Laserfiche WebLink
1 9-29.12(4) Re-Enterable Splice Enclosure <br /> 2 Re-enterable splice enclosures shall use either dielectric grease or a flexible resin <br /> 111 3 contained in a two-piece plastic mold. The mold shall either snap together or use stainless <br /> 4 steel hose clamps. <br /> 5 <br /> ' 6 <br /> 7 9-29.12(5) Vinyl Electrical Tape for Splices <br /> Vinyl electrical tape in splicing applications shall meet the requirements of MIL-I-24391C. <br /> 8 <br /> ' 9 9-29.12(1) Illumination Circuit Splices <br /> 10 This section is revised to read: <br /> 11 <br /> 12 Underground illumination circuit splices shall be solderless crimped connections capable of <br /> 13 securely joining the wires, both mechanically and electrically, as defined in Section 8- <br /> 14 20.3(8). Aerial illumination splices shall be solderless crimp connectors or split bolt vice- <br /> 15 type connectors. <br /> ' 16 <br /> 17 9-29.12(1)A Heat Shrink Splice Enclosure <br /> 18 This section is deleted in its entirety. <br /> 19 <br /> 20 9-29.12(1)B Molded Splice Enclosure <br /> 21 This section is deleted in its entirety. <br /> ' 22 <br /> 23 9-29.12(2) Traffic Signal Splice Material <br /> 24 This section is revised to read: <br /> 25 <br /> ' 26 Induction loop splices and magnetometer splices shall use an uninsulated barrel-type <br /> 27 crimped connector capable of being soldered. <br /> 28 <br /> ' 29 9-29.13(10)D Cabinets for Type 170E and 2070 Controllers <br /> 30 The first sentence of item number 4 is revised to read: <br /> 31 <br /> ' 32 <br /> 33 A disposable paper filter element with dimensions of 12" x 16" x 1" shall be provided in lieu <br /> of a metal filter. <br /> 34 <br /> 35 Item number 6 is revised to read: <br /> 1 36 <br /> 37 6. LED light strips shall be provided for cabinet lighting, powered from the Equipment <br /> 38 breaker on the Power Distribution Assembly. Each LED light strip shall be <br /> 39 approximately 12 inches long, have a minimum output of 320 lumens, and have a color <br /> 40 temperature of 4100K (cool white) or higher. There shall be three light strips for each <br /> 41 rack within the cabinet. Lighting shall be ceiling mounted — rack mounted lighting is not <br /> ' 42 <br /> 43 permitted. Light strips shall be installed in the locations shown in the Standard Plans. <br /> Lighting shall not interfere with the proper operation of any other ceiling mounted <br /> 44 equipment. All lighting fixtures above a rack shall energize automatically when either <br /> 45 door to that respective rack is opened. Each door switch shall be labeled "Light". <br /> ' 46 <br /> 47 Item number 7 is revised to read: <br /> 48 <br /> City of Everett Page AM-139 Amendments <br /> Everett Station 80 Stall Parking Expansion June 2019 <br />