Laserfiche WebLink
Stantec Consulting Services Inc. <br /> 4100 194th Street SW,Suite 400 <br /> Lynnwood WA <br /> � � � � e � � s � � <br /> REFER TO E8.03 Tel. 206.667.0555 <br /> REFER TO E8.02 www.stantec.com <br /> Copyright Reserved <br /> ELECTRICAL EQUiPMENT IDENTIFICATION LEGEND GENERAL NOTES. NOTscalethtedrawlinerifyandberesponsibleforalldimensions.DO <br /> g-any errors or omissions shall be reporfed to <br /> Stantec without delay. <br /> 1HESE NOTES APPLY TO ENTIRE PONIER RISER, SHEETS E8.02 THRU E8.11 The Copyrights to all designs and drawings are the properfy of <br /> T-F�N H� Stantec.Reproduction or use for any purpose other than that <br /> � authorized by Stantec is forbidden. <br /> PANEL NUMBER �• � FAULT CURRENTS SHOWN REPRESENT SIMULAlED 30 BOLTED FAULTS <br /> UNLESS OTHERWISE NOiED. SEE FLAG NOTE FOR EXCEPTtON. <br /> VOLTAGE CO C1S U ItC1 C1 tS <br /> H - 480Y/277V <br /> L - 208Y/120V <br /> HDP - 480Y/277V DISTRIBU110N <br /> �� N'� NORMAL BRANCH FLAG NOTES: <br /> R - ROOFTOP C - CRITICAL BRANCH <br /> 10- LEVEL 10 X - UFE SAFETY BRANCH THESE NOiES APPLY TO ENTIRE POWER RISER, SHEETS E8.02 THRU E8.11. <br /> 9 _ ��� 9 E - EQUIPMENT BRANCH � FEEDER SCHEDULES APPLY TO ALL fEEDERS BELOW 600 VOLTS. UT1lJZE THIS <br /> 8 _ �� $ 0 - OPTIONAL BRANCH � <br /> FlRE PUMP CONTROLLER BY � _ �yE� � U - UPS BRANCH SCHEDULE FOR RISERS SHOWN ON SHEETS E8.02 THRU E8.13 AND E8.20. Legend <br /> MECHANICAL CONIRACTOR <br /> SEE SHEET E8.01 6 - LEVEL 6 � FAULT CURRENT REPRESENTS S�MULATED SIN(�E UNE TO GROUND BOLTED <br /> 5 - LEVEL 5 FAULT. SLG FAULT VALUE HIGHER THAN 30 BOLTED FAULT AT TNIS BUSS. <br /> FOR CONIINUATION 4 - LEVEL 4 <br /> A2G3 /-FlRE PUMP, FP-1 3 - LEVEL 3 � �6 AWG BONDING JUMPER BETVVEEN PANELS SERVING PATIENT CARE AREAS <br /> � 2 - LEVEL 2 <br /> 1 - LEVEL 1 ON THIS LEVEL <br /> A2G3 G - LEVEL B1 <br /> >� B - LEVEL B2 <br /> SEE SHEET E8.00 <br /> FOR CONT1NUAl10N �� BUILDING <br /> D - CANCER CENTER <br /> AL5 F - D-WING <br /> G - PARKING GARAGE <br /> TYPE P - U11L1TY PLANT <br /> T - TRANSFORMER <br /> A2J5 <br /> T-FBNL6 �5 ,y <br /> 480V 20 Y/120V �'�9 <br /> P�a K 13 RAiED DIST PAN PANEL PANEL T PANEL � PANEL <br /> FBNH2 FBNL6 FBNL7 FBNL8 i FBNL9 i FBNL10 <br /> CC3 I ATK75 <br /> i i <br /> � � SCHEDULE NOTES: <br /> - � � <br /> Notes <br /> - - - � - - - -� 1• CONDUIT SIZING BASED ON RIqD GALVANIZED S1EEL OR PVC SCH. 40 <br /> �'1 � CONDUIT AND WIRE TYPE 1NHN/1HWN-2 OR XHHW WIRE, TAKING INTO <br /> �,�r� h� S `s>�, ACCOUNT BOTH CONDUIT FlLL AND JAMB