<br /> ELECTRICAL SYMBOLS �EGEND GENERAL NOTES
<br /> _,__. �Y";��_�- ;�PPLY ON�Y Wh�EfJ U�ED ON DRAWINGS; ES06
<br /> 10.28.16 EN08 `
<br /> � �'�1B����� � DESCRIPTION ',
<br /> � O LIGHT FIXTURE 1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND �,
<br /> LABOR, FOR A COMPLETE INSTALLATION IN AL� RESPECTS,
<br /> (WALL MOUNTED/CEILING MOUN?ED) READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH '
<br /> UGHT FIXTURE NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURER'S �
<br /> RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS.
<br /> , 'JGHT FIXTURE
<br /> =MERGENCY LIGHT A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS
<br /> THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR
<br /> LIGHT FIXTURE WALLS.
<br /> NIGHT LIGHT C Y N T E R G Y
<br /> B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE.
<br /> � ENCLOSED COOLER/FREEZER LIGHT
<br /> C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE CYNTERGY ENGINEERING, PLLC
<br /> 810 S CINCINNATI
<br /> OPERATIONS. COORDINATE ALL DISRUPTIONS WITH SECOND FLOOR
<br /> TRACK LIGHTING WALMART CONSTRUCTION MANAGER AND STORE MANAGER. TU�SA,OK 74119
<br /> 918.877.6000
<br /> � / � EXIT FIXTURE D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESSES www.cyntergy.com
<br /> (WALL MOUNTED/CEILING MOUNTED) BEFORE INSTALLING BOXES. FURNISH AND WSTALL
<br /> EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED.
<br /> � EMERGENCY FIXTURE
<br /> E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED STIPULATION FOR REUSE
<br /> PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS
<br /> � SWITCH, SINGLE POLE PROPERLY COVERED AND THAT ALL TRIM IS IN GOOD sESORAa�sPEciFicsRTEA,aRr�vERRrT
<br /> CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. (w), wa, coNrEMPORaNEous�Y wiTH
<br /> ITS ISSUE DATE ON 04/09/18, AND IT
<br /> �3 SWITCH, 3-WAY 2. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: is Nor suira,e�E FOR usE oN a
<br /> DIFFERENT PROJECT SITE OR AT A
<br /> A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE �arER TirnE. usE oF THis oRa,wiNc
<br /> �4 SWITCH, 4—WAY ANOTHER PROJECT REQUIRES THE
<br /> STOPPING. N xAMP� oN
<br /> B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. sERvicEs oF PROPER�Y ucENSE�
<br /> ARCHITECTS AND ENGWEERS.
<br /> SK SWITCH, KEYED
<br /> �� FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM REPRooucTioN oF THis oRnwiNc FOR
<br /> REUSE ON ANOTHER PROJECT IS NOT
<br /> SEALANT. AUTNORIZED AND MAY" BE CONTRARY
<br /> �� SWITCH, DIMMER D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR To rHE �aw.
<br /> SEA�ING REQUIREMENTS AT ALL EXTERIOR MOUNTED
<br /> �VS SWITCH, VARIBLE SPEED DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY
<br /> PENETRATIONS.
<br /> SWITCH, MANUAL MOTOR 3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR
<br /> WM (SIZE PER NEC) IN PVC TYPE CONDUIT, POWER CIRCUITS,
<br /> ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS.
