� <br /> � <br /> PARTITION PLAN NOTES KeyPlan: <br /> 1.MAINTAIN ACOUSTIC AND/OR FIRE RATINGS AROUND RECESSED FIXTURES,PIPING, <br /> DUCTWORK,PENETRATIONS AND ALL OBSTRUCTIONS. <br /> 2.WHERE GYPSUM BOARD CElLINGS MEET WALLS HOLD CEILING BACK FROM THE FACE <br /> OF THE INTERSECTING WALL AND CAULK AIRTIGHT WITH A CONTINUOUS BEAD OF <br /> ACOUSTICAL SEALANT.WHERE NECESSARY,USE FOAM BACKER ROD TO PROVIDE A o 4' 8' �s' ` a � <br /> SURFACE AGAINST WHICH TO CAULK. <br /> 3.AT CORNERS,HOLD THE LAST LAYER OF GYPSUM BOARD FROM THE FACE OF THE <br /> INTERSECTING WALL SUCH THAT NO GWB LAYERS ARE CONTINUOUS BETWEEN 2 <br /> ADJACENT ROOMS AND CAULK WITH A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. General Notes: <br /> 4.USE FIRE RATED SEALANT AT FIRE-RATED PARTITIONS AS REQUIRED$Y CODE. '�W����m������'^'�the US Intemationai Building Code,local <br /> 5.MAINTAIN INTEGRITY OF EXTERIOR WALL CONTINUITY,ASSEMBLIES,INSULATION AND �������d Safety Regulations,wa�er,Eiecb;cuy reyuia�a,s and a�i aner <br /> relevant Authaities requirement concemed. <br /> FINISHES AS REQUIRED. A!I wak to be carried out in a professional&wakmanship Iike manner aocording to the <br /> 6.COORDINATE ALL MECHANICAL TRANSFER GRILLES AND RETURN AIR OPENtNG THAT ��&5��� <br /> OCCUR ABOUE THE FINISHED CEILING IN FIRE RATED AND ACOUSTICALLY TREATED ����e��e�������stated and use figured dimensions in � <br /> Preference. <br /> WALLS. PROVIDE FIRE DAMPERS WHERE INDICATED. PROVIDE RETURN AIR(CEILtNG ai��,�a,s a�e ro ne c�ed s��d o��t�aer«e n,e�,�o�»�,t or�,y <br /> PLENUM)OPENINGS WHERE REQUIRED BY THE MECHANICAL DRAWINGS. wak aN dimensions&�evels are subject to final survey and setart. <br /> 7.ALL FIRE RATED PARTITIONS MUST CONFORM TO MINIMUM REQUIREMENTS OF THE This drawing&design is the property of ihe desiyn group noted on ihis sheet and <br /> LISTED TESTED ASSEMBLY UNLESS MORE STRINGENT REQUIREMENTS ARE should not be re�xoduced either in part ar whde without the written consent of this firtn. <br /> DE5IGNATED BY DETAIL. <br /> 8.ALL ACOUSTICA�STC RATED PARTiTION CONSTRUCTION EXTENDING TO THE BOTTOM CLIENT: <br /> ' ''` OF STRUCTURE SHALL HAVE ALL PENETRATIONS AND INTERSECTIONS SEALED AIR <br /> r1 �� 9.FIRE RATED SEALANT SHALL�BE USED AT FIRE RATED PARTITIONS.ALL RECESSED <br /> BOXES SHALL BE SEALED AND Rl3NNERS SHALL BE SET IN 2 BEADS OF SEALANT. <br /> 10.ALL ROOMS WITH PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH WATER <br /> RESISTANT GYPSUM BOARD UON <br /> � 11.COORDINATE PARTITION CONSTRUCTION WITH FINISH PLANS. <br /> _ 12.ALL GYPSUM BOARD PARTITIONS SUPPORTiNG WALL HUNG CABINETS,SHELVING, : <br /> ' � OVERHEAD BINS,TELEVISION MOUNTS,FURNITURE,ETC.SHALL HAVE 20 GAUGE STUDS <br /> SPACED AT 16"O.C.WITH FLAT GAUGE BLOCKING. <br /> 13.BRACE ALL METAL STUD PARTITIONS AT ALL LOCK SIDES OF DOORS,WHERE DUCTS <br /> . INTERFERE WITH METAL STUDS GOING TO UNDERSIDE OF SLAB ABOVE AND WHERE <br /> CALLED FOR ON DRAWINGS. <br /> \1��� �/ 10 14.PROVIDE CONTROL JOINTS IN GYPSUM BOARD PARTITION RUNS EXCEEDING 30'OR <br /> ' �r,, �P ( b� �;;Y'' MORE AND AT ALL INTERSECTIONS WITH BUILDING CORE,EXTERIOR WALLS,COLUMNS <br /> � AND WHERE RECOMMENDED BY MANUFACTURERS'WRITTEN INSTRUCTIONS. <br /> ,�� 15.TAPE AND SPACKLE ALL JOINTS IN DRYWALL,INCLUDING JOINTS ABOVE THE CEILING. <br /> 16.PROVIDE DOUBLE STUDS AT BOTH JAMBS AND HEADER OF ALL DOOR FRAMES. <br /> � �o� <br /> ' PARTITION PLAN LEGEND <br /> o '°`22 ,* � <br /> � , � <br /> C� �° �� �.