Laserfiche WebLink
.. . .il` If_.. . . . . <br /> N <br /> Et <br /> .'�$ <br /> � . <br /> � ,i. . <br /> �� <br /> � <br /> DEMOLITION GENERAL NOTES KeyPlan: . <br /> 1.THESE DEMOLITION DRAWiNGS HAVE BEEN COMPILED FROM THE BEST AVAILABLE <br /> INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF THE WORK.IT WILL BE <br /> ASSUMED THAT THE CONTRACTOR HAS INSPECTED THE SITE PRIOR TO BIDDING AND <br /> VERIFIED THE INFORMATION HEREIN SUPPLIED. <br /> 2.INTENT IS TO REMOVE EVERYTHING NECESSARY TO ALLOW NEW CONSTRUCTION TO BE 0 a' s• �s' "� �< <br /> ACCOMPLISHED.SEE DRAWINGS SHOWING PROPOSED NEW CONSTRUCTION. <br /> 3.REMOVE AND LEGALLY DISPOSE OF THE FOLLOWING UNLESS OTHERWISE NOTED: ALL <br /> DEBRIS,CEILING TILE,FURNITURE,FIXED OR REMOVABLE EQUIPMENT,PIPING,PLUMBING, <br /> CONDUIT,LOOSE FINISH MATERIALS,DOORS,FRAMES,WINDOWS,PARTIT{ONS AND STAIRS ��ral Notes: <br /> AS SHOWN ON DRAWINGS UNLESS OTHERWISE NOTED.PUGET SOUND CLEAN AIR AGENCY All wak to be carried out in accordance with the US Intematia�Building Code,la� - � <br /> Building Codes and Safet�+Regula6ais,Water,Elec�rialy regulations�d aN otl�er <br /> TO SIGN OFF ON DEMOUTION. relevant Authorities requirernent concemed. <br /> 4.PRIOR TO CARRYING OUT DEMOLITION WORK,ALL EXISTING FRAMING MUST BE EXPOSED. a�wak to be carried out in a professiona�&watcmanship��ce manner according to the <br /> ARCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTIFIED FOR INSPECTION OF EXISTING plans&specification. �• <br /> CONDITIONS.REMOVAL OF EXISTING SUPPORTS FOR REMAINING FLOOR FRAMING WILL �not scale off the�awings uniess otherwise stated and use figured dimensions in <br /> preference. <br /> REQUIRE SHORING OF THESE MEMBERS AND ADDITION OF NEW BEAMS AND POSTS AS a�dmensions�e ro ne chedced&veritred on site berore tl,e cornrn�,�enc��y <br /> REQUIRED BY STRUCTURAL ENGiNEER.GENERAL CONTRACTOR SHALL PROVIDE ALL wak,a��dimensi«is&�evels are subject to fina�s�u�rey and set-art. <br /> NECESSARY SHORING AND WALL BRACING AND SHALL CARRY OUT ALL REVISIONS This drawirg 8 design is the piupeity of the design graip noted on this sheet and <br /> REQUIRED BY EXISTING FIELD CONDITIONS. should not be reproduced either in part or whde without the written consent of this firm. <br /> 5.REMOVE AL�FLOOR AREAS AND STRUGTURE WHERE NOTED ON DRAWINGS.NO NEW <br /> MASONRY OPENINGS ARE TO BE MADE OR STRUCTURE REMOVED PRIOR TO NOTIFYING CLIENT: <br /> �'' STRUCTURAL ENGINEER. <br /> �:� ✓,;,�"'f` - <br /> f ��� �"'`�� 6.LOCATION OF NEW OPENINGS ARE SHOWN ON DRAWINGS. <br /> � � �� �� 7.WHERE CONCRETE OR MASONRY WORK IS REQUIRED TO BE CUT,CUTTING SHALL BE DONE <br /> r " �;,, BY ABRASIVE,WHEELS,SAWS,OR CORNING.NO JACKHAMMERS WILL BE ALLOWED ON - . <br /> THESE AREAS UNLESS APPROVED BY THE ARCHITECT.ALL NEW WORK NEEDS TO BE DONE � <br /> � �� �� DURING OFF HOURS. � <br /> 8.ITEMS OF SALVAGEABLE VALUE TO CONTRACTOR MAY BE REMOVED FROM STRUCTURE ,: <br /> WITH OWNER APPROVAL PRIOR TO REMOVAL AS WORK PROGRESSES.SALVAGED ITEMS <br /> , f�° � MUST BE TRANSPORTED FROM SITE AS THEY ARE REMOVED. <br /> � 9.D0 NOT CLOSE OR OBSTRUCT STREETS,WALKS,OR OTHER OCCUPIED OR USED FACILITIES <br /> �--..