Laserfiche WebLink
I <br /> 1 <br /> 2 9-05.3(1)C Age at Shipment <br /> 3 The last sentence of the first paragraph is revised to read: <br /> I4 <br /> 5 Unless it is tested and accepted at an earlier age, it shall not be considered ready for <br /> 6 shipment sooner than 28 days after manufacture when made with Type II portland cement <br /> 7 or blended hydraulic cement, nor sooner than 7 days when made with Type III portland <br /> I <br /> 8 <br /> 9 cement. <br /> 10 9-05.7(3) Concrete Storm Sewer Pipe Joints <br /> 11 The second sentence is revised to read: <br /> 12 <br /> 13 The joints and gasket material shall meet the requirements of ASTM C990. <br /> I 14 <br /> 15 9-05.7(4)A Hydrostatic Pressure on Pipes in Straight Alignment <br /> 16 The first sentence is revised to read: <br /> 17 <br /> I18 Hydrostatic pressure tests on pipes in straight alignment shall be made in accordance with <br /> 19 the procedure outlined in Section 10 of ASTM C990, except that they shall be performed <br /> 20 on an assembly consisting of not less than three nor more than five pipe sections selected <br /> I <br /> 21 <br /> 22 from stock by the Engineer and assembled in accordance with standard installation <br /> instructions issued by the manufacturer. <br /> 23 <br /> I 24 9-05.24(1) Polypropylene Culvert Pipe and Storm Sewer Pipe <br /> 25 This section is revised to read: <br /> 26 <br /> 27 Polypropylene culvert and storm sewer pipe shall conform to the following requirements: <br /> I <br /> 28 <br /> 29 1. For dual wall pipe sizes up to 60 inches: ASTM F2881 or AASHTO M 330, Type <br /> 30 S or Type D. <br /> I 31 <br /> 32 2. For double or triple wall pipe sizes up to 60 inches: ASTM F2764. <br /> 33 <br /> I <br /> 34 3. Fittings shall be factory welded, injection molded, or PVC. <br /> 35 <br /> 36 9-05.24(2) Polypropylene Sanitary Sewer Pipe <br /> 37 This section is revised to read. <br /> 38 <br /> 39 Polypropylene sanitary sewer pipe shall conform to the following requirements: <br /> 40 <br /> I 41 1. For pipe sizes up to 60 inches: ASTM F2764. <br /> 42 <br /> 43 2. Fittings shall be factory welded, injection molded, or PVC. <br /> I <br /> 44 <br /> 45 9-06.AP9 <br /> 46 Section 9-06, Structural Steel and Related Materials <br /> I47 January 7, 2019 <br /> 48 9-06.5 Bolts <br /> 49 This section's title is revised to read: <br /> I 50 <br /> CITY OF EVERETT AMENDMENTS <br /> PACIFIC AVENUE TO INTERURBAN TRAIL BICYCLE SAFETY PROJECT 8/12/2019 <br /> I <br /> STATE FUND#HLP PB17(014); COE#PW3688 Page AM-119 <br />