liiiiiiiiiiiiiH <br /> ABOSSEIN <br /> GENERAL NOTES ENGINEERING ' <br /> 1) COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE MOST CURRENT LANDLORD'S EXISTING GAS ROOFTOP AIR-CONDITIONING SCHEDULE <br /> BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE AND HEALTH CODES AND REGULATIONS AS DESIGNATION: RTU-2 RTU-3 RTU-4 RTU-5 RTU-6 L.L.0 <br /> ADOPTED BY THE LOCAL JURISDICTIONS AND THE STATE OF WASHINGTON. ZONE: ULTA STORE ULTA STORE ULTA STORE MALL CORRIDOR FUTURE TENANT SPACE <br /> 2) ALL AIR-CONDITIONING UNITS WITHOUT INTERNAL TRAP SHALL HAVE A P-TRAP FOR THE MANUFACTURER' LENNOX CARRIER CARRIER LENNOX YORK <br /> CONDENSATE PAN WITH PLUG TEES FOR CLEANING AND CONDENSATE PIPES SHALL BE MODEL' LGC156H2BS2G 48TMD012-A-601HQ 48TMD025-611M LGA036H2BS2G DF102N15D <br /> MECHANICAL-ELECTRICAL <br /> DISCHARGED TO CONDENSATE WASTE PIPING. VERIFY SIZE AND LOCATION AT SITE. DISCHARGE: DOWN DOWN DOWN DOWN DOWN CIVIL-ISD-STRUCTURAL <br /> GAS TYPE: NAT. NAT. NAT. NAT. NAT. LANDLORD'S EXISTING EXHAUST FAN SCHEDULE FIRE PROTECTION <br /> 3) MECHANICAL CONTRACTOR SHALL COORDINATE DIFFUSER LOCATIONS AND DUCT ROUTING NOMINAL TONS OF CLG 13.0 10.0 20.0 3.0 8.0 2100 112TH AVE. NE <br /> CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING, AND LIGHTING PLANS. <br /> COOLING•ARI(MBH): 156 114 238.0 35.8 99.0 DESIGNATION: EF-1 EF-2BELLEVUE, WA 98004 <br /> 4) PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING VENT STACKS WITH THE EQUIPMENT TO12.2 10.1 s.25 (12.0) 10,4 ZONE: SALON EXISTING TO REMAIN <br /> E.E.R.(SEER). <br /> MAINTAIN A MINIMUM OF 12 FT. FROM THE OUTSIDE AIR INTAKES. MANUF.: CAPTIVEAIRE CAPTIVEAIRE OFFICE: (425)462-9441 <br /> IPLV 13.6 11.0 --- --- --- FAX: (425)462-9451 <br /> 5) ALL FIRE RATED STRUCTURE SHALL BE FIRE DAMPERED. VERIFY WITH THE ARCHITECTURAL MODEL: NCA14FA NCA14FA <br /> AND INSTALL PER THE LOCAL JURISDICTIONS. HEATING INPUT(MBH): 260 120 275 78 180 TYPE: UPBLAST UPBLAST EMAIL: <br /> NG OUTPUT <br /> 6) PROVIDE WSEC COMPLIANT WALL MOUNTED PROGRAMMABLE THERMOSTATS WHERE INDICATED. HE'°'n (MBH)` 208 s6 223 62 108 DRIVE: BELT BELT CService®abossein.com <br /> AFUE(STEADYY S STATE) (78%) (78%) (78%) (78%) (78%) <br /> 7) ALL VOLUME DAMPERS IN NON-ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED FAN MOTOR DRIVE: <br /> BELT BELT BELT BELT BELT CFM: 2300 2300 WEBSITE: <br /> TO AN ACCESSIBLE LOCATION ("YOUNG" REGULATORS (WITH BOWDEN CABLE SYSTEM), OR CFM: 5100 4000 8000 1200 3200 E.S.P. (IN-H20): .60" .60" www.abossein.com <br /> EQUAL). EXACT LOCATION OF CONTROL DEVICES VISIBLE IN FINISHED SPACES SHALL BE E•S,P,( 20): 1.5" 1.0" 1.0" .60" .60" SONES: -- -- <br /> COORDINATED WITH THE ARCHITECT. 