Laserfiche WebLink
(-0 <br /> ( /- —� <br /> ' � � L. I 4 �.�,� LEGEND <br /> REFER TO SHEET El FOR FIRE ALARM SYMBOLS. <br /> REFER TO SHEET E506 FOR FIRE ALARM ABBREVIATIONS. <br /> 0 <br /> j , <br /> 1 0 GENERAL NOTES <br /> M>45-003 FACT BUILDING MONITORING POINTS: <br /> ELEV 24 ALARM <br /> ELEV 24 TROUBLE <br /> ELEV 24 SUPERVISORY <br /> 1-2->FIRE CANNON FACP POINTS: <br /> F-5.5 1:12 <br /> T TRBL FLAMEOL COL. F-5.5 1:13 <br /> SUPV FLAME COL F-5.5 1:15 <br /> I MAN FLAME COL. F-5.5 1:16 <br /> _- 7>FIRE CANNON FACP POINTS: <br /> I FA FLAME COL. C-8 1:20 <br /> TRBL FLAME COL. C-8 1:21 <br /> - SUPV FLAME COL C-8 1:23 <br /> I I I <br /> 3/4"C, 4#14, #18/2C V <br /> 1 3 4"C a;1a, ,B zc FLAME DET REFERENCE DRAWINGS <br /> • <br /> _- - _ COL C-8 <br /> i V 2STROBE I� � _ .4 <br /> SV45 28 TAMPER ONLY -1 /2©O�' �� <br /> SV45-26 TAMPER SV45-24 TAMPERQ / A\110cd 3/4"C, 2#14 <br /> 2SV45-20 TAMPER SV45 34 TAMPER Q/i � <br /> ' F 1 SV45-22 TAMPER r <br /> ,n, . a"c, 2#14, #18/2c w <br /> N�, /4"C, #16/2C <br /> SEE SHEET E506-2 <br /> FOR ENLARGED PLAN ��� <br /> 0 <br /> I 1"C, 12#r4 INTO SLAB I ji 'Y MAN PULL COL C-7©' I v, <br /> v i i IIFP#2 - INTERFACE o <br /> • <br /> jj,�� 1 / PANEL ASSEMBLYQ I _ _., CONSTRUCTION NOTES <br /> • SEE SHEER E506-2 z <br /> I �% I ,,L_)__) 1�CONNECT DEVICE TO NEW SIEMENS XLS BUILDING FIRE <br /> —T FOR CONTINUATION z <br /> //. 18 ALARM CONTROL PANEL IN FOAM ROOM. SEE SHEET <br /> i/ E506-2. <br /> 0o <br /> j/ 2�CONNECT DEVICE TO NEW FIRE CANNON FIRE ALARM <br /> CONTROL PANEL. MAINTAIN EXISTING NOTIFICATION CIRCO <br /> I I1 Rork / J CONTINUITY AND SIGNALING LINE CIRCUIT ADDRESSES. <br /> II�' p% 0 <br /> 1 / 3/4" , 2414 <br /> © 1-1/2"C, 4412, 8#14, 218/2 '/ �� <br /> 1-1/2"c, 2#10, 6; 1 j 3/4"C, #18/2C, �4,4 <br /> 3/4"C, 3#18/2C ©STROBE <br /> 3/4"C, #18/2C I1 .��� rn, <br /> C>MAN PULL COL E- © 1i 1 2 2 30cd •' % WP — — F <br /> _ _ _ // �� 1/1/1 <br /> (\'i �7_ Ill - 1 �2 ` 4"11,;:2C ! i '' HANTAV �; <br /> 1= ELEV 24 FACP � �' ' BAY i i / <br /> II . II 3/4 C 1 #12:2410 <br /> ,�I� m....�Y. e 1 C, 1 2C, 4 14 d <br /> 3/4"C, 418/X, 4#12, 2#10 <br /> 1 4412, 2410 iti1 # k I <br /> In, - -1 <br /> 1�"�.1 ' �QFLAME DET COLS F_5.5Q 0 1 <br /> A- 1"c,-2#22/10C DOWN - - ,iii 1 .16�17i;`ii t — — — O a, n <br /> 21/2/1 I�1 fig L. 7, <br /> r • � FRON FOAM RM 110/1 WP P ©^w <br /> UP T CATWALK• SEE SHEET E506-2 2 UV45-24A „ © �n1� " 1"C, 5#18/2c, 4#14 j - A <br /> 1"C, 2#22/1OC DOW 23/4"C, 2#14 ''© I�I` C, 4#14, #1 /2C n� j V <br /> TO ENERATOR RM 1260 <br /> 2UV45-24A SOLENOID I 1E261 <br /> SEE SHEET 1E264 3/4"C, #18/'C IFP411- INTERFACE-J ®� <br /> 3/4"C, 6414, #18/2C 3 4,C, 22 10C i <br /> -- -- '- -- I�AFA5- 4. T.�,•F _ / , # / # I <br /> �) J <br /> V45-24A T:PE�LI` - FO' CO` IN TIO` S C ASSEMBLY <br /> 14 -- -- -- -- _- 1 __ --___] — — /C / . 1E262 1 1E263 <br /> A <br /> !_ ! _ 0 <br /> >—S ��L, � <br /> 1E265 <br /> 1E264 ■ <br /> PARTIAL PLAN VIEW O - —+ I O <br /> SCALE: 1/8"=1'-O" N 600 Stewart Sn, Ste 8100 KEY PLAN - BUDDING 45-0G3 Seattle,Washington 98101 KE, 0 <br /> ISSUE FOR CONSTRUCTION Tel 206.267.1700 B' 4. 0 4. B' 16' <br /> OCTOBER 27,2017 Fax 206.267.1701 <br /> SAZAN#543-1741 SCALE: 1/8"=1'-o" <br /> DRAWN DATE SOBTRIE CURRENT RENSION SYMBOL DATE <br /> ACCEPTABILITY ZO 10.27.17 W2640474 <br /> srM R DATE s, � APPROVED BY DATE 1N6 DESIGN AND/OR ':NECKED FIRE ALARM PLAN-FIRST FLOOR A 1 1 O. <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/20 10.27.17 SPECIFICATION 0 APPROVED ZO 10.27.17 SHEET 1 E260 0 <br /> ce;LAWEAlAW' <br /> ,ETA,INL0U TREE EVERETT FIRE PANEL REPLACEMENT r�(p' <br /> r APPROVED BY DEPT. DATE KA 10.27.17 \s, 7� n <br /> NV 10.27.17 BUILDING 45-003 IDDMP ND. r <br /> APPROVED JOB N0. <br /> W2640474 E <br /> "PPRO ELECTRICAL MASTER COL C-G/1-9 EVERETT, WA.DWG N0' 40-003-1E260 <br />