Laserfiche WebLink
. i <br /> Permit#: E1809-040 <br /> t Site Address: 3003 W CASINO RD 45-03 <br /> EVERETT FIRE PANEL REPLAOEM Owner: BOEING COMPANY <br /> Tenant: [TenNamej <br /> App.Date: 9/7/2018 <br /> Proposed Use: MFG <br /> BOEING COMM E R IAL AIRPLANE GROI REPLACE FIRE ALARM SYSTEM,CONTROL <br /> PANEL,DEVICES <br /> Re '- -• : • Date: <br /> BUILDING 45-00,3 rOffice Se' Job Site Set Fire/Planning Set <br /> Et tabid 11140441161° <br /> EVERETT FACILITY e 1 w01 \,311 <br /> 3003 WEST CASINO ROAD NEPA 72 u ,... \ <br /> EVERETT WASHINGTON 98203 PRETEST PAPERwoRx ,\ <br /> FOR AT, F�REQUIRED <br /> VICINITY MAP SITE PLAN CODE SUMMARY PROJECT DESIEAM <br /> *EXISTING BOEING - THE FOLLOWING CODE INFORMATION IS SUBMITTED FOR REFERENCE ONLY.THE BUILDING IS OWNFR• BOEING COMERCIAL AIRPLANE GROUP <br /> FACILITIES 3003 WEST CASINO ROAD -NOT BEING MODIFIED EXCEPT AS NOTED BY SCOPE.SEE SCOPE OF WORK BELOW EVERETT,WASHINGTON 98203 EVERETT <br /> AA <br /> •. \ PROJECT MANAGER:MATT KENT E ETT Fi y {, +�0 a <br /> TET:425.299.4719 l�e�a (�1� <br /> S .;,:..:'.(.: <br /> .•.:.•. I <br /> •:•• {. - BUILDING CODE: 2003 IBC SNOHOMISH COUNTY PROJECT MANAGEMENT: SAZAN GROUP 2930 pq <br /> 4\y oV �e EVERETT _ JU OCCUPANCY GROUP: 51 600 SIEWART STREET,SUITE 1400 WA wL I'� <br /> • `�' ( CONSTRUCTION TYPE: II-F.R.AND II-N SEATTLE,WASHINGTON 98101 Everett, ••'- <br /> $ o TEL 206.576.7289 <br /> \\ LOCATION ON PROPERTY: SEPARATION 60 FEET(MINIMUM ALL SIDES) FAX:206.267.1701 <br /> • t+ c \�J CONTACT:CARRIE KRAUSE <br /> •S e6,..,'7 40-0I 40-51 FLOOR AREA(ACTUAL): 70,996 SF <br /> BUILDING HEIGHT: 113 FT EMNL CKRAUSE®SA7AN.COMly <br /> ��''--- <br /> • <br /> SEA - ,�``))ELLEWE �� Q r N 6 ' \ J.__.� �_.� —, STORIES: 1 �" b <br /> r <br /> �^'/� 1 U • ". I o x_29 FIRE PROTECTION FULLY AUTOMATIC THROUGHOUT FIRE ' ,..._ Ls' <br /> �J•ENTON y`i , SR 526 N i SUPPRESSION CLASS I• WF <br /> /rnl\ /^\\\\ � <br /> SEPARATION: :'i 2 HOUR BETWEEN EACH OCCUPANCY GROUP SEP 17 0g <br /> '-I /J xK g' r ` 145------E -4--n,.5-5,9 EXTERIOR WALL(NON-BLARING): NON-COMBUSTIBLE• �$y <br /> (((J ITU// 'UBURN ,' lir <br /> INTERIOR WALLS(NON-BEARING): NON=COMBUSTIBLE•• <br /> 0 5 10 • / . _ INTERIOR WALLS(BEARING): NON-COMBUSTIBLE <br /> _ <br /> MILES • \' o� STRUCTURAL FRAME: NON-COMBUSTIBLE INDEX OF DRAWINGS CITY O ff' RETT <br /> I <br /> TACOMA q'(� <br /> ^Li y r(5.