5.0 3.0 7.5 1.5 3.0 HP iFLA): 1 HP 1 HP <br /> INDOOR FAN(HP): VOLTAGE: 460 460 <br /> 8) ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH-ROUND OR SQUARE WITH TURNING OUTDOOR FAN(FLA): 4© 1.3 2 0 .70 2 ©3.3 1.3 2 © .80 ` <br /> VANES. RIA/LFA:PRESSOR A/LFA' 3 © 7.1/50 2©7.9/64 19.2/125 17.3/114 5.8/39 2 © 6.5/42 PHASE: 3 3 <br /> 9) MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF PIPING AND WEIGHT:COMB.FAN(FLA)' -- -- .30 -- -- •1/4?, ---!-` <br /> DUCTWORK AND PENETRATIONS WITH THE STRUCTURE. 39/45 22.6/25 61/80 12/15 21.3/25 REMARKS: c� <br /> 10 MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 6' OR AS SHOWN ON DRAWINGS. MCA/MOCP "�, �, <br /> VOLTAGE 460 460 460 460 460 `` '' <br /> 1 1 ALL DUCTWORK, EQUIPMENT AND PIPING SHALL BE SEISMICALLY SUPPORTED PER SMACNA '"�;. <br /> AND LOCAL REGULATIONS. PHASE: 3 3 3 3 3 ' f <br /> 1 2) ALL AIR FILTERS SHALL HAVE EFFICIENCY BASED ON THE ASHRAE STANDARD 52-76 WEIGHT(LBS). - '', :891. <br /> (ATMOSPHERIC DUST SPOT). '\'\`.' , t. <br /> 13) ALL MECHANICAL EQUIPMENT SHALL CONFORM TO SMACNA AND LOCAL REGULATIONS FOR STATUS: EXISTING TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN EXISTING TO REMAIN <br /> SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). <br /> 14) ALL EQUIPMENT AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE <br /> a�wuommr matAsurr�urwormaon <br /> ACCESS DOORS. <br /> 15) TOTAL SYSTEM SHALL BE WARRANTED FOR ONE YEAR; STARTING FROM THE TIME OF OWNER/ o <br /> ENGINEER'S FINAL ACCEPTANCE. c, <br /> 16) HVAC NOTES: an <br /> A) PROVIDE FLEXIBLE CONNECTION IN ALL DUCTS CONNECTING TO AIR MOVING EQUIPMENT HIGH EFFICIENCY GAS ROOFTOP AIR-CONDITIONING SCHEDULE <br /> AS CLOSE TO FAN AS POSSIBLE. FLEXIBLE CONNECTION SHALL CONSIST OF 6" OR DESIGNATION' RTU-1 P.T4 V; <br /> MORE OF AIR TIGHT, FIREPROOF FLEXIBLE NEOPRENE COATED WOVEN FIBROUS GLASS ZONE: ULTA RETAIL SPACE <br /> Minimum Outside Air Ventilation Schedule <br /> MATERIAL. VENT FABRICS, INC., OR APPROVED EQUAL. MANUFACTURER LENNOX - LGH EMERGENCE SERIES ix <br /> MODEL: LGH-156-H4B Ventilation Rate per 2009 IMC 403(based on ASHRAE Std.62.1-2007) PO g <br /> B) ALL DUCTWORK SHALL BE SHEET METAL. SOUND LINE RECTANGULAR SUPPLY AND <br /> DISCHARGE: DOWN Zone Breathing Zone Air System Proposesd CD <br /> RETURN DUCTS WITHIN 15 FEET FROM THE UNIT OPENINGS. GAS TYPE: NAT. People Outdoor Population. Area Outdoor Zone Distribution Zone Ventilation Minimum Design <br /> C) ALL SUPPLY AND RETURN FLEXIBLE DUCTS SHALL BE CONSTRUCTED OF DOUBLE NOMINAL TON OF CLG 13.0 Air Rate Number of Air Rate Occupant Outdoor Air Effectiveness Outdoor Air EfficiencyEv outdoor Air Outdoor Air <br /> LAMINATION OF POLYESTER ENCAPSULATED STEEL WIRE HELIX FOR INNER CORE HIGH COOLING•AR(MBH): 152.0 Occupancy (cfm/person) people in (cfm/sf) Density Flow Ez(Table Flow (Table Intake Flow Intake Flow <br /> DENSITY FIBERGLASS INSULATION AND GRAY POLYESTER FILM WITH SPIRAL HEATING INPUT(MBH)' 260 Equip,Tag Zone Category Area(sf)Table 403.3 space.