� ,, � L� �� � o <br /> FEC NOT IN CONTRACT <br /> 103 101 f <br /> � F21 <br /> � <br /> � EXISTING DOOR TO REMAIN <br /> � , <br /> 1, A4-200 '� <br /> 3 �,.T,;� ,, NEW DOOR � <br /> Stamp: <br /> I <br /> _ �— , � FIRE RATING �' c:� , � `- _.. . <br /> ' ' a� , I � DOOR NUMBER �� � i : <br /> �' FLOOR NUMBER � � � '���"''`-�°�a � <br /> , , F21 I. _ . � <br /> • 1'��''� r�' `n 1�: � <br /> G � A3 DENOTES PARTITION TYPE.SEE rr,.�,}�r ,,, g <br /> t�9i�JlVT�Y:�t (�Y��(4i� <br /> i PARTITION TYPE SHEET A5-200 <br /> F21 /�`� VESTIBULE � INDICATES NEW PARTITION � <br /> s / ♦ A4-2oo � ' ' 100 l - <br /> � EXISTING PARTITION TO REMAIN. �� �'/ �� <br /> ' '��, � `� 100A� ` <br /> �� � , / � <br /> � �` ' / NEW MILLWORK.SEE MILLWORK ELEVATIONS AND DETAILS. <br /> �i � � '� <br /> Y � ' ` �` _ = INDICATES NEW GLASS PARTITION <br /> � `� � 100B0 <br /> � � �` � � — — FIRE EXTINGUISHER CABINET <br /> � � ����� � � � FEC <br /> �� � �. ________. ___� <br /> � — � <br /> HALLWAY�� `� � <br /> a.� <br /> i 102 ♦ 3 A4-200 <br /> a <br /> � S . �� r________� <br /> , , ,��� ; ��� <br /> � TYP H �� � � � � � � � � ' <br /> �,; �� � � <br /> � � /1010 � , . � <br /> , v 'o, � : . 2 <br /> � , <br /> I �i � � � 6-1 4 A4-200 , <br /> ,�``�.� �,, , _ _ �- � � ; � <br /> , / ��,� � ,,,�' �� F21 <br /> � r: <br /> �j �2 L_______ J <br /> . -�� � '9 - -- <br /> /� i ,. �jCy � .,._. _ _ _ -- /�` 1 PERMIT SET REVIEW 01/04/18 <br /> j. , �.�..� %� ; 1 _._.�_:��._._..�_____�,.r__.�.� � <br /> � � REV DESCRIPTION DATE BY CHK <br /> , � <br /> . ; <br /> /�, . � r,/ �_,' � �M1 <br /> �� }// � �^. �`�".ic---�--.-.. <br /> �� KEY NOTES <br /> � i � '� <br /> , . � <br /> f/ 4 ��� �� <br /> �� �.� <br /> l� . >� .. .... _ _s____ ' . <br /> ,' � ;;, <br /> /�� , ,�`� ' N0. NOTES <br /> �: i � ,, . �, <br /> �1 <br /> ,,�o, f// �,. ,:� . �+.: ., r. � _ . .... . <br /> � ' f ,-., 01 5th Ave., Suite 6730 <br /> .T , . . ... . <br /> . ,_. , �.ss� . <br /> /� ��' � � '� � ' ��.< .--� �� �� ' � ��'. INISH S .: <br /> , — <br /> A101 THIS SIDE OF WALL TO HAVE LEVEL 5 F . 7 eattle WA 98104 USA <br /> +1 206 270 7000 <br /> �' !' �,� , � �•` , � <br /> ,� � <br /> , ' , `` �`'�,. ' ��;, A102 RELOCATE EXISTING DiSPLAY CASES. <br /> ' � �,,� "��u�:� � 'r r � L A103 PROVIDE AND INSTALL NEW FIRE EXTINGUISHER CABWET AND FiRE EXTINGUISHER TO �•unispace.com <br /> . <br /> � `�� � �'��"�"""`���"` '�� ,� `�_:� MATCH OWNER STANDARDS. <br /> `/ r �;�, <br /> : � � � �, <br /> � (f r� t Client/Project Name!Address: <br /> '�,��; c 4 'L^�� <br /> �� ' �i'''� `` <br /> .l� <br /> �- <br /> % <br /> ��< , �i� <br /> FLUKE LOBBY <br /> ' � 6920 SEAWAY BLVD, EVERETT,WA � <br /> a°�� �� � � <br /> °� � � ,. <br /> � �� ; <br /> {-.`~} �, , y `� Drawing Title: � <br /> ���` � <br /> c <br /> i a� <br /> i a <br /> 0 <br /> � <br /> PARTITION PLAN - �, <br /> � <br /> LEVEL 01 � <br /> U <br /> N <br /> C � <br /> N <br /> � <br /> 7 <br /> U <br /> O <br /> Stat�s: pERMIT REVIEW � �" <br /> � <br /> � <br /> � <br /> �rawn By: KNR Checked ey:APC � <br /> w <br /> Scaie: As indicated Date: 02l27/18 ' <br /> U <br /> Project Number: �EA-00048A � <br /> 0 <br /> PARTITION PLAN — LEVEL 01 � Drawinp Number: Revision: � <br /> SCALE: 118"=1'-0" � <br /> � <br /> 0 <br /> N . <br /> N <br /> - � y <br /> 0 <br /> W <br /> F <br /> Z <br /> �� � <br /> a " <br /> � <br />