RATIO. CONDUIT AND RACEWAY <br /> �" FOR ALUMINUM CONDUCTORS (AI) SIZED FOR COMPACT TYPE CONDUCTORS. <br /> CONFlRM CONDUtT FlLL AND JAM RATIOS FQR FEEDER GONFlGURATIONS <br /> OTHER THAN 1HOSE SHOWN. <br /> �'5 2. AMPACITiES LISTED ARE BASED ON THE FOLLOWING TAKEN FROM TABLE <br /> TYPICAL 310-16. <br /> A. 75' RATING FOR 3W AND 4W FEEDERS. <br /> �3 B. 90' RAl1NG FOR 5W FEEDERS DE-RATED TO 80% WHERE PREDOMINATELY <br /> HARMONIC CURRENTS ARE PRESEI�IT. NEUTRALS Z �t/0 ARE <br /> PARALLELED ON 5W FEEDERS. <br /> T-FBCL4 r��.`° 3. INCREASE RACEWAY SIZE FOR OTHER TYPES OF RACEWAYS AND DIFFlCULT <br /> 225 KVA �o' OR LONG PULLS. <br /> 480V 208Y/120V <br /> LTG PNL PANEL K 13 RATED DIST. PANEL ' �13� 4. GROUND NARE SIZE INCREASED FOR PARALLEL CONDUCTOR RUNS PER NEC <br /> LCP-BS FBCH2 PANEL FBCL3 32HP AC-1 EF-7 FCU-608 FCU-BOt FCU-B10 FCU-611 SP-2 PBS-1 FCU-B12 JP-t EF-10 TABLE 250-�22. <br /> I FBCL4 AP4 A2M4 <br /> O <br /> AJ4 = N <br /> 16.7 KVA BATTERY a o�,' Q a 70A-3P <br /> INVERTER � <br /> ��``� m "� S � m <br /> h <br /> ��� 3�4��� 4 ��� � �2� $ v^.' ATK22 AL5 � o <br /> P�a ' � A2M4 � <br /> M <br /> FBUH1 <br /> CA3 <br /> PANEL <br /> FBXHDP2 <br /> I I � r ^ <br /> � ( 2000AF 800AF �° 225AF /° 225AF 'WOAf 225A� �2�AC�E� SPA� �$2pARE� $40�OAT 600AT 1000AT � N � 3000AT lOAT 30A� 20A� 20A 20A� 20A� 20ATF 20A� 100AT 20ATF 20A� 20A� �SPARE � SPARE SP�ACE ��� SPA� <br /> �0 1600AT � 600AT SPARE � SPARE SPACE SPACE � � � � m � � � ( � ( � ( � � � � � � ( <br /> ti1��� � � <br /> � <br /> FBCHDP2 FBNHDP2 FBEHDP2 <br /> AJ4 C4N4 1600A 480Y/277V, 3�, 4W 1200A 480Y/277V, 30, 4W A�4 3000A 480Y/277V, 30, 4W � � �� <br /> t 00,000AIC 100,OOONC 100,000AIC <br /> ATS-X2 ATS-C2 ATS-02 ATS-E2 <br /> 225A/4� 1600A/4P 1200A/4P 3000A/4P � _� F E E D E R S C H E D U L E <br /> LIFE SAFETY CRITICAL NORMAL/OP110NAL EQUIPMENT <br /> 37,567 74,743 FEEDER N0. CONDUCTORS (COPPER AND COMPACT ALUMINUM) AMPAqTY <br /> 26,878 ¢?�S q� = qj CONDUIT IMRE NOTE 2 <br /> CA4 1-1/4' 4 - �l4, 1�8 G. 85 <br /> �3,2ao - cn3 ,' w 3 - �a, ,�s c. 85 , TRANSFORMER SECONDARY FEEDER SCHEDULE <br /> CB4 1-1/4 4 - #2. 1 ,�6 G. 115 <br /> 2 43,617 3000A BUSWAY Q . <br /> 80,620 3 CB3 1-1/4 3 - �2, 1 ;�6 G. 115 480 TO 208Y 120V, THREE PHASE TRANSFORMERS <br /> m CC5 2" 3 - �1, 2�1�0 N, 1�6 G. �20 SECONDARY kVA CONDUCTORS (COPPER AND COMPACT ALUMINUM) GROUNDING <br /> a CC4 1-t/2" 4 - �t, 1 G. 130 N�' RATING FLA CONDUIT NARE CONDUCTOR C�PACITYR <br /> � CXX=Cu AXX=A1 <br /> AJ4 C4N4 A4M4 AJ4 C4N4 A4M4 $ CC3 1-1/2" 3 - #1, 1 �6 G. 130 CT3 3 8 1 2" 4 - 2, t G. 8 20 <br /> M AF5 2' 5 - #3�0, 1 �4 6. 