<br /> �OS SWITCH, OCCUPANCY SENSOR
<br /> CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600
<br /> VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT
<br /> �OS SWITCH, BI-LEVEL OCCUPANCY SENSOR •
<br /> 4. WIRING DEVICES: DEVICE MOUNTING NEIGHTS ARE FROM W
<br /> �S/ a CEILWG OCCUPANCY SENSOR AND ASSOCIATED RELAY FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED O O
<br /> OTHERWISE ON PLANS. COORDINATE THE STANDARD Q
<br /> O
<br /> MOUNTING HEIGHTS WITH MASONRY: O C7 �
<br /> � RECEPTACLE, DUPLEX A. SWITCHES +44" O O � W
<br /> RECEPTACLE, DUPLEX, B. RECEPTACLES +20" —�� � �
<br /> � C. VOICE/DATA +20" �� �
<br /> MOUNTED HORIZONTALLY � N
<br /> 5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT � � �
<br /> � RECEPTACLE, DOUBLE DUPLEX �N CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING � �� W
<br /> DIAGRAMS. �� � O� W
<br /> Q RECEPTACLE, DUPLEX ISOLATED GROUND 6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE ��U) � �
<br /> PANELBOARD IDENTIFICATION SCHEDULES FOR PANE�BOARDS u
<br /> � RECEPTACLE, DOUBLE DUPLEX, AFFECTED BY REMODEL. 0
<br /> ISOLATED GROUND Z
<br /> RECEPTACLE, SIMPLEX TWIST LOCK, 7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN
<br /> � EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHA�� W
<br /> "J !5-15R, UNO MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT 0 �
<br /> �, ;ECEPTACLE, SIMPLEX TWIST LOCK, PROTECTIVE DEVICES. O �
<br /> �T% ISOLATED GROUND, L5-15R, UNO 8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG � Cn �
<br /> � RECEPTACLE, DUPLEX TWIST LOCK, UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A o
<br /> L5-15R, UNO BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 I
<br /> RECEPTACLE, DUPLEX TWIST LOCK, AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION �
<br /> � ISOLATED GROUND, L5-'SR, UNO (15-FT MAXIMUM). �
<br /> {� RECEPTACLE, SPECIAL 9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND �
<br /> DERATE CURRENT CARRYtNG CONDUCTORS PER NEC. w
<br /> �
<br /> � RECEPTACLE, SIMPLEX 10. PROVIDE UL USTED HANDLE TIES ON ALL MULTIWIRE BRANCH �
<br /> CIRCUITS PER NEC REQUIREMENTS. �
<br /> �
<br /> � RECEPTACLE, PLUG-MOLD 11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE �
<br /> O JUNCTION BOX SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. �
<br /> (WALL MOUNTED/CEILING MOUNTED) UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR
<br /> SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS.
<br /> O JUNCTION BOX, ALARM SYSTEM �2. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE ISSUE BLOCK
<br /> A (WALL MOUNTED/CEILING MOUNTED)
<br /> ALARM JUNCTION BOX, SURFACE MOUNTED UNLESS NOTED OTHERWISE. REFER TO
<br /> O FOR REMOTE TEST/RESET SEALINGCREQUIREDM�ENTSENTS FOR CONDUIT INSTA�LATION AND 04/09/18 PERMIT
<br /> (WALL MOUNTED/CEILING MOUNTED)
<br /> EQUIPMENT CONNECTION POINT 13. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM
<br /> 0 AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE
<br /> (PROVIDED WITH EQUIPMENT) INSTALLED UNDER SLAB. ALL OTHER FEEDER AND BRANCH
<br /> ❑, NON-FUSED DISCONNECT CIRCUITS SHALL BE INSTALLED OVERHEAD. PROVIDE EXTERtOR
<br /> COATED GRC BENDS ON ALL CONDUIT RUNS THAT HAVE 45
<br /> DEGREE BENDS OR GREATER. REF SPECIFICATIONS.
<br /> !� FUSED DISCONNECT 14. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS
<br /> =��-_-=_ - _ _ ' CIRCUIT, CONCEALED !N WA�LS OR AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY
<br /> CEILING, E INDICATES EXISTING LOCAL CODES FOR SEISMIC DESIGN CATEGORY 'D'.
<br /> �c _;��°;.` WIRING
<br /> 15. EXISTING ELECTRICAL AND ALARM:
<br /> CIRCUIT, CONCEALED IN FLOOR SLAB, A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS
<br /> -'� µ � r INDICATES EXISTING WIRING EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING
<br /> —�;�„� �IRCUIT, EXPOSED, EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT
<br /> = INDICATES EXISTING WIRING SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TC
<br /> REWORK CIRCUITRY, AS REQUIRED, TO MAINTAW EXISTING
<br /> = =LUSH MOUNTED PANELBOARD OPERATION.