--- FLOORSURAL G NON-COMBUSTIBLE ���j' )�CEK <br /> ices <br /> • <br /> � eQ�! Iq STARS ENCLOSURES: N/A(EXISTING) INLSET <br /> •=1 <br /> /// DRAWING NO. SHEET NO. DRAWING TIRE REV DATE <br /> ��. )� SHAFT ENCLOSURES: N/A(EXISTING) <br /> • ...yUK)�-0.�,'..�..', :cam �. �JG�'' LMI° AREA OF ELEVATOR SHAFT: N/A(EXISTING) <br /> • ELECTRICAL <br /> $o ��,' �T�� "I 45-02 /' - WORK CORRIDORS: N/A(EXISTING) • 45-003-GO GO COVER SHEET - 0.27.17 <br /> ->''' o _ ROOF CONSTRUCTION: FIRE RETARDENT:CLASS A••• • 45-003-EI El ELECTRICAL ABBREVIATIONS AND LEGEND A 0.27.17 <br /> SEISMIC: ZONE 3 • 45-003-1E264R I E264R FIRE ALARM SYSTEM-FIRST FLOOR-REMDVA. A 0.27.17 <br /> W <br /> DESIGN LOADS: SEE STRUCTURAL DRAWING 45-003-52 • 4503-E506R E506R FIRE ALARA DETAILS-REMOVAL _ 0.27.17 <br />• ijREn WSNREC: N A • 45-003-E506-2R E506-2R ENLARGED FOAM ROOM PLAN-REMOVAL 0.27.17 <br /> ACILITI' / • 45-003-E506-3R E506-3R FIRE ALARM DETAILS-HUNGER SUPPRESSION-ARSENAL - 0.27.17 <br /> SR 5�6 SN�O'NASA/ • Q ' \ • 45-003-E506-6R E506-6R FIRE ALAN DETAILS-HARDER SUPPRESSION-RDOYAL - 0.27.17 <br /> R/l• <br /> •NORTH/SOUTH OF STORAGE:2 HOUR(OCCUPANCY SEPARATOR) <br /> ` • CASINO ROAD 1 , • 45-003-1E260 IE260 FIRE ALARM SYSTEM-FIRST FLOOR A 0.27.17 <br /> \yI j /� •• •WEST OF STORAGE:2 HOUR(OCCUPANCY SEPARATION) <br /> 1 I/\_SITE • • 45-003-IE262 1E261 FIRE ALARM SYSTEM-FIRST FLOOR A 0.27.17 <br /> egOpO,Wp'l ••STORAGE:2 HOUR(OCCUPANCY SEPARATION) • 45-003-IE262 IE262 FIRE ALARM SYSTEM-FIRST FLOOR A 0.27.17 <br /> cep • 45-003-1E264 1E264 FIRE ALARM SYSTEM-FIRST FLOOR A 0.27.17 <br /> 1 • 45-003-1E265 1E265 FIRE ALARM SYSTEM-FIRST FLOOR A 0.27.17 <br /> 1 SCOPE OF WORK • 45-003-CWE260 CWE260 FIRE ALARM SYSTEM-CATWALK A 0.27.17 <br /> j�PAINE <br /> . SCOPE <br /> • 45-003-E506 E506 - FIRE ALARM SYSTEM DETAILS - 0.27.17 <br /> a FIELD SILVER LAKE <br /> -�� -� SCOPE OF WORK: THE SCOPE OF THIS PROJECT IS TO UPGRADE THE EXISTING BUILDING FIRE ALARM SYSTEM. • 45-003-E506-1 E506-1 FIRE ALARM SYSTEM DETAILS 0.27.17 <br /> Et <br /> ELECTRICAL: THE WORK TO BE PERFORMED INCLUDES,BUT IS NOT LINKED TO THE FOLLOWING: • 45-003-E506-2 E506-2 ENLARGED FOAM ROOM PLAN 0.27.17 <br /> 1REMOVE