* (Table 4033) (#/1000sf) Vbz/(CFM) 403.3.1.2) (Voz/(CFM) 403.3,2.3.2 Vot/(CFM) Vot/(CFM) W <br /> REINFORCEMENTS EQUAL TO "ATCO-70 SERIES" (MIN. POS. PRESS. = 6" W.G., NEG. HEATING OUTPUT(MBH). 208 RTU-1,2,3,4 ULTA Retail Retail 10727 7.5 80 0.12 15 1887.24 1.00 1887.24 0.90 1699 1700 1 1-.! <br /> PRESS = 0.75" W.C.). LEER: 13.6 ^w � <br /> yy <br /> D) PROVIDE LOCKABLE QUADRANT VOLUME DAMPERS IN ALL AIR DISTRIBUTION OUTLETS. AFUE:(STEADY STATE) (80%) RTU-5 Future Retail Retail 1390 7.5 20 0.12 15 316.80 1.00 316.80 0.90 285 300 ✓64 W <br /> E) DUCT HANGERS, SUPPORTS AND METHODS OF INSTALLATION SHALL CONFORM TO FAN MOTOR DRIVE: BELT RTU-6 Hall Corridors 537 NA NA 0.06 NA NA NA NA NA 32 100 <br /> : 5000 TOTAL 2016 2100 U) Fa <br /> ASHRAE AND SMACNA RECOMMENDATIONS. E.S.P.(IN-H20): 1.0" *In some cases occupancy is less than maximums as allowed per403.3 exception,in no case shall the occupancy be less than one half per Table 403.3. <br /> F) DUCT SIZES SHOWN ON PLANS INDICATE INSIDE FREE AREA. OUTSIDE AIR(CFM) --- <br /> INDOOR FAN(HP/FLA)' 3.0 HP/ 10.6 <br /> G) ALL DUCTWORK SHALL BE CLASS 1 AIR DUCT AS APPROVED BY U.L.-181. OUTDOOR FAN(FLA); 3 © 1.3 <br /> M (3) ©7.1/46.0LRA <br /> H) DUCTS: SHEET METAL DUCTS SHALL BE INSULATED WITH THE INSULATION AND COMPRESSOR RLA/ <br /> THICKNESSES AS SHOWN HEREIN (REDUCE THE INSULATION THICKNESS BY THERMAL COMB.FAN(FLA): _ <br /> 35 40 Z <br /> VALUE OF SOUND LINING). MCA/MOCP 460 <br /> � <br /> VOLTAGE. <br /> 1. SUPPLY AIR DUCTS IN HEATED SPACE (ABOVE CEILING) SHALL BE INSULATED TO A PHASE' 3 <4 E <br /> MINIMUM R-VALUE OF R-4.2. EXPOSED DUCTWORK SHALL NOT BE INSULATED. WEIGHT(LBS): 2270 E-4 4 <br /> 2. SUPPLY AIR DUCTS IN UNHEATED SPACE SHALL BE INSULATED TO A MINIMUM REMARKS (1) <br /> NOTES: <br /> R-VALUE OF R-8. <br /> (1)R410A REFRIGERANT,24"HIGH ROOF CURB,FACTORY PROVIDED DIFFERENTIAL ENTHALPY OUTSIDE AIR ECONOMIZER.,FACTORY PROVIDED POWER EXHAUST FAN.,HIGH STATIC DRIVE KIT,BACNET MODULE WITH w <br /> 3. SUPPLY AIR DUCTS OUTSIDE OF BUILDING SAME AS NON-HEATED SPACE EXCEPT REMOTE SENSOR.,LOUVERED CONDENSER COIL HAIL GUARDS.,FACTORY WIRED AND FACTORY INSTALLED NON-FUSED DISCONNECT.FACTORY INSTALLED UNPOWERED GFI WEATHERPROOF CONVENIENCE OUTLET. E A <br /> DUCT SMOKE DETECTORS(IN RETURN),FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR.SMOKE DETECTOR TO BE MOUNTED IN SUPPLY&RETURN AIR DUCT OR <br /> WITH WEATHERPROOF BARRIER. INSULATION SHALL MEET ALL CRITERIA AS PRESCRIBED AS REQUIRED BY LOCAL CODE.FACTORY