Laserfiche WebLink
City111 <br /> of Everett <br /> 013223 - 3 <br /> 3600 Smith Street Clean Up <br /> 2. Calculate and measure required dimensions within indicated or recognized <br /> tolerances. Do not scale drawings to determine dimensions. Inform the personnel <br /> engaged in construction activities of marked lines and levels provided for their use. <br /> As construction proceeds, check every major element for line, level and plumb. <br /> 3. Provide stakes as required by various sections of these specifications and as <br /> ' required for accurate construction. <br /> 4. Record deviations from required lines and levels and advise the Owner when <br /> deviations that exceed indicated or recognized tolerances are detected. On project <br /> record drawings record deviations that are accepted and not corrected. <br /> 3.2 AS-BUILT INFORMATION: <br /> A. Contractor shall locate and establish grade of completed construction for use in <br /> preparing as-built documents of the project. As-built information is required for, but not <br /> limited to, the following: <br /> 1. Corners and/or center lines, and benchmark elevations of major structures. <br /> 2. Center lines and grades of roads, paths, vehicle gates. <br /> 3. Survey shall be completed utilizing State (Washington) Plane Grid coordinate <br /> System. <br /> 4. Vertical datum shall be referenced to NAVD "88" datum <br /> END OF SECTION O 01 32 23 <br /> I <br /> I <br /> t <br /> r <br /> I <br /> 1 <br /> 01 32 23 - 3 SURVEY AND LAYOUT DATA <br /> I <br />