My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2019 10:22:24 AM
Creation date
10/25/2019 10:03:21 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T 206.52Seattle,Washington <br /> 1 i = , , www.p2cla2.951nd.com0 <br /> TURNING VISIONS INTO REALITY <br /> F. Conveyance Analysis <br /> As required by Volume I, Chapter 3.2.6.G. of the Manual an analysis of the proposed <br /> conveyance system pipes has been performed. Per Volume I, Chapter 5 of the Manual the <br /> Rational Method was used to determine design flows. See Appendix B — Conveyance <br /> rCalculations for more information and the results of the calculations. <br /> On-site stormwater conveyance has been calculated through gravity flow analysis of the <br /> piping network. Based on a 25-year storm event, peak runoff was routed through the <br /> system and determined to be adequate. Uniform Flow Analysis utilizing Manning's <br /> equation was employed with a Manning's "n" value of 0.012. <br /> ii Q_ 1.49xAxR7xS12 <br /> Manning's Equation: n <br /> With: Q = Flow (cfs) <br /> n = Manning's Roughness Coefficient (0.012) <br /> IA = Flow Area (sf) <br /> R = Hydraulic Radius = Area/Wetted Perimeter (If) <br /> S = Slope of the pipe (ft/ft) <br /> Calculation of an example onsite stormwater pipe: <br /> Q = Flow (cfs) — to be determined <br /> n = 0.012 <br /> _ A = 0.7707/(12"/12) = 0.7707 SF (Appendix 16.A.Civil Engineering Reference Manual) <br /> R = 0.2864/ (12"/12) = 0.2864 LF (Appendix 16.A.Civil Engineering Reference Manual) <br /> S = 0.005 <br /> Q= 1.49/0.012 * 0.7707 * 0.2864(2'3) * 0.005(1/2> = 2.94 CFS <br /> Additional information regarding the conveyance calculations summary can be found in <br /> Appendix B. <br /> '1 Large Storm Event/Overflow Condition <br /> The proposed stormwater conveyance system for this project has been designed to address <br /> I storm events in accordance with the design criteria described above. During events larger <br /> than the design criteria or as a result of clogged/blocked pipes there may be overflows <br /> within the system. The low rim elevation in the system is the catch basin at the southwest <br /> corner of the parking lot. In the event the 21" outlet pipe from the flow control structure is <br /> blocked, stormwater would overtop this catch basin and flow onto the neighboring <br /> properties to the south and west. <br /> —Everett Mall Plaza Parcel III Retail Expansion Stormwater Site Plan Page 24 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.