<br /> Key Plan:
<br /> �ffi
<br /> .�
<br /> � / �
<br /> ; 34 i ', 3O ; Generai Notes:
<br /> All work to be carried out in accordance with the US International Building Code,Local
<br /> Building Cotles antl Safety Regulations,Water,Electricity regulations and all other
<br /> 4'-2 3/4" 7'-3 1/2" 11'-7" relevant Authorities requirement concemed.
<br /> � � A � i All work to be carried out in a professional&workmanship like manner according to the
<br /> plans&specification.
<br /> Do not scale off the drawings unless otherwise stated and use figured dimensions in
<br /> � Q�- � _ � \� � ( � preference.
<br /> � I � � q ��\\� � , w All dimensions are to be checked&verified on site before the commencement of any
<br /> -� \ N � �\ \ ;" p work,all tlimensions 8 levels are subject to final survey and set-out.
<br /> �A4-' 2�1.2I \� `, � \ \�\�� � , This drawing&design is the property of the design group noted on this sheet and
<br /> ,� _ '�, i M � should not be reprotlucetl either in part or whole without the written consent of this firm.
<br /> 00 ��� \
<br /> _ �. �
<br /> ' � o �
<br /> � � � � \
<br /> $ � � � ', Consultants.
<br /> N � � . , . . ,.._-
<br /> '
<br /> M �V � _ �'� ..,.,ir;. ._. ..'. _..._.'-: ......—;.
<br /> N `�,. „ ...... ...:. �
<br /> � ,, � � �
<br /> , , �, � �,
<br /> � A V `�.
<br /> 8'- 11 1/4" �\� �
<br /> � o � __ A�IGPI � � ___ _ ��., '� i
<br /> o -- �
<br /> � � ��,A � I � I A -' RESTROOM
<br /> �, A OFFIGE 110
<br /> i� � `� ��� � A4-�200.2 j 111 ;
<br /> � �
<br /> .- } ,A4-201,2 °
<br /> �, �� 7 A4-2012; � �
<br /> __.
<br /> _ � �,
<br /> � - _ � ,.
<br /> � �� � d' � , . _
<br /> �
<br /> ��. �` � M i `
<br /> I i (i
<br /> I �
<br /> - �� � � � � � 1 �
<br /> O .. . . . �� � �
<br /> "I ._... � � � `
<br /> T � VESTIBULE
<br /> �_ 5�-��� �� �� �, � �,: �
<br /> � �I' ,� � �v �os
<br /> � � �, �� "� �
<br /> � 4'- �o" 5'-7 ��4�� � C AFETERIA � �` � =�'_ � �
<br /> � �TORAG
<br /> � X � � � 102 `� �\ :;� I 112 �
<br /> w _
<br /> A W r�
<br /> � � �i ��� l ���' �� Y3
<br /> ; � � � �� �� � .,�.;, ,� ,..,�; ��
<br /> �� \ � ,� .�
<br /> � � � K � �� � ��� � �t
<br /> i
<br /> ; �, � �
<br /> � '�� � � � � 10'-61/4" 3'-0" 104B
<br /> I , _
<br /> - �. �
<br /> � , , . ___ _ __ __ _ __-- -- _
<br /> � A4-201.2 � �
<br /> ., .
<br /> �� � A 4, o., � �.
