_... ._ _ _ _ _ ____ __ _ ___ ' <br /> ZONE TEMPERATIJRE SENSOR- <br /> MOUNT AT 5'-0" AFF. LOCATE IN <br /> OPPOSITE CORNER OF ROOM FROM <br /> PORTABLE AC UNIT PAC-i. <br /> RTU � <br /> 3 <br /> � AkE E2E1 ('�iDERSMA <br /> A R � H ! T E C T <br /> 5450 E. H�cF� STREET SUITE: 200 <br /> RTU TERMINAL 3'-�" PNOtNIX, ARIZONA 85255 <br /> BOARD 3/4° CONDUIT CONCEALED INSIDE OFFICE WALL 3/4" CONDUIT CONCEALED INSIDE OFFICE WALL P: 480.515.5123 <br /> AND STUBBED UP TO 6" ABOVE BOTTOM CHORD AND STUBBED UP TO 6" ABOVE BOTTOM CHORD WWW.SRA360.coM <br /> OF BAR JOIST IN ROOF STRUCTURE. OF BAR JOIST IN ROOF STRUCTURE. E vt U I P M E N T <br /> SUPPLY SENSOR - BULLET. RAC K Z S <br /> � I GANG BOX MECHANICAL CONTRACTOR TO ZIP-TIE <br /> ELECTRICAL CONTRACTOR TO PROVIDE (I) 18/10 CABLE FROM TO PAC-I UNIT SUPPLY AIR GRILL. <br /> ENTOUCH CONTROLLER TO RTU LENNOX PRODIGY CONTROLS <br /> ENCLOSURE. LEAVE 36" OF EXTR.4 CABLE IN PRODIGY ENCLOSURE <br /> AND 12° OF EXTRA CABLE IN ENTOUCH J-BOX. MECHANICAL <br /> CONTRACTOR TO MAKE FINAL CONNECTIONS <br /> c � DEDICATED DUPLEX RECEPTACLE FOR S S <br /> ELECTRICAL CONTRACTOR TO PROVIDE FLUSH MOUNT ELECTRICAL CONTRACTOR TO PROVIDE FLUSH MOUNT <br /> � SINGLE GANG METAL J-BOX MOUNTED 4" SQUARE METAL J-BOX WITH SINGLE GANG MUDRING PAC-I AND REMOTE SENSOR MODULE PAC- I <br /> � i u VERTICALLY FOR TEMPERATURE SENSOR. HORIZONTALLY FOR ENTOUCH CONTROLLER. (RSM) POWER SUPPLY. <br /> ROOF MOUNT AT 5 -0 AFF <br /> � � MOUNT AT 5'-0" AFF <br /> � � o <br /> � �� Z RSM <br /> � <br /> � TO EMS THERMOSTAT MODULE - ELECTRICAL CONTRACTOR TO PROVIDE (I) 18/2 CABLE ( <br /> � REFER TO FLOOR PLAN AND FROM SENSOR TO ENTOUCH THERMOSTAT CONTROLLER LOCATED <br /> DETAIL #3 FOR CONTINUATION ELECTRICAL CONTRACTOR TO PROVIDE (I) 1812 CABLE 24�� <br /> �� IN CEM OFFICE. ELECTRICAL CONTRACTOR TO LABEL CABLE <br /> AND LEAVE 12" OF EXTRA CABLE COILED UP IN J-BOX. FROM ENTOUCH THERMOSTATE CONTROLLER TO BREAK <br /> MECHANICAL CONTRACTOR TO MAKE FINAL TERMINATIONS. ROOM TEMPERATURE SENSOR. LABEL CABLE <br /> AND LEAVE 12" OF EXTRA CABLE COILED UP IN J-BOX. <br /> SUPPLY DUCT MECHANICAL CONTRACTOR TO MAKE FINAL TERMINATIONS. REMOTE SENSOR MODULE (RSM) SUPPLIED <br /> TERMPERATUR SENSOR BY ENTOUCH ANDINSTALLED BY � <br /> METAL STUD IN OFFICE WALL METAL STUD IN OFFICE WALL � � <br /> ELECTRICAL CONTRACTOR. z�,,� SR. �1�� <br /> REFER TO DETAIL#3 FOR CONTINUATION � M 0���� �f�� <br /> TO ROOFTOP UNIT EMS CONTROLLER- � �~ � � <br /> REFER TO FLOOR PLAN AND DETAIL #3 � � � <br /> FOR CONTINUATION RETURN AIR DUCT MOUNT ' x a �� '' �w � <br /> ASPIRATION BOX AND CO2 SENSOR P �, 4- �, <br /> �� .