2211 W CASINO RD 2017 ACCESS LASER Plans 2022-12-29 (3)
>
Address Records
>
W CASINO RD
>
2211
>
ACCESS LASER
>
Plans
>
2211 W CASINO RD 2017 ACCESS LASER Plans 2022-12-29 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2022 10:36:30 AM
Creation date
10/21/2019 10:51:47 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2211
Tenant Name
ACCESS LASER
Permit
B1710-045
Year
2017
Notes
2ND FLOOR ADDITION NEW LAB
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . . . . . . , � . � . � . � .. . . . .. . � � . . � � .. . � . . . . ;' <br /> . :� . . . . . . . . . � . . . . . . . , <br /> . . . . . . � � . . � � .:� . . � ' . . . . . . <br /> . GENERAL NOTES <br /> � � 1. NOT USED. : , <br /> _ 4'-7%" 1 HR HORIZONTAL LID FIRE BARRIER <br /> OR EXTEND SHAF"f WALLS TO <br /> SAFETY BEAM UNDERSIDE OF METAL ROOF DECK <br /> ,� TOP OF PANEL . <br /> '.� E D.4 D C B q EL. 30'-0" .1. <br /> - \ - KEYED NOTES <br /> TOP OF PANEL - �, , <br /> . . O1 NOT USED. <br /> =_ � <br /> o � <br /> � STAIR TO E4UIPMENT m <br /> ACCOUNTING OPEN OPEN � ��, OPEN PLATFORM WITH 42" HIGH _ � '. <br /> OFFICE SPACE � � � SPACE , � SPACE GUARDRAIL AND TOE KICK. � � <br /> " � 203 200 � � � � 208 , j 210 SEE 3/A201 N ,� <br /> � o <br /> - FUTURE SECOND FLOOR �\ � \ \`�.,/ o <br /> - .. _ � <br /> 0 <br /> m <br /> � o ,t SECOND FLOOR <br /> � / EL. 14'-0" <br /> � OFFICE ' CONFERENCE /� � R&D / ~''�, PRODUCTION ROOM � <br /> 109 � 108 / 110 / �. 121 <br /> � � � � <br /> - �. � 118 .,. . <br /> FIRST FLOOR ► , \ � <br /> �1 <br /> � - - � � - - - - - - <br /> I I�_ ELEVATOR PIT BEYOND <br /> I I . <br /> �Ls _ _ � � . <br /> � <br /> � <br /> �- SECTION A <br />, . SCALE 1/8"=1'-0° A100, A101, A102 r <br /> 0 <br /> I <br /> . �t- <br /> ,� FIRST FLOOR <br /> EL. 0 -0 a a . a . a. <br /> a <br /> � o � <br /> . �.4 D � B 18"x60" RELITES A � a . �', °- <br /> TOP OF PANEL a � �. <br /> EL. 30'-p» . <br /> a ' � a a <br /> .. <br /> � CEILING <br /> - - - - - - - - - - - - - - - - - — — - - - - - - <br /> . 0 0 � 0 0 0 - - - - EL 23'-0°� SECTION C <br /> � - SECOND - SCALE: 1/4"=1'-0" A250 <br /> FLOOR CEILING `� " <br /> � � <br /> SECOND FLOOR <br /> SECOND FLOOR <br /> EL. 14'-0» - - - - - - - - - - - - - - - - <br /> CEILING <br /> - - - - - — — <br /> EL. 9'-0" - - - - - - - - <br /> - - - - - - - - - - - - - - <br /> � FIRST FLOOR <br /> FIRST FLOOR � <br /> � <br /> � <br /> EL. 0 -0 � <br /> OPEN TO <br /> HALLWAY <br /> II � <br /> � � II � // J � <br /> SECTION B -- ii �' � <br /> SCALE: 1/8"=1'-0° A100, A101 <br /> � � � � <br /> 11 TREADS @ 11" = 10'-1" 3'-0" 11 TREADS C� 11" = 10'-1" 10'-1" <br /> . 