<br /> � ' � � � � V � _
<br /> �'�
<br /> � -
<br /> � , � A4-201.2; 5 �4-2012! � � '
<br /> N � � � 1 � ���
<br /> _ __
<br /> ; � � � �� �
<br /> 1 � i � - �
<br /> \ �� � v �� \' �
<br /> ,i � �
<br /> K �� � .A` �� � � �{,, (�I
<br /> � I �� � _g�� ; IIIIIII�:_�
<br /> � � ; �
<br /> � �
<br /> 2, 6„ � � i
<br /> V�\ �� A o 0
<br /> 4� .��, � A -
<br /> � /� � �
<br /> /
<br /> � � �A4-2002 5 � . � �
<br /> o �;�" 4 �, '
<br /> � `
<br /> � � � _ �
<br /> � ,� . . \\ � N I `,\\,\ �
<br /> � � K �A4-2012j � � ��.� �� �
<br /> I �/ cfl cfl ��� \ �
<br /> � , , � =,, _� KITCHEN
<br /> � ` :a 104
<br /> � N N
<br /> 1 a
<br /> '1 A4- 002
<br /> `' I - \ � -
<br /> � v
<br /> �I v \ M
<br /> y�t � � N
<br /> �
<br /> ' ' N
<br /> O
<br /> � I
<br /> � (A4-201.2� � � i �
<br /> I� � � �� ( .��� ��� � �
<br /> � � �
<br /> i �� , � \\ `�
<br /> � i d
<br /> 1 5'-63/4" 11" 3'-71/2" 11'-4" \`�. �
<br /> �, �, ,�- - _ � � ,
<br /> __ ,, � �
<br /> ,� � , \ �
<br /> � � ,
<br /> �� \ a
<br /> � 113 � � � ;
<br /> ' � ,
<br /> � � � a i
<br /> --r-_ � \ ,,
<br /> �
<br /> � ��. \ �
<br /> �
<br /> ,��► A � �, � � - { � �
<br /> a , � '
<br /> �' � \, v � � �
<br /> � STORAGE �� � ,� 6 ' ,,�
<br /> o �
<br /> 1�3 � ' � �� � � aa-2od2 ��
<br /> � _
<br /> � � M � �LfGf�F __ � 12'- 3" � � °
<br /> A �r-- _ Z _ , �-
<br /> - - -__ - '�
<br /> C M . . . , '. i.,: ` , _ '�
<br /> i� � i �. '� � - /
<br /> e N '
<br /> , ,<,..
<br /> '�__�. ._ ------ ._ ____._____. ___ — F� ._=_� __ __ _.—�- -__ _ � .... — — -- --- ------�` U �i
<br /> 3
<br /> - - � � 4-2D�2� �� � �� ��
<br /> � 11'- 10" � 5'- 1 3/4 ��_ �
<br /> � � 3 ..,--- � A125
<br /> t A4-2012 9 `' �P. Stamp:
<br /> � � � 104 _
<br /> � o , ` 1f��23
<br /> I v ' � � � �;�.� ��+���`�'��i��
<br /> � 103 N_ .�k��H�����°
<br /> ; � ��,;,' ' "
<br /> I �, , o ,� C � �, , 11/�/2016
<br /> , � I�; 4 ��� �
<br /> _ ( � �aarr ��vt��
<br /> � i N �5 ��`F4�'�`3� C�� 'e����Y���a��P�
<br /> ; �.
<br /> `� F ; 7'-0 1/2" 8'- 3 3/4" � � ��
<br /> - �
<br /> co __-- —
<br /> _ _ ------
<br /> � �— _ �
<br /> I SCULLERY �
<br /> 103 `�'
<br /> i <
<br /> �
<br /> �
<br /> ,:';
<br /> , ,
<br /> ;
<br /> ........ 0 -__ � o o [�� �.