140 CT6 6 17 3 4' 4 - 0, 1 G. 8 30 <br /> AF4 2" 4 - /3/0, 1 �4 G. 155 CT9 9 25 3 4' 4 - , 1 G. S 50 <br /> CTt5 15 42 1' 4 - , 1 G. 8 65 <br /> AF3 1-1/2" 3 - �3/0, 1 ,�4 G. 155 CT30 30 83 1 1 Y 4 - 2, 1 G. 8 115 _ <br /> AG5 2-1�2" 5 - �4�0, 1 �4 G. 164 AT45 45 125 2' 4 - 0, 1 G. 4 155 <br /> AG4 2" 4 - #4/0, 1 �4 G. 180 AT75 75 208 2-1 2' 4 - 300kcm1, 1 0 G. 1 0 230 <br /> LS CR NORMAL/�T EQ LS CR NORMAL/OPT EQ AG3 2' 3 - �4/0, 1 �4 G. 180 AT112 1125 312 3-1 2' 4 - 600kcmil, 1 0 G. EA. 3 0 340 <br /> � ) AH5 2-1/2' 5-250kcmil, 1 #4 G. 184 AT150 150 416 2 2-1 2' 4 - 300kcm�, 1 0 G. EA. 3 0 4&0 <br /> REFER TO SHEET E8.00 REFER TO SHEET E8.01 AH4 2-1/2' 4-250kcmil, 1 �4 G. 205 AT225 225 625 2 3' 4 - 600kcmil, 1 0 G. EA. 4 0 680 <br /> FOR CONIINUATION FOR CONi1NUATION AH3 2' 3-250kcmil, 1 ,�4 G. 205 AT300 300 833 4 3" 4 - 350kcm1, 1 0 G. EA. 4 0 1000 <br /> AT500 500 1388 5 3-1 2' 4 - 600kcm1, 1 cm8 G. EA. 250 1700 <br /> CH5 3" . 5-250kcmil, 1 �4 G. 232 <br /> AJ5 3� 5-300kcmil, 1 ,�4 G. 204 480 TO 208Y 120V, THREE PHASE TRANSFORMERS K-Rated <br /> AJ4 2-1/2" 4-300kcmil, 1 �2 G. 230 SECONDARY CONDUCTORS (COPPER AND COMPACT ALUMINUM) GROUNDING <br /> AJ3 2" 3-300kcmil, 1 2 G. 230 N0. kVA ELECTRODE CONDUCTOR <br /> CXX=Cu AXX=N �T�NG FLA CONDUIT WIRE CONDUCTOR AMPACITY <br /> AK5 3� 5-350kanil, 1 �2 G. 224 CTK3 3 8 1 2" 3 - 2, 1 N. 1 G. 8 20 <br /> AK4 2-1/2' 4-350kcmil, 1 �2 G. 250 CTK6 6 17 3 4" 3 - 0, 1 N, 1 G. 8 30 <br /> AK3 2-1/2' 3-350kcmil, 1 �2 G. 250 CTK9 9 25 1' 3 - , 1 N, 1 G. 8 44 <br /> CMt 5 15 42 1 1 4" 3 - , 1 N, 1 G. 8 60 <br /> AL5 3'� 5-400kcmil, 1 �2 G. 244 CTK30 30 83 1 1 2" 3 - 2, 1 0 N, t G. 6 104 <br /> AL4 3� 4-400kCf1111, 1 �2 G. 2�� ATK45 45 125 2 1 2� 5 - 0, 1 G. 2 164 R'G'VISIOCI BY Appd. YY.MM.DD <br /> AL3 2-1/2� 3-400kcmil, 1 ,�2 G. 270 ATK75 75 208 3" 5 - 350kcm1, 1 0 G. 1 0 224 <br /> AM5 3 1/2" 5-500kcmil, 1 �2 G. 280 ATK112 1t2.5 312 5" 5 - 750kcm�, 1 0 G. EA. 3 0 348 <br /> AM4 3'� 4-500kcmil, 1 �2 G. 310 AM150 150 416 2 3-1 2` 5 - 500kcmil, 1 0 G. EA. 4 0 560 <br /> AN3 3" 3-500kcmil, 1 �2 G. 310 ATK225 225 625 2 5' 5 - 750kcm1, 1 0 G. EA. 4 0 696 <br /> AN5 3-1/2" 5-600kcmil, 1 �2 G. 308 AiK300 300 833 4 3-1 2' 5 - 500kcm�, 1 250kcm1 G. EA. 250 1120 <br /> AN4 3-1/2" 4-600kcmil, 1 �1 G. 340 AiK500 500 1388 6 4" 5 - 600kcmil, 1 cmN G. EA. 250 1848 <br /> AN3 3' 3-600kcmil, 1 �'1 G. 340 CONSTRUCTION DOCUMENTS NCA MDJ 18.12.13 <br /> A2G3 (2) 2-t/2' 3-�4/0, t �1G EA. 360 <br /> Issued BY