<br /> B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT
<br /> — �URFACE MOUNTED PANELBOARD EXISTWG UNDERGROUND SERVICES (ELECTRICAL,
<br /> TELEPHONE, PARKING LOT LIGHTING CIRCUITRY, ETC.)
<br /> - - - VOICE/DATA, PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO
<br /> � . d = DATA ONLY, v = VOICE ONLY REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES
<br /> TO MAINTAIN THEIR EXISTING OPERATION. 30 X 42 SH�ET �ET
<br /> Q �OW VOLTAGE CABLE BOX FOR OTHER
<br /> C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES
<br /> DURING DEMOLITION AND CONSTRUCTION. PROTECT A�ARM
<br /> � VOICE/DATA, FLUSH FLOOR CABLE WHIPS OUT OF POWER POLE SHALL BE WSTALLED IN AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO CHECKED BY: ESK
<br /> A NEAT AND WORKMAN-LIKE MANNER. ROUTE CABLE WHIPS THAT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES.
<br /> �/ MOTOR TO TERMINATIONS ALONG UNISTRUT OR STRUCTURE AND DRAWN BY: JAK
<br /> /v SUPPORT EVERY 12" TO 24". EXCESS CABLE SHALL BE D. DISPOSE OF ALL REMOVED MATERIALS, UN�ESS OTHERWISE
<br /> TIGHTLY COILED AND ATTACHED TO UNISTRUT OR JOIST.
<br /> NOTED. PROTO: 134 WM
<br /> ;] TELEPOWER POLE
<br /> 16. EXISTING ELECTRICAL DEMOLITION:
<br /> • PUSH BUTTON �;' NO CONNECTION OF ANY KIND SHALL BE MADE
<br /> A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL PROTO CYCLE: 02/23/18
<br /> � � �'�� ,� ' TO JOIST WEB MEMBERS, JOIST BRIDGING, OR EQUIPMENT CONDUIT, AND CONDUCTORS AS INDICATED ON DOCUMENT DATE: 04�09�18
<br /> R00� DECK. MAINTAIN MINIMUM 6" CLEARANCE THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION.
<br /> � :�� t - REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES,
<br /> BUZZER , a FROM TOP OF POWER POLE TO ROOF DECK. so' RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH
<br /> OS SMOKE DETECTOR � `` ° �>`� WILL NOT BE REUSED.
<br /> DOCUMENTS WITHOUT
<br /> � .- � �� SIGNATURE AND REQUIRED
<br /> , ,�^ REF� MANUFACTURER'S "GEI�JERA� � ; , � B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT,
<br /> � ENERGY MANAGEMENT �� FITTINGS SPECIFICATIONS" FOR ;': CONDUCTORS AND RELATED DEVICES SERVING SALES AREA SEAL OF AOR/EOR ARE
<br /> � S TEMPERATURE SENSOR ��� r� � DESIGN BOLT TORQUE. � y i 1',� � GONDOLAS BEING RELOCATED OR REMOVED. EXISTING NOT FOR CONSTRUCTION
<br /> � �` , �" � ,° e=� ,� CONDUIT AND CONDUCTORS MAY BE REUSED �OR NEW
<br /> � THERMOSTAT ��ii ' x� ' � POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET
<br /> ' ' ` � 4 REQUIREMENTS INDICATED ON PLANS AND ALL U.L.
<br /> � „ � � � i �
<br /> TC TIME CLOCK �, � ;�} �EXTEND POWER POLE 3" : 3�\ , RATINGS. REMOVE ALL UNUSED CONDUIT AND
<br /> ~�� �� � __- - - --- - � MIN ABOVE CL OF UNISTRUT �E�� �� ' CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER
<br /> � _- �. : I
<br /> -- Ff� �.; .
<br /> �EASIB�E AND RELABE� DEMOLISHED CIRCUITS AS "SPARE".