12" BEYOND RISER STAIRWAY PLAN <br /> SCALE: 1/4" = 1'-0° <br /> PREVENT 4-3/8" SPHERE <br /> (ABOVE 36" TO 42" AFF) ' <br /> . 3» � <br /> � PREVENT 21° . <br /> SPHERE <br /> � ', <br /> � HAND RAIL BRACKET OFFSET 1/4" TOE PLATE HANDRAILS PER 2015 IBC 1014. <br /> TO MAINTAIN 1 1/2" MW 1.5" PIPE HANDRAIL OR EQUIVALENT BOTH SIDES. ' <br /> AROUND HAND RAIL � <br /> � 1-1/2° � SCHEDULE 40 STEEL NORTH SIDE (SHOWN) HANDRAIL ATTACHED TO � <br /> � POSTS, GUARD AND HAND RAILS. WALL WITH BRACKETS COMPLYING WITH IBC 1014. ii <br /> � SOUTH SIDE ATTACHED TO GUARD, ' <br /> N <br /> 3 2015 IBC1015.4 EXCEPTION 3 REFER TO 1/A201 & 2/A201. '� <br /> o HAND RAIL �i � ALLOWS 21" SPHERE CRITERIA W � <br /> N AREAS FOR ACCESS TO AND USE w <br /> � REiURN TO POST �� OF ELECTRICAL, MECHANICAL OR � <br /> � ��/ a���'� PLUMBING SYSTEMS OR <br /> a' �� EQUIPMENT. N �' <br /> �@ �� PREVENT 4" SPHERE o <br /> . � o �� �� (T`(P) i <br /> o i ,.'.>•_�� � � <br /> 0 <br /> � i� ��� n � <br /> � � � <br /> o i� <br /> t` � / <br /> 0 <br /> o � .� � <br /> � I I �� SOLID LANDING w � <br /> � - (WOOD OR STEEL FRAMED) �' . <br /> � <br /> � SOLID SURFACE TREADS N <br /> � AND CLOSED RISERS <br /> . ; 1'-0" <br /> z TREAD DEPTH �" <br /> o �� <br /> � <br /> Q NOSiN� AT STA R AT LAND NG AT EQUIPMENT PLATFORM <br /> U <br /> . O <br /> � <br /> _ u1 <br /> J <br /> � <br /> HANDRAIL EXTENSION 1 TYPICAL HANDRAIL AND GUARD RAIL 2 EQUIPMENT PLATFORM GUARD 3 SECTION D � <br /> : SCALE: 1/2"=1'-0" - SCALE: 1/2"=1'-0" - SCALE: 1/2"=1'-0" - SCALE: 1/4"=1'-0" A100 � <br /> o , <br /> � . _ <br /> J � � . � � � � � ' <br /> � ISSUE FOR APPROVAL <br /> , _ . <br /> _ � <br /> � <br /> U REFERENCE DRAWINGS REVISIONS REVISIONS SCALE: AS NOTED �/� ' <br /> m DRAWING NO TITLE REV DATE BY DESCRIPTION • REV DATE BY DESCRIPTION 62s� � ARCHITECTUR/'"�L I <br /> • �REGIST�RED DRAWN: R. PINLAC <br /> ., AR��, E�T BUILDING SECTION <br /> ENGINEER: R.GHIGLIANO <br /> . � � � � � ; <br /> � <br /> CHECKED: L COSGROVE � <br /> � � � ' �' <br /> - � �, LC-fY .CO�GROVE PROJ MGR: L.COSGROV ' ' ACCESS LASER - TENANT IMPROVEMENT � <br /> Fw' - - _ . _ � . - . , o - - _- , , STATE OF WASHINGTON <br /> ¢ APPROVED:L COSGROVE Our difference PROJECT NO: SHEET NO: REV: <br /> � <br /> � �� is engmeered. /� <br /> �aTE: 10/23/17 www.harrisgroup.com 0070285.�0 A�O� � <br />
The URL can be used to link to this page
Your browser does not support the video tag.