Appd. YY.MM.DD <br /> AP4 4' 4-750kcmil, 1 �1 G. EA. 385 <br /> AP3 3-1/2" 3-750kcmil, 1 ;�1 G. EA. 385 <br /> A2J5 (2) 3' 5-300kcmil, 1 �1 G. EA. 408 NCA MDJ NCA 18.12.13 <br /> A2K5 (2� 3" 5-350kcmil, 1 �1�0 G. EA. 448 Dwn. Chkd. Dsgn. YY.MM.DD <br /> A2K4 (2) 3� 4-350kcmil, 1 �1/0 G. EA. 500 <br /> Q A2K3 (2) 2-1/2" 3-350kcmil, 1 �1/0 G. EA. 50o Permit-Seal <br /> w A2M4 (2) 3" 4-500kcmil, t �3/0 G. EA. 620 �� D . J <br /> Z A2M3 (2) 3' 3-500kcmil, 1 �3/0 G. EA. 620 ,�� pF WAS�`4�' <br /> � A2N4 (2) 3-1/2' 4-600kcmil, 1 ;�3/0 G. EA. 680 � ��' � ���-�J1 <br /> �� � � <br /> m A2N3 (2) 3 3-600kcmil, 1 /3/0 G. EA. 680 � � �, <br /> � A3L4 (3) 3' 4-400kcmil, 1 �3/0 G. EA. 810 <br /> ,�., A3L3 (3) 2-1/2' 3-400kcmil, 1 �3/0 G. EA. 810 <br /> � A3N4 (3) 3-1/Y 4-600kcmil, 1 �4/0 G. EA. 1020 ��,o � 38180 ,� <br /> � A3N3 (3) 3" 3-600kcmil, 1 �4/0 G. EA. 1020 ��`�S�ONAL ��'1� <br /> � A4M4 (4) 3' 4-500kcmil, 1 �3350 G. EA. 1240 t <br /> �i A4M3 (4) 3" 3-500kcmil, t �350 G. EA. 1240 �,Z'i.�jj'�� <br /> � C4N4 (4) 4" 4-600kcmil, 1-250kcmil G. EA. 1680 <br /> Client/Project <br /> � A5N4 (5) 3-1/2' 4-600kcmil, 1 �4400 G. EA. 1700 <br /> � A5N3 5 3• �-sook«►,,, � �oo c. Ea »oo PROVIDENCE REGIONAL MEDICAL <br /> � A6N4 �s� 3-,�2~ a-sook«„��, , �soo c. En. zo4o CENTER EVERETT - COLBY CAMPUS <br /> m (s) 3' 3-soo��„�i, � �soo c. EA. 2040 <br /> A6N3 <br /> � <br /> LEVEL B2 <br /> o .__ � -�_ _.. ___ __ . __._..��m.�.�. <br /> _ _.. _� �_ . .�,.�w.�p��.�u�...�.�,�_�..�,�������..v.���u�.��....�,w��.�.u..����..�..�.�.�..�..�.,�.�.��.�.�.,wv.Y.._�¢�..k.�����_.�.��..��r�...��,�_��,�u_�w.,.�.�..�.�,����.�.��t.�.��.m�,.,.�.,..�,.�u_�,� _��,:W z.��..�,.� �_�.�,r�r ��r,..��,���_���.�,a�.���,�z_.� �a����,�k.��a��M�.���s�.�.:_�,�����.�..�,���.�.z��e�u�.,.��_�„�sM.�.��.��6_w�.u,,��.x.��.��x�...._.���,�,..�,..��a�..�.��,���.��,�.�.�..��.�_� u.��.z.�.�..�,��,,...�..��., .s���,�..0 ��._,��vr.�...����_..�..��� ����mvh���..w �,.�x.��,��.����n�����,��.,...pF�.�_.y��..,�.�.�.�s.�.��.kau.�F�.�a�u_�xr_�,�,���...v_w_a�H NU MED # REPL EMENT <br /> a � . � _ . __ C 3 AC <br /> U N <br /> / <br /> n <br /> � <br /> O) <br /> N <br /> EVERETT, WA <br /> � <br /> O <br /> N <br /> > <br /> Title <br /> � D-WING POWER RISER DIAGRAM <br /> Q <br /> � <br /> � LEVEL B2 SOUTH WING <br /> N <br /> / <br /> a. <br /> � <br /> 0 <br /> Y Project No. Scale <br /> � <br /> 3 204820937 N O N E <br /> � <br /> � Drawing No. <br /> 0 <br /> � <br /> 0 <br /> r� <br /> N FOR REFERENCE ONLY <br /> ; E8.02 <br /> , <br /> ORIGINALSHEcT-�CH_l <br />