<br /> ABBREVIATIONS ' ° � PROVIDE HANDLE DEV"ICE TO LOCK "SPARE" CIRCUIT
<br /> �. b, c LOWER CASE LETTERS INDICATE HD HAND DRYER � 12" PVC SLEEVE�* �
<br /> BREAKER IN THE "OFF" POSITION.
<br /> SWITCHING CONFIGURATION IG ISOLATED GROUND
<br /> =_� ABOVE FINISH COUNTER IRC INTER-REGISTER =� C. CONDUIT AND WIRING TO BE ABANDONED IN CEILWG
<br /> =_� ABOVE FINISH FLOOR COMMUNICATION SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH
<br /> =_� ABOVE FINISH GRADE ISP IN-STORE PROCESSOR �INSTALL CEILING FLAiJGE -PROVIDE UNISTRUT PER STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE
<br /> CONDUIT LCU LIGHTING CONTROL UNIT — 3" X 3" 1/4" ANGLE BETWEEN z ,-' 'i . SPECIFICATIONS. LENGTH AS
<br /> -T � BAR JOISTS AT PANEL POINTS. _ , � PROVIDED WITH POLE FOR FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE.
<br /> _ � � CIRCUIT K KEY OPERATED �' '�� STORES WITH LAY-IN CEILING � �- ' ��� REQUIRED TO SPAN JOISTS.
<br /> - CEIUNG/CIRCULATION FAN N NEUTRAL '" CONDUIT TO BE ABANDONED IN WALLS OR FLOORS SHAL�
<br /> - _ i J-BOX SECURED TO SECURE TO BOTTOM CHORD BE REMOVED BACK TO FINISHED SURFACE AND CAPPED
<br /> - DATA NTS NOT TO SCALE �� 2-1 2 UNISTRUT
<br /> _ _� ELECTRICAL CONTRACTOR P WITH PILOT LIGHT � BAR JOIST OR STRAP FIRMLY CLAMPED ;� CONTRACTOR SHALL ATTACH POWER OF BAR JOIST. INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT.
<br /> -- EXHAUST FAN RH RADIANT HEATER � BRIDGING. D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE
<br /> _
<br /> TO CONDUIT POLE TO CHECKOUT STAND PER
<br /> - _� EXPLOSION PROOF RC REFRIGERATION
<br /> ' MANUFACTURER RECOMMENDATIONS ABANDONED OR REMOVED SHALL REMAIN IN RESPECTIVE
<br /> _
<br /> - _-� EXISTING TO REMAIN CONTRACTOR � '� PROVIDE 1/4" BOLT PANELBOARD FOR FUTURE USE, UNLESS NOTED OTHERWISE
<br /> - =,"�C ELECTRIC WATER COOLER SC SECURITY CAMERA
<br /> ' , AND 1-1/4" FENDER ON DRAWINGS. PROVIDE HANDLE DEVICE TO LOCK "SPARE"
<br /> - _�T FUTURE SF SUPPLY FAN � ' UNISTRUT� � WASHER TYP CIRCUIT BREAKER IN THE "OFF" POSITION.