START-UP EACH UNIT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> IN THE WSEC. INCLUDE WEATHER HOOD,2"PLEATED FILTERS,CRANKCASE HEATER,HIGH AND LOW PRESSURE SWITCHES. W <br /> LENNOX NATIONAL ACCOUNTS CUSTOMER SERVICE:ULTA SALON.COSMETICS&FRAGRANCE.INC. <br /> 4. RETURN AIR DUCTS; SHALL HAVE SAME INSULATION AS THE SUPPLY AIR DUCTS. FOR QUOTATIONS AND ORDERS CONTACT:JOSH PLUMMER,NATIONAL ACCOUNT SALES ASSISTANT,PHONE 800-367-6285 OPTION 1 EXT 6784,FAX 972-497-5112,EMAIL JOSHUA.PLUMMEROLENNOXIND.COM ��" w <br /> INSULATION SHALL MEET ALL CRITERIA AS PRESCRIBED IN THE IMC. FOR EQUIPMENT WITH FACTORY INSTALLED ACCESSORIES PLEASE ALLOW 6-8 WEEKS LEAD TIME. a <br /> REQUIRED. FOR TECHNICAL SUPPORT CONTACT:NATIONAL ACCOUNT TECHNICIAN CONSULTANT,PHONE 800-367-6285 OPTION 2(HOLD FOR NEXT AVAILABLE CONSULTANT),FAX 800-453-7290 g <br /> 5. EXHAUST AIR DUCTS; NO INSULATION <br /> FOR PARTS ORDER CONTACT:COMMERCIAL PARTS CUSTOMER SERVICE,PHONE 800-453-6669,FOR IN-WARRANTY PARTS PROCEDURES CONTACT:EMAIL INDWARRANTY@LENNOXIND.COMcn <br /> 0 <br /> FOR CREDIT/BILLING ISSUES CONTACT:JIM HANSEN,CUSTOMER FINANCIAL SERVICES ADMINISTRATOR,PHONE 972-497-6046,FAX 972-497-6151,EMAIL JIM.HANSEN@LENNOXINTL.COM ,-. <br /> LEGEND <br /> 17) THE CONTRACTOR SHALL NOT OPERATE THE EQUIPMENT FOR TEMPORARY HEATING OR FOR GENERAL ACCOUNT NEEDS IF ABOVE MEMBERS CAN'T ASSIST YOU,CONTACT:KATIE SCHMITTER,NATIONAL ACCOUNT MANAGER,PHONE 773-852-2175,EMAIL KATIE.SCHMITTER®LENNOXIND.COM <br /> VENTILATION DURING THE CONSTRUCTION. (ALL EQUIPMENT SHALL RUN FOR TESTING AND SYMBOL ABBREVIATION DESCRIPTION '771, --- <br /> BALANCING PURPOSES ONLY). NOTIFY THE ENGINEER 48 HOURS (MINIMUM) IN ADVANCE ®/® T'STAT/SENSOR THERMOSTAT/SENSOR ..i ' - - -~-=.. <br /> TO ARRANGE A FINAL FIELD INSPECTION PRIOR TO COVERING UP THE CEILING. ,-,.11 __ DUCTWORK W/TURNING <br /> VANE AND FLEX CONN. <br /> 18) CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY -� VD VOLUME DAMPER <br /> CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND -- RIGID DUCT <br /> INSTRUCTIONS TO BIDDERS -- FLEXIBLE DUCTrzz <br /> AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING <br /> THE CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE 1. VERIFY WITH OWNER AND GENERAL CONTRACTOR FOR OWNER 03 -- ROUND SPIN-IN WITH V.D. <br /> OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH FURNISHED ITEMS PRIOR TO BIDDING/CONSTRUCTION. FD FIRE DAMPER <br /> DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER SFD SMOKE FIRE DAMPER <br /> 2.DESIGN DRAWINGS ARE SCHEMATIC.THIS CONTRACTOR SHALL VISIT THE <br /> LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING • CFD CEILING RADIATION FIRE DAMPER r4, C/) <br /> ARCHITECT/ENGINEER'S APPROVAL. FIELD CONDITIONS.THIS CONTRACTOR SHALL INCLUDE ALL LABOR AND QO CD ROUND CEILING DIFFUSER 1.