-_ WITHOUT PERMISSION FROM AUTHORITIES HAVING JURISDICTION.PROVIDE ALTERNATIVE <br /> _ ROUTES AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS IF REQUIRED BY GOVERNING <br /> � - REGULATIONS. <br /> ' 10.PROVIDE RAILS AND OTHER PROTECTIONS REQUIRED BY OSHA AND APPLICABLE BUILDING <br /> � ���_t � '� CODES. <br /> ��`r�"� 11.PROTECT EXISTMG FINISHES,TRIM,AND FIXTURES TO REMAIN I.E.WOOD FLOORS, - <br /> � <br /> � RUNNING TRIM DECK HANDRAILS,ETC... <br /> �,, 12.ALL WORK NOTED TO BE REMOVED,CUT DOWN OR DISMANTLED SHALL BE DONE IN SUCH <br /> �,,, A MANNER AS TO MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE. ` <br /> 13.THE DEMOLITION CONTRACTOR SHALL HAVE THE SOLE RESPONSIBILITY OF VERIFYING <br /> CONDITIONS AT THE JOB TO PROVIDE FOR A SAFE AND ORDERLY PERFORMANCE OF THE <br /> WORK. �` <br /> "-"y==�-� 14.WORK UNDER THIS CONTRACT SHALL BE THE FULL RESPONSIBILITY FOR THE DEMOLITION <br /> ' CONTRACTOR;AND NO ACT,DIRECTION OR REVIEW OF ANY SYSTEM OR METHOD BY THE <br /> ARCHITECT OR HIS CONSULTANTS SHALL CHANGE OR EFFECT THE CONTRACTORS <br /> � RESPONSIBILITY IN THIS MATTER. <br /> . <br /> A �,-" 15.STORE ITEMS TO BE SALVAGED AS SHOWN AND PROTECT FROM DAMAGE. <br /> _� ��;:> � , 16.UNDER NO CONDITION SHALL ANY EXISTING FOUNDATION BE UNDERMINED OR ANY QR <br /> y`�`- STRUCTURAL MEMBER ALTERED IN ANY WAY THAT WILL ADVERSELY EFFECT THE EXISTING <br /> � WORK TO REMAIN. - <br /> 17.CAP ALL ABANDONED PLUMBING,GAS&ELECTRICAL LINES,ETC.IN ACCORDANCE WITH <br /> CODE <br /> 18.EXISTING HVAC TO REMAIN UNLESS OTHERWISE NOTED.DO NOT CUT CONTROL WIRE , <br /> BEFORE VERIFYING WITH THE HVAC CONTRACTOR. <br /> 19.REMOVE ALL WALL BASE WHERE NOTED,PREP WALLS TO RECEIVE NEW BASE. <br /> 20.REMOVE ALL FLOORING TRANSITION STRIPS NOT SCHEDULED FOR REUSE. ,, <br /> 21.VERIFY FURNITURE AND EQUIPMENT TO REMAIN AND STORE DURING CONSTRUCTION AS <br /> REQUIRED. Stamp: <br /> 22.SAFE-OFF ALL POWER PRIOR TO DEMOLITION. ; y� � -- <br /> 1 �``•� � } � . , e <br /> � � y •..� r <br /> n s �..:.�a ; <br /> � I(�I �"'c_� 4 <br /> 1 ��i y ��i;��� �A \ ,y � <br /> m �( � ' ; ._ , S;�aTt i��b..1S, r�,�3�" <br /> �� , J,J <br /> { ``���� 101 tl 1 <br /> �� �� ,a � � DEMOLITION LEGEND — %'�� � �� — <br /> �� ,� � <br /> I I \\�\\ 10 ; � � TYPICAL SYMBOL NOMENCLATURE: �� <br /> J �� D DENOTES DEMO FIXTURE <br /> � �,�', �� �°` — � � <br /> NOTIN CONTRACT <br /> � 90� b. <br /> ''� _ _ _ _ _ _ EXISTING PARTITION TO <br /> 10 � , �; BE REMOVED <br /> 3};: �- i i EXISTING MILLWORK <br /> �, � _ _ _ � TO BE REMOVED <br /> �--�—=" '�: • <br /> t, f, <br /> ��! 