<br /> � 103B `
<br /> 11 1/4" 32'- 0" 10'- 7 1/4" A
<br /> ��___ ____ _----- _______
<br /> I F I
<br /> 1 ENLARGED PLAN AT KITCHEN - --
<br /> 1/4�� _ ��-O�� REV DESCRIPTION DATE BY CHK
<br /> _,.;�
<br /> s�� ��' ��
<br /> ENLARGED PLAN - NOTES ENLARGED PLAN - LEGEND
<br /> SHEET NOTES ENLARGED PLANS 701 5th Ave., Suite 6730
<br /> 1.WORK SHALL COMPLY WITH CURRENT FEDERAL,STATE,AND LOCAL BUILDING CODES AND REGULATIONS, 13.TEMPERED GLASS TO BE USED IN LOCATIONS REQUIRED BY CODE. � AREA NOT IN CONTRACT(NIC) � EXISTING PARTITION TO Seattle WA 98104 USA
<br /> TRADE STANDARDS.AND MANUFACTURER'S INSTRUCTIONS REFERENCED IN THE CONTRACT DOCUMENTS. �T REMAIN +1 206 270 7000
<br /> � KEYNOTE TEXT � �-�- � GLAZING WAL� www unispace com
<br /> 14.REVIEW LAYOUTS FOR PARTITIONS W FIELD WITH THE OWNER AND ARCHITECT/DESIGNER PRIOR TO KEY VALUE � � � � ' DENOTES HALF HEIGHT
<br /> 2.EACH BIDDER SHALL VISIT THE SITE AND EXAMINE THE SITE TO ENSURE THEIR KNOWLEDGE OF THE START OF CONSTRUCTION. ����;���
<br /> CONDITIONS AFFECTING THE WORK. j A125 PLUMBER TO SUBMIT FINAL DRAWINGS FOR FLOOR SINKS,WATER SUPPLY AND DRAIN C,4sEwoRK = : .' ._..
<br /> 15.EXISTING FLOORS,EXTERIOR,PARTITIONS, INTERIOR COLUMNS,AND CORRIDOR WALLS TO BE ,
<br /> 3.NOTIFY ARCHITECT/DESIGNER OF CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS BEFORE PATCHED AND REPAIRED AS NEEDED TO MAINTAIN ORIGINAL ACOUSTICAL AND RATED FIRE/SMOKE ' LOCATIONS. Client/Project Name I Address:
<br /> ______ ___ _ __ ___ _ __ NEW PARTITION �, i--� NEW DOUBLE SLIDING
<br /> PROCEEDING WITH CORRECTIVE MEASURES. DESIGN INTENT. PENETRATIONS TO BE SEALED TO MAINTAIN FIRE/SMOKE RATING AND ACOUSTICAL
<br /> RATING. WINDOW OR LOUVER
<br /> �
<br /> 4.VERIFY AND PROTECT SERVICE LINES AND EXISTING SITE AREA FROM DETERIORATION OR DAMAGE. F L U KE CAF E - P HAS E 2
<br /> 16.PATCH AND REPAIR FIRE PROOFING AT BUILDING STRUCTURE,WHERE MISSING OR DAMAGED,TO
<br /> 5 COORDINATE DRAWINGS TO VERIFY DIMENSIONS, DEPRESSED SLABS,SLOPES,DRAINS,OUTLETS, MAINTAIN REQUIRED FIRE RATING. SEE CODE SUMMARY NARRATIVE. '� X� DOOR NUMBER z
<br /> RECESSES. REGLETS. BOLT SETTINGS.SLEEVES, ETC... 6920 Seaway Blvd, Everett,WA 98203 L
<br /> 17.PROVIDE FIRE EXTINGUISHERS(WITH CABINETS)IN QUANTITIES AND LOCATIONS ON DWGS(MIN �
<br /> 6.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL,MECHANICAL, 1/6000 SQ-FT&75'MAX TRAVEL DISTANCE). REVIEW FINAL LOCATIONS WITH THE ARCHITECTlDESIGNER � NFw n��R ��
<br /> ELECTRICAL.SHOP DRAWINGS AND SPECIFICATIONS. PRIOR TO START OF CONSTRUCTION. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS EXISTING DOOR TO REMAIN Px PARTITION TYPE `
<br /> TO ACCOMMODATE FULL CONCEALMENT OF RECESSED CABINETS,UON. SEE SHET.A4-300 FOR N,