-`4 <br /> r,1 <br /> MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING F CG ROUND CEILING GRILLE 0.4 <br /> 19) ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM DEFECTS IN CONDITIONS. CD SQUARE CEILING DIFFUSER �--� <br /> MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED 3.THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER CG SQUARE CEILING GRILLE <br /> HEREIN. IF IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE -CD- CD CONDENSATE DRAIN LINE <br /> DESIGN AND INCLUDE 1N HIS BID ALL COSTS TO MEET THE DESIGN <br /> DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECTINTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER ® -- SMOKE DUCT DETECTOR W <br /> ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT A.F.F. ABOVE FINISHED FLOOR { �•�{ <br /> AT HIS EXPENSE. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF OTHER CONTRACTOR'S COST. }.y.q <br /> WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY. NO WARRANTY OF MERCHANT 4.BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL 0 <br /> ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. (THE WARRANTY SHALL START FROM THE CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS <br /> TIME OF ARCHITECT/ENGINEER'S FINAL ACCEPTANCE.) FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING ENERGY CODE NOTES <br /> CODES,THE PLANS AND SPECIFICATIONS NOT WITHSTANDING.THE <br /> 20) ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY 1) THERMOSTATS SHALL BE A 7 DAY PROGRAMMABLE TYPE ^ <br /> ACCESSORIES SHALL BE PER BASIC OWNERS' STANDARDS. MECHANICAL CONTRACTOR APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN WITH A 5 DEGREE DEADBAND AND AUTOMATIC SETBACK I�1 <br /> INTENT. CONTROL PER 1412.2 WA STATE ENERGY CODE. <br /> IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. <br /> 5.VERIFY WITH THE GENERAL CONTRACTOR FOR FIRE ALARM (SMOKE/FIRE 2) HVAC EQUIPMENT SHALL MEET THE MINIMUM ENERGY <br /> 21) MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION DAMPERS, ETC.) PRIOR TO BIDDING. EFFICIENCY RATINGS PER TABLE 14-1, 14-2 AND 14-3 <br /> FEASIBILITY OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND OF THE WA STATE ENERGY CODE. <br /> 6.CONTRACTOR SHALL INCLUDE IN BID THAT EACH HVAC UNIT SHALL BE EQUIPPED 3 DUCT INSULATION AND SEALING SHALL MEET CHAPTER 14 <br /> INCLUDE IN HIS BID ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT WITH ENTHALPY ECONOMIZER, MPC (MILT-PROTOCOL CONTROL) COMMUNICATION ) <br /> SYSTEM READY FOR OWNER'S BENEFICIAL USE. CARD-BACNET, SECTION 1414 REQUIREMENTS. UNITS BETWEEN .50"S.P. TO <br /> BE REQUIRED FOR A COMPLETE S M POWER EXHAUSTER, SMOKE DUCT DETECTOR IN RETURN, <br /> 22) COORDINATE THE CONSTRUCTION SCHEDULE WITH THE OWNER AND PERFORM ALL REQUIRED GFI 115V POWER OUTLET FOR SERVICE AND MAINTENANCE. 