10 ,. <br /> � '; � /' '—' <br /> ,.,. \\�� � <br /> � \ ��t\� 101 <br /> `�,� �" - �� �\ �� , <br /> . <br /> � f/' � ,, �� �� _ _ __ <br /> .t'�� '� �� \� <br /> � �- <br /> ;;�' i `. � ���� _� .__.. __----,--:_.:._ _—_.__ _ —� 1 PERMIT SET REVIEW 01/04/18 <br /> . <br /> '�� �;� �, � _�```. ��° � � 7'-5 5/8" � ___ _ -� " REV DESCRIPTION DATE BY CHK <br /> . . . <br /> , ,,,� � - <br /> , <br /> ; t, •, l 6�,F , � . ti <br /> - � � -- <br /> > <br /> �� � <br /> , ,� . `-'�_ <br /> ; ,; r � _...__ <br /> �� ��� � ��� KEY NOTES : , <br /> :r , � �� � � <br /> ; , : . , <br /> , _____�_�.�� <br /> , . M- <br /> �y � <br /> . <br /> ,� ,F �� '' � N0. NOTE3 <br /> ` ``� ' <br /> . ��� ,�,, , ' � ;�� � t. , ��,�� r�, � �� � - '. <br /> „ <br /> ' ` �'�� � '� � ' �'` '; " D101 POWERIDATACDNNECTIONS S A - <br /> � � - � � 701 5th Ave.,Suite 673Q ' <br /> r F DEMOLISH EXISTING GWB PARTITIONS AND ASSOCIATED eattle WA 98104 US <br /> � , � � ;; t, <br /> +1 206 270 7000 <br /> � ��, � AS INDICATED,REMOVE ALL WIRING BACK TO SOURCE. <br /> , ;, � . , , <br /> ,o, ��� , ' ,,.., www.unispace.com <br /> �•t D102 DEMOLISH EXIStING WALL SIGNAGE THROUGHOUT. <br /> : —_ .___� _ <br /> , - ,., .- - <br /> ,. <br /> ;* � � �' ' - -�-- � ;'` ,/� ��< D103 SALVAGE EXISTING FURNITURE AND CASEWORK SCHEDULED FOR REUSE,VERIFY WITH <br /> • '. I' '`� <br /> ` ; � <br /> � OWNER. <br /> . `,;� ,��� /% + �''; � ;-�,- . .�,, ___ ___r____�.._,_J�""1 �_n Client/Project Name!�dress: <br /> . , ;. �,`� �t f. _; —.�` ,,, D104 DEMOLISH EXISTING GLASS DIVIDER WALLS THROUGHOUT. <br /> , ; ' -- <br /> ' `. r'� " '° ,, "' \l D105 OEMOLISH EXISTING WALLCOVERING THROUGHOUT. _ <br /> . ��!� D106 SALVAGE ALL FLUKE FOUNDER WALL FRAMES SCHEDULED FOR REUSE PER TENANT, � <br /> � VERIFY WITH OWNER. <br /> �---�` ,. '�.{ D107 DEMOLISH EXISTING RECEPTION DESK. FLU KE LOB BY • <br /> �' �i D108 DOOR AND HARDWARE TO BE DEMOLISHED.DOOR FRAME TO REMAIN, <br /> � 6920 SEAWAY BLVD, EVERETf,WA � <br /> a <br /> M <br /> � �. <br /> � C <br /> :,. ..., �. :: � 7 <br /> ._ � <br /> ��, � <br /> i\ Drawing Title: �, <br /> c <br /> � �I <br /> _ ���, � � o <br /> �� I'�� � � <br /> DEMOLITION PLAN - �, <br /> � - <br /> LEVEL 01 � <br /> U <br /> N � . <br /> C <br /> � <br /> 7 <br /> Status: � �� <br /> PERMIT REVIEW � <br /> � <br /> � <br /> � <br /> �rawn By: KNR Checked By:APC � <br /> N <br /> Scale: As indicated Date: 02/27/18 � <br /> ProjectNumber: ���-000��� � <br /> M <br /> O . <br /> DEMOLITION PLAN - LEVEL 01 Drawinq Number. Revision: � <br /> � <br /> SCALE: 1/8"=1'-0" � N <br /> � ' � <br /> � � <br /> 0 <br /> W <br /> � <br /> Z <br /> �� a .. <br />