<br /> 7. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS. DETAI�S NOTED TYPES AND DETAILS Drawing Title: �
<br /> "TYPICAL"OR"TYP"IMPLY CONDITIONS TREATED SIMILARLY;MODIFY TO ACCOMMODATE MINOR VARIATION. 18.ALIGN CENTERLINES OF FIRE EXTINGUISHER CABINETS AND MEP/FP DEVICES ON WALLS IN THE � FLOOR SINK,NO GRATE.SEE KEY �
<br /> SAME LOCATION.REFER TO SHEET GO-200 FOR DETAILS. NOTE A125 �
<br /> U
<br /> 8.DIMENSIONS: � FLOOR SINK, 1/2 GRATE.SEE KEY °'�
<br /> 19.COORDINATE B�OCKING REQUIREMENTS AND LOCATIONS WITH ELEVATIONS AND DETAILS. NOTE A125 �
<br /> A. DIMENSIONS ARE TO FINISHED FACE OF WALL UON. BLOGKING TO BE FIRE TREATED. E N LARG E D P LAN S '�
<br /> B. DRAWINGS ARE NOT TO BE SCALED;VERIFY MISSING OR CONFLICTING WRITTEN � FLOOR SINK,3/4 GRATE.SEE KEY �
<br /> DIMENSIONS WITH THE ARCHITECTIDESIGNER PRIOR TO CONSTRUCTION. 20.COLUMN ENCLOSURES TO BE PATCHED AND PAINTED UON. PARTITIONS ABUTTING COLUMNS TO NOTE,4125 �
<br /> C. NOTIFY ARCHITECT OF CONDITIONS WHERE CLEAR OR CRITICAL DIMENSIONS ARE ALIGN WITH THE FACE OF THE COLUMN,UON. N
<br /> DESIGNATED BUT CANNOT BE MET OR WHERE CORRIDORlAISLE WIDTH CANNOT MEET �
<br /> THE MINIMUM REQUIREMENTS(3'-8"UON.) 21.PARTITIONS,COLUMN ENCLOSURES,FURRED WALLS,ETC.EXTENDING THROUGH THE CEILING �
<br /> D. MAINTAIN FINISH FLOOR BASE ELEVATION THROUGHOUT THE CONTRACT AREA SUCH MUST BE FULLY CAPPED WITH GWB(OR STUD TRACK)WHEN GWB DOES NOT EXTEND TO DECK ABOVE- WALL TYPE LEG E N D (SEE SH EET A4�3OO.1, Stat�s: p E RM IT S ET �
<br /> THAT DIMENSIONS INDICATED AS ABOVE FINISH FLOOR ARE AT THE SAME CONCEALED AREAS WITHIN WALLS CANNOT BE OPEN TO PLENUM AREAS. �
<br /> ELEVATION. TYPE DETAIL @
<br /> Y
<br /> 22.EXISTING WA�LS TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MEET REQUIREMENTS OF NEW Drawn By: KSR/IH Checked By: DV ``
<br /> 9.MAINTAIN THE PREMISES CLEAN AND FREE OF TRASH, DEBRIS AND PROTECT ADJACENT WORK FROM SURFACES UON. A 1 �
<br /> DAMAGE. SOILING, PAINT OVERSPRAY, ETC. FIXTURES, EQUIPMENT,GLAZING, FLOORS,ETC.SHALL BE LEFT B 2 Sca�e: As indicated �ate: 11/4116 �
<br /> CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF PROJECT. 23.WHERE NEW PARTITIONS ABUTT EXISTING SURFACES,REMOVE EXISTING CORNER BEAD AND C 3 Project Number: WDO��
<br /> PROVIDE SMOOTH FINISH AT INTERSECTION. D 5 a
<br /> 10.MANUFACTURER'S PRINTED WARNINGS FOR HANDLING OF PRODUCTS MUST BE STRICTLY OBSERVED. E 6 0
<br /> 24.PATCH,PRIME AND PAINT WALLS TO REMAIN WHERE WALL RECEPTACLES, FACE PLATES,ETC.ARE F 7 Drawing Number: Revision: �
<br /> 11.WORK TO BE NEW UON. REMOVED. G 9 `°
<br /> H 10 �
<br /> M
<br /> 12.DOORS TO BE A MINIMUM OF 4"FROM NEAREST PERPENDICULAR PARTITION,UON. 25.REFER TO K SHEETS FOR EQUIPMENT DETAILS. J 13 � �
<br /> K 14 � o
<br /> L 15 �
<br /> Z
<br /> M 17 .� a
<br />
|