMAIN CONTRACTOR � '� PROVIDE 1/4" BOLT PANELBOARD FOR FUTURE USE, UNLESS NOTED OTHERWISE <br /> - =,"�C ELECTRIC WATER COOLER SC SECURITY CAMERA <br /> ' , AND 1-1/4" FENDER ON DRAWINGS. PROVIDE HANDLE DEVICE TO LOCK "SPARE" <br /> - _�T FUTURE SF SUPPLY FAN � ' UNISTRUT� � WASHER TYP CIRCUIT BREAKER IN THE "OFF" POSITION. <br /> � �� GROUND TR TAMPER RESISTANT � �� � � I '-" ��ASH AND SHOCK HAZARD. g, KESTF <br /> �-�P GROUND FAULT EQUIPMENT TYP TYPICAL � �� � t E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO �G Rs <br /> PROTECTION wH WATER HEaTER � : APPROPRIATE PERSONAL PROTECTIVE <br /> r <br /> � �PROVIDE UNISTRUT SELECTIVE SITE DEMOLITION SPECI�ICATION FOR �,Q` �OF WASy�N ��, <br /> -= GROUND FAULT CIRCUIT WP WEATHERPROOF %, /i k � �` P1026 ANG�E EQU��P�,1Ei�,l ' �PPE� REQUIRED. DISPOSAL 0� LIGHT FIXTURE. ��' co <br /> � � FITTING OR EQUA� � <br /> - INTERRUPTER WR WEATHER RESISTANT "KELLEMS" STRAIN �/ � POWER POLE Jrj�' � �. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF � <br /> �' UNIT HEATER � ' �- � � _ � � � <br /> GABLE FAN UH � RELIE� CONTAINMENT ; � , ; - ---- � � - � NOTE�: WORK SHALL BE SECURED TO P�REVENT FALLING, - � <br /> �����, uN�Ess NOT�� 2—�/2`;� INSET � � � <br /> O T H E R W I S E GRIP �\ P V C J/ � ' '� LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE �,p R48048 �� <br /> � CONDUIT •� `� A. ALL SWITCHBOARDS AND PANELBOARDS SHAL� FUTURE. �,c� F� <br /> � >- � ;" ' HAVE A COMMERC�ALLY PRODUCED PERMANENT �ABEL F <br /> � SO CORD AS SPECIFIED INSET: CLAMP A 12" LENGTH ,, �,'�. ' � ;� APPLIED, SIMILAR TO THE ABOVE, TO WARN OF 17. ETHERNET CABLE: <br /> FOR EQUIPMENT. OF PVC CONDUIT AND RUN THE � PROVIDE 1-1/4" �_ POTENTIAL ARC F�ASH HAZARDS, IN ACCORDANCE A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON t�r.•� �i�' <br /> E�� BOTTOM <br /> , , FENDER WASHER, LOCK � INSET WITH NEC 110.16 AND NFPA 70E. <br /> POWER POLE THROUGH ITS CENTER ' CHORD OF PLANS. PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES <br /> CONNECTOR AS—�, „ �:r,� _ WASHER AND NUT, TYP-� - ����� BAR JOIST AND�OR ORDINANCES. ERIC KESTERSON, P.E. <br /> SPECIFIED FOR - B. LABELING MAY BE COMP�ETED BY EQUIPMENT �NciNEER oF REcoRo <br /> EQUIPMENT. INSET: MOUNT UNISTRUT ABOVE BOTTOM CHORD OF BAR MANUFACTURER, EQUIPMENT VENDOR/SUPPLIER, OR B. ETHERNET CABLE IS FURNISHED BY OTHERS. <br /> FINISHED JOISTS USING 1�4" BOLTS, WITH FENDER WASHERS AND THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER <br /> = S U S P E N D E D P 0 WE R D R 0 P F�ooR �OCK WASHERS BETWEEN BO�T HEAD AND JOIST FLANGE THAT ALL SWITCHBOARDS AND PANELBOARDS ARE POLES. <br /> PROPERLY LABE�ED IN THE FIELD. <br /> _ D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS ELECTRICAL <br /> — DIRECTED BY WALMA.RT CONSTRUCTION MANAGER. <br /> L DETAI � OPEN TO STRU CTU RE POWER PO �E CON N ECTI ON 1 ARC ��ASH DETAI L DETAILS <br /> - � NTS 07.26.13 !i",EP��= � NTS 07.31.12 EP42 I NTS 0217.06 v^,�E=' �1' AN � <br /> - SCHEDULES <br /> c <br /> EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br /> � DRAWINGS AND MAY NOT REFLECT EXACT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br /> "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIE�D SPECIFICATIONS IN THEIR RELATED FIELD. THE <br /> = VERIFY ALL EXISTING CONDITIONS PRIOR TO FAILURE TO ACQUAINT THEMSELF WITH THIS <br /> SUBMITTING �INAL BIDS. CONTRACTOR SHALL KNOWLEDGE DOES NOT RE�IEVE THE RESPONSIBILITY <br /> - CAREFULLY COORDINATE NEW WORK AND DEMOLITION OF PERFORMING THE WORK PROPERLY. NO <br /> WITH ALL OTHER DISCIPLINES AND EXISTING ADDITIONAL COMPENSATION SHALL BE ALLOWED SHEET: <br /> ` CONDITIONS. BECAUSE OF CONDITIONS THAT OCCUR DUE � � <br /> - TO FAILURE TO FAMILIARIZE WORKERS WITH THIS <br /> < <br /> KNOWLEDGE. <br />