<br /> � �� GROUND TR TAMPER RESISTANT � �� � � I '-" ��ASH AND SHOCK HAZARD. g, KESTF
<br /> �-�P GROUND FAULT EQUIPMENT TYP TYPICAL � �� � t E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO �G Rs
<br /> PROTECTION wH WATER HEaTER � : APPROPRIATE PERSONAL PROTECTIVE
<br /> r
<br /> � �PROVIDE UNISTRUT SELECTIVE SITE DEMOLITION SPECI�ICATION FOR �,Q` �OF WASy�N ��,
<br /> -= GROUND FAULT CIRCUIT WP WEATHERPROOF %, /i k � �` P1026 ANG�E EQU��P�,1Ei�,l ' �PPE� REQUIRED. DISPOSAL 0� LIGHT FIXTURE. ��' co
<br /> � � FITTING OR EQUA� �
<br /> - INTERRUPTER WR WEATHER RESISTANT "KELLEMS" STRAIN �/ � POWER POLE Jrj�' � �. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF �
<br /> �' UNIT HEATER � ' �- � � _ � � �
<br /> GABLE FAN UH � RELIE� CONTAINMENT ; � , ; - ---- � � - � NOTE�: WORK SHALL BE SECURED TO P�REVENT FALLING, - �
<br /> �����, uN�Ess NOT�� 2—�/2`;� INSET � � �
<br /> O T H E R W I S E GRIP �\ P V C J/ � ' '� LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE �,p R48048 ��
<br /> � CONDUIT •� `� A. ALL SWITCHBOARDS AND PANELBOARDS SHAL� FUTURE. �,c� F�
<br /> � >- � ;" ' HAVE A COMMERC�ALLY PRODUCED PERMANENT �ABEL F
<br /> � SO CORD AS SPECIFIED INSET: CLAMP A 12" LENGTH ,, �,'�. ' � ;� APPLIED, SIMILAR TO THE ABOVE, TO WARN OF 17. ETHERNET CABLE:
<br /> FOR EQUIPMENT. OF PVC CONDUIT AND RUN THE � PROVIDE 1-1/4" �_ POTENTIAL ARC F�ASH HAZARDS, IN ACCORDANCE A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON t�r.•� �i�'
<br /> E�� BOTTOM
<br /> , , FENDER WASHER, LOCK � INSET WITH NEC 110.16 AND NFPA 70E.
<br /> POWER POLE THROUGH ITS CENTER ' CHORD OF PLANS. PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES
<br /> CONNECTOR AS—�, „ �:r,� _ WASHER AND NUT, TYP-� - ����� BAR JOIST AND�OR ORDINANCES. ERIC KESTERSON, P.E.
<br /> SPECIFIED FOR - B. LABELING MAY BE COMP�ETED BY EQUIPMENT �NciNEER oF REcoRo
<br /> EQUIPMENT. INSET: MOUNT UNISTRUT ABOVE BOTTOM CHORD OF BAR MANUFACTURER, EQUIPMENT VENDOR/SUPPLIER, OR B. ETHERNET CABLE IS FURNISHED BY OTHERS.
<br /> FINISHED JOISTS USING 1�4" BOLTS, WITH FENDER WASHERS AND THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN POWER
<br /> = S U S P E N D E D P 0 WE R D R 0 P F�ooR �OCK WASHERS BETWEEN BO�T HEAD AND JOIST FLANGE THAT ALL SWITCHBOARDS AND PANELBOARDS ARE POLES.
<br /> PROPERLY LABE�ED IN THE FIELD.
<br /> _ D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS ELECTRICAL
<br /> — DIRECTED BY WALMA.RT CONSTRUCTION MANAGER.
<br /> L DETAI � OPEN TO STRU CTU RE POWER PO �E CON N ECTI ON 1 ARC ��ASH DETAI L DETAILS
<br /> - � NTS 07.26.13 !i",EP��= � NTS 07.31.12 EP42 I NTS 0217.06 v^,�E=' �1' AN �
<br /> - SCHEDULES
<br /> c
<br /> EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING
<br /> � DRAWINGS AND MAY NOT REFLECT EXACT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND
<br /> "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIE�D SPECIFICATIONS IN THEIR RELATED FIELD. THE
<br /> = VERIFY ALL EXISTING CONDITIONS PRIOR TO FAILURE TO ACQUAINT THEMSELF WITH THIS
<br /> SUBMITTING �INAL BIDS. CONTRACTOR SHALL KNOWLEDGE DOES NOT RE�IEVE THE RESPONSIBILITY
<br /> - CAREFULLY COORDINATE NEW WORK AND DEMOLITION OF PERFORMING THE WORK PROPERLY. NO
<br /> WITH ALL OTHER DISCIPLINES AND EXISTING ADDITIONAL COMPENSATION SHALL BE ALLOWED SHEET:
<br /> ` CONDITIONS. BECAUSE OF CONDITIONS THAT OCCUR DUE � �
<br /> - TO FAILURE TO FAMILIARIZE WORKERS WITH THIS
<br /> <
<br /> KNOWLEDGE.
<br />
|