EXISTING ZINCYCO FOCUS EQUIPMENT. • 45-003-E506-3 E506-3 FIRE ALARM DETAILS-HANGER SUPPRESSION 0.27.17 <br /> d.'o' ., ADT • 45-003-E506-4 E506-4 FIRE ALARM DETAILS-HANGER SUPPRESSION - 0.27.17 <br /> • a *� 2. PROVIDE SIEMENS XLS BUILDING FACP(RRE ALARM CONTROL PANEL)IN PLACE OF REMOVED ADT • 45-003-E506-5 E506-5 FIRE ALARM DETAILS-HANGER SUPPRESSION - 0.27.17 <br /> .\('-' 0E1_1_72400' O 3. PROVIDE FATC(FIRE ALARM TERMINAL CABINET)NEXT TO NEW BUILDING RCP FOR HOUSING • 45-003-E506-6 E506-6 FIRE ALARM DETAILS-HANGER SUPPRESSION - 0.27.17 <br /> MONITORING/INPUT MODULES. • 45-003-E506-7 E506-7 FIRE ALARM DETAILS-HANGER SUPPRESSION 0.27.17 <br /> �� , /)�\\\ 1-1 <br /> 0 500 4. CONNECT ALL MONITORING POINTS FORMERLY CONNECTED TO ADT/TYCO EQUIPMENT TO THE SIEMENS <br /> 0 // <br /> (2) <br /> S BUILDING FIRE ALARM CONTROL PANEL ROUTE THROUGH FATC. <br /> / 5. DISCONNECT AND REMOVE SIEMENS MXL FIRECP. CANNON FACP.PROVIDE SIEMENS XLS FIRE CANNON <br /> FACP IN PLACE OF MXL ERE CANNON FACP. <br /> 6. CONNECT ALL CIRCURS(POWER,INMATING,NOTIFICATION AND AUMUARY)FORMERLY CONNECTED TO <br /> SIEMENS MXL FIRE CANNON FACP TO THE NEW FIRE CANNON FACP. <br /> 7. DISCONNECT AND REMOVE EXCESS PRESSURE PUMP AND APPURTENANCES FROM SPRINKLER SYSTEM <br /> RISER SV45-21 AND CONNECT WATERFLOW MONITORING DEVICES. <br /> 8. PROVIDE FIRE ALARM FIELD DEVICES THROUGHOUT 45-03 AS SHOWN ON PLANS. <br /> 600 Stewart St., Ste 1400 <br /> Seattle,Washington 98101 <br /> ISSUE FOR CONSTRUCTION Tel 206.267.1700 <br /> OCTOBER 27,2017 ``'/.7 <br /> .1$Y`' Fax 206.267.1701 <br /> SAZAN#543-1741 <br /> DRAWN DATE SUBTRtE CURRENT REVISON SYMBOL <br /> ACCEPTABILITY P.TSCHERNEGA 10.07.05 COVER SHEET W2640474 — 10.2]1 _ ' <br /> SYM REVISION BY APPROVED DATE SYM ' REVISION BY APPROVED DATE �� .'., <br /> - EVERETT FIRE PANEL REPLACEMENT 62640474 SAZAN/ZO 10.27.17 THIS DESIGN AND/OR CHECKED '2 <br /> g)1. <br /> SPECIFICATION IS APPROVED R.GWINN 03.30.06 SHEETB�E��/C® ER <br /> APPROVED B DEP. DA E REIKINN03.30.06 "`LEEVERETT FIRE PANEL REPLACEMENT /) ;I`1 <br /> — CHECKED G <br /> L.COSGROVE 03.30.06 G� I o <br /> APPROVED BUILDING 45-003 JOB ND. 'COMP NO. <br /> S.ROVED DWG N0 <br /> N 03.30.06 547160 3 <br /> S PLuUSSKKD 03.30.06 ARCHITECTURAL MASTER EVERETT, WA. ' 45-003-GO <br />