2" S.P.-SEAL TRANSVERSE JOINTS WITH AN APPROVED <br /> MASTIC OR EQUAL. <br /> WORK IN STRICT ACCORDANCE WITH THE OWNER'S SCHEDULE. 7.THE CONTRACTOR SHALL INCLUDE COSTS FOR MODIFYING THE EXISTING 4) SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES <br /> GAS PIPING SYSTEM TO ONLY SERVE THE HVAC SYSTEMS FOR THESE SPACES <br /> SHALL BE INSULATED TO MIN. R-7. ROOFTOP HVAC <br /> 23) MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND FOR TENANT BILLING PURPOSES.A GAS PIPING PLAN WILL BE PROVIDED FOR <br /> GAS PIPING MODIFICATION AS REQUIRED FOR COMPLETE AND FUNCTIONING <br /> DUCTWORK SHALL HAVE A WEATHER BARRIER. Revisions: Date: <br /> CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 5) SUPPLY AND RETURN DUCTS IN CONDITIONED SPACES <br /> GAS PIPING SYSTEM. IT IS INTENDED THAT THE EXISTING GAS METER THAT SHALL BE INSULATED TO MIN. R-4. PERMIT SET 8/3/12 <br /> 24) ADJUST ALL EQUIPMENT AND PERFORM A COMPLETE AIR-BALANCING AND PUT ALL MECHANICAL SERVES THESE SPACE SHALL BE REUSED. REPLACE GAS METER IF NEW GAS <br /> SYSTEMS IN OPERATION AND SUBMIT MINIMUM 4 COPIES OF BALANCING REPORTS TO THE LOAD IS BEYOND CAPACITY OF EXISTING GAS METER OR INSTALL NEW METER 6) PIPING INSULATION SHALL MEET THE REQUIREMENTS <br /> OWNER. IF ONE IS NOT PRESENT FOR EACH TENANT SPACE. GAS PIPING DISCONNECTED OF WA STATE ENERGY CODE TABLE 14-6. <br /> PLAN g�� ��D��/: <br /> i , <br /> FROM THE 4"MAIN SERVING PARTY CITY SHALL BE CAPPED AND SEALED. 7) OUTSIDE AIR DUCTS SHALL BE INSULATED PER WA STATE /rli V /� Q <br /> 25) ALL NEW PENETRATIONS OR ABANDONED PENETRATIONS SHALL BE MADE WATERTIGHT. DISPOSE 8.THE CONTRACTOR SHALL COORDINATE AND SCHEDULE A FACTORY START UP FOR ENERGY CODE SECTION 1414.2. OUTSIDE AIR DUCTS M1.0 GENERAL NOTES, SCHEDULES, AND PLAN INDEX <br /> OF AND REMOVE ALL ABANDONED AND/OR EXISTING DUCTWORK, DIFFUSERS, GRILLES, ETC. IN EACH HVAC UNIT COMPLETED BY THE HVAC UNIT MANUFACTURER'S REPRESENTATIVE SHALL HAVE A MOTORIZED DAMPERS OR AUTOMATIC DAMPER - <br /> AN APPROPRIATE MANNER. COORDINATE MECHANICAL DEMOLITION WORK WITH OWNER PRIOR PRIOR TO THE DATE OF OF THE LANDLORD TURNOVER. STARTUP SHALL INCLUDE FOR ALL OUTSIDE AIR INTAKES, EXHAUST AND RELIEF OUTLETS M2.0 ROOF PLAN - HVAC <br /> TO BIDDING/CONSTRUCTION. A REPORT INDICATING UNITS ARE OPERATING PROPERLY AND THE MPC CARDS THAT ARE NOT IN CONTINUOUS USE PER 1412.4.1. <br /> ARE CONFIGURED AND PROGRAMMED BY THE UNIT MANUFACTURER. M3.0 SPECIFICATIONS <br /> Job No.:212080 <br /> Date: <br /> M1 .O <br /> (1 OF 3) <br /> 1402 SE Everett Mall Way, 81208-010 <br />