�bZs ��� <br /> ROOFTOP UNIT TERMINATIONS BREAK ROOM ZONE TEMPERATURE SENSOR CEM OFFICE THERMOSTAT CONTROLLER DATA ROOM ENTOUCH CONTROLS w ��'� ��° <br /> L+ 5 6 7 � <br /> NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE <br /> _� � � <br /> `ci '�;� <br /> ., � ? _ <br /> �. =� —_ <br /> �► � s�- <br /> � ,� F G== <br /> i�►. j =- <br /> � � _ <br /> j:� � <br /> RTU � . _. � __�� <br /> �� <br /> �� � f,�i' O'O ' <br /> P f,r o � <br /> � � a�a "i <br /> � � <br /> t <br /> ��� j <br /> MECHANICAL CONTRACTOR TO INSTALL JUMPER � �I� - �'��� <br /> Z �� tir = 0 <br /> H :: � � �T <br /> �.; � <br /> r ^ <br /> �:- w - - T� <br /> RTU TERMINAL BOARD � �`Ea a.l;= `,�,-� ��b � <br /> � — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � <br /> I � RETURN DUCT <br /> . I I <br /> � 24V 24V � <br /> I S-BUS AC THERMOSTAT AC IAQ SENSOR OUTPUTS SMOKE INPUTS HUMIDISTAT I y = G <br /> � � <br /> I - S + R C G WI W2 YI Y2 OCP � R C A/I �i HUM �i TMP D01 �i D02 DII R C D12 R D13 D14 C I <br /> � � <br /> I � � � � � � � � � � � � � � � � � � � � TO REMOTE ZONE ` FLUSH MOUNT SINGLE GANG J-BOX <br /> I � TEMP. SENSOR ROOFTOP UNIT RETURN AIR DUCT MOUNTED CO2 SENSOR <br /> � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1 <br /> , ELECTRICAL CONTRACTOR TO PROVIDE (I) 18/2 CABLE <br /> FROM ENTOUCH CONTROLLER TO RTU SUPPLY AIR DUCT ELECTRICAL CONTRACTOR TO PROVIDE (I) IS/2 CABLE <br /> SENSOR. ELECTRICAL CONTRACTOR TO COORDINATE FROM ENTOUCH CONTROLLER TO CO2 SENSOR. LEAVE <br /> CABLE PULL WITH MECHANICAL CONTRACTOR INSTALLATION 12" OF EXTRA CABLE COILED UP IN BOTH J-BOXES FOR <br /> OF SENSOR. MECHANICAL CONTRACTOR TO TERMINATE. TERMINATION BY MECHANICAL CONTRACTOR. <br /> RECESSED IN WALL CAVITY <br /> . � <br /> E OS CO ROLLER CO2 SENSOR - RETURN AIR DUCT MOUNTED �•' Q <br /> TH RM TAT NT . <br /> � - - - - - - - - - - � r- - - - - - - - - - - -1 r - - - - - - - - - - - - - - - - - - , � � �j <br /> � Y2 � � I Z I I REMOTE SENSOR MODULE � <br /> � 24V AC � � � STEEL STRUCIURAL COLUMN � <br /> I DC OUT 2 I + I <br /> I Y3 3 I I I ( � � � <br /> � � i-� ELECTRICAL CONTRACTOR TO PROVIDE � � <br /> I I I 8 0-IOV DC I MOUNT IN WEB OF COLUMN IF COLUMN IS I-BEAM <br /> I Y3 RTN 4 � I I ( INPUT I INPUT 2 24V AC � 12" X 12" NON-METALLIC LOCKABLE 3/4" CONDUIT BY ELECTRICAL CONTRACTOR (�j <br /> I I 7 SIG COM I � JUNCTION BOX FOR ELECTRONICS STUB CONDUIT UP 6" ABOVE BOTTOM CHORD TYPE MOUNT PERPENDICULAR TO DIRECTION OF F-- � <br /> I Y 5 I I � ( OF BAR JOIST. TRAFFIC FLOW IN AISLE IF COLUMN IS NOT I-BEAM TYPE � � <br /> � � � <br /> I G 6 I 6 4-20 MA I I I ELECTRICAL CONTRACTOR TO PROVIDE � �/ Q <br /> , . � <br /> I I I � 5 \ a L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J 4" SQUAREMETALJ-BOXWITHSINGLE Q W � <br /> I WZ � I � I � GANG MUDRING MOUNTED HORIZONTALLY U <br /> I DC IN 8 � � 4 � � ELECTRICAL CONTRACTOR TO PROVIDE (I) IS/2 CABLE FOR ROOFTOP UNIT CONTROLLER PROVIDED W W <br /> I I I � 3 ',; �, a � 3/4"CONDUIT FROM ENTOUCH CONTROLLER TO RTU SUPPLY AIR DUCT BY ENTOUCH Q � <br /> I I I I SENSOR. ELECTRICAL CONTRACTOR TO COORDINATE MOUNT AT +84" AFF w � <br /> I C 9 I � Z I CABLE PULL WITH MECHANICAL CONTRACTOR INSTALLATION � � �,� <br /> I W/0/B 10 I I � I I OF SENSOR. MECHANICAL CONTRACTOR TO TERMINATE. ROOFTOP UNIT EMS CONTROLLER O �/ <br /> � O W <br /> i RH ,� � � _ _ _ _ _ _ _ _ _ _ � PROVIDED BY ENTOUCH ~ o <br /> I RC I2 JUMPER w � _ > <br /> � � � _ <br /> o � (� W <br /> � <br /> � <br /> I S2 13 ELECTRICAL CONTRACTOR TO PROVIDE (I) 18/6 CABLE ELECTRICAL CONTRACTOR TO PROVIDE (I) 18/10 CABLE <br /> FROM CO2 SENSOR TO ROOFTOP UNIT CONTROLLER. LEAVE FROM ENTOUCH CONTROLLER TO RTU LENNOX PRODIGY <br /> I S2 RTN 14 I 36" OF EXTRA CABLE COILED UP IN RTU CONTROLLER J-BOX CONTROLS ENCLOSURE. LEAVE 36" OF EXTRA CABLE <br /> AND 12" OF EXTRA CABLE COILED UP IN CO2 SENSOR J-BOX IN PRODIGY ENCLOSURE AND 12" OF EXTRA CABLE IN <br /> I SI 15 � I FOR TERMINATION BY MECHANICAL CONTRACTOR. <br /> ENTOUCH CONTROLLER J-BOX. MECHANICAL CONTRACTOR <br /> ISI RTN 16 � i TO MAKE FINAL TERMINATIONS. <br /> L - - - - - - - - - - -� <br /> � TYPICAL COLUMN MOUNTED RTU CONTROLLER <br /> 00 3 <br /> � NOT TO SCALE Z <br /> r � BULLET SENSOR MOUNTED TO a <br /> I I PAC—I SUPPLY AIR GRILL � DUPLEX RECEPTACLE � <br /> I I SEE POWER PLAN <br /> r <br /> w <br /> � � � <br /> I I POWER SUPF�Y PROVIDED G E N E R A L N 0 T E S . <br /> ( — + I BY ENTOUCH DATE: I/�✓/I� <br /> I ' L CO2 SENSORS PROVIDED BY LENNOX. <br /> I I 2. BREAK ROOM, DA TA ROOM, AND RTU SUPPL Y A/R TEMPERA TURE SENSORS PROV/DED BY I SS U E D F O R: <br /> I I ENTOUCH. ��RM I T S�BM I�TT�aL. <br /> � L — _ _ _ — � 3. ENTOUCH ONE RTU CONTROLLERS PROV/DED BY ENTOUCH. <br /> SUPPLY AIR - DUCT SENSOR <br /> INSTALLED BY MECHANICAL CONTRACTOR 4. REMOTE SENSOR MODULE(RSM)PROVIDED BY ENTOUCH REVISION NO.: DATE: <br /> 5. RSMENCLOSUREPROVIDEDBYELECTR/CAL CONTRACTOR. IQ OWNER REVISION Z-7—IH <br /> 6. ELECTRICAL ROUGH/NAND W/R/NG PROV/DED BYELECTR/CAL CONTRACTOR. SENSOR 2Q OWNER REVISION Z—ZC�—IH <br /> EM S H V A C S C H E M A T I C D A T A R 0 0 M R E M 0 T E S E N S 0 R M 0 D U L E TERM/NA TION PROV/DED BY MECHANICAL CONTRACTOR. Q <br /> � 2 3 <br /> NOT TO SCALE NOT TO SCALE � <br /> JOB NO.: I�—�3� <br /> • SHEET TITLE: �MS DI�hC-7R�M <br /> ,;. . __. D�T'�ILS <br /> �� � ' i <br /> Phone: 602.992.3900 <br /> Fax: 602.992.1541 SHEET NO.: <br /> 809 W.Maryland Aue. <br /> Phoenix,Ai.85013 <br /> Engineering <br /> Associates, �nC �amie@tiglaseng.cam <br /> Cnnsu/tingEngineers TEA#17123 � � � � <br />