L1 U' n, <br /> is `' 4 <br /> LEGEND <br /> • <br /> • <br /> REFER TO SHEET El FOR FIRE ALARM SYMBOLS. <br /> • <br /> REFER TO SHEET E506 FOR FIRE ALARM ABBREVIATIONS <br /> • • <br /> 0 <br /> • <br /> MATCH LINE - FOR CONTINUATIOCI SEE SHEET 1E263 l �\ <br /> --j__ -- ?- -- -- <br /> i <br /> V \\\:,''', <br /> HANGAR 'IBA �' 0 GENERAL NOTES <br /> L1vii 1 ' \� — — - — — I — — __ <br /> — N. FIRE CANNON FACP POINTS: <br /> w \ i FA FLAME COL P-11 2:19 <br /> I TRBL FLAME COL P-11 2:20 <br /> Z SUPV FLAME COL. P-11 2:22 <br /> o l MAN FLAME COL. P-11 2:23 <br /> n I I i', <br /> z <br /> Z — _— — — -- —_ — — — 1 — --- — \ <br /> 0 I <br /> Ce 3/4"C, 2#14 , 11 1 <br /> o <br /> 11 UV45-24C WF 21 I <br /> 3/4"C, #18/2C UV45-24C SOLENOIDII I',, <br /> z IFP#6 - INTERF,- I'i' <br /> = MAN FLAME COL. P-11 I REFERENCE DRAWINGS <br /> PANEL ASSE STROBE • • <br /> 1 •� `___, ONLY Q i, 0 <br /> I 1/ �^�' NW Q 1/4/5 1/4/6 ill <br /> 3/4"C, 2.1 2 ♦ , 4' <br /> 11 WF lil lid"� �I W Ocd W EOLR ! <br /> 18/2C /ri.v.v,� l I- 11ocd <br /> I� O- _ 3/4"C. 2#14 — — Tl'�" - I i - - - — - --(F� CONSTRUCTION NOTES <br /> 3/4"C, I i <br /> 4#14,#18 -�Af45 24C TAMPER >CONNECT DEVICE TO NEW FIRE CANNON FIRE ALARM <br /> © UV45-24C TAMPER 3/4"C, • <br /> 2;14 FLAME DET COL. I 1 • CONTROL PANEL. MAINTAIN EXISTING NOTIFICATION CIRCUIT <br /> ©I. 5#18/2 P-11 CONTINUITY AND SIGNALING LINE CIRCUIT ADDRESSES. <br /> REPLACE SOLENOID WITH EXPLOSION PROOF SOLENOID, <br /> SAME AS INSTALLED AT BUILDING 45-04 CANNON <br /> O • <br /> INSTALLATIONS OR APPROVED EQUAL. COORDINATE <br /> SELECTION AND INSTALLATION WITH FIRE SPRINKLER <br /> PARTIAL PLAN VIEW CONTRACTOR. PROVIDE CONNECTION TO BUILDING FIRE <br /> ALARM CONTROL SYSTEM. UTILIZE EXISTING CONDUCTORS <br /> SCALE: 1/8"=1'-0" N AND CONDUIT, PROVIDE ADDITIONAL AS REQUIRED. <br /> DISCONNECT SUPERVISORY SWITCH INTEGRAL TO <br /> BUTTERFLY VALVE, COIL WIRES INSIDE OF SWITCH BODY <br /> • AND PLUG/SEAL KNOCKOUT. PROVIDE AND MOUNT <br /> SYSTEM SENSOR #PIBVEXP TAMPER SWITCH ON VALVE. <br /> PROVIDE CONNECTION TO BUILDING FIRE ALARM CONTROL <br /> SYSTEM. UTILIZE EXISTING CONDUCTORS AND CONDUIT, <br /> PROVIDE ADDITIONAL AS REQUIRED. <br /> ®REPLACE WATER FLOW PRESSURE SWITCH WITH <br /> EXPLOSION PROOF SWITCH, POTTER #PS10-EX. PROVIDE <br /> CONNECTION TO BUILDING FIRE ALARM CONTROL SYSTEM, <br /> UTILIZE EXISTING CONDUCTORS AND CONDUIT, PROVIDE <br /> ADDITIONAL AS REQUIRED. • <br /> DISCONNECT AND REMOVE SUPERVISED VALVE. PROVIDE <br /> • UL LISTED AND FM APPROVED GATE VALVE AND POTTER <br /> #OSYSO-EX TAMPER SWITCH. COORDINATE VALVE <br /> SELECTION AND INSTALLATION WITH FIRE SPRINKLER <br /> CONTRACTOR. PROVIDE CONNECTION TO BUILDING FIRE <br /> ALARM CONTROL SYSTEM, UTILIZE EXISTING CONDUCTORS <br /> AND CONDUIT, PROVIDE ADDITIONAL AS REQUIRED. <br /> u * <br /> ry <br /> - 1260 I <br /> 1E261 <br /> I ®. <br /> 1E262 1E263 ,I <br /> ,. '": 1E264'I <br /> 600 Stewart St., Ste 1400 L J 1 <br /> Seattle,Washington 98101 KEY PIAN - BUIDIIvG 45-003 0 <br /> ISSUE FOR CONSTRUCTION 0 Tel 206.267.1700 8' 4' 0 4' 8' 16' <br /> OCTOBER 27,2017 Fax 206.267.1701m MINI <br /> SAZAN#543-1741 - —._.=.—___.O_—. __—.. <br /> SCALE: 1/8"=1'-0" <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL I DATE <br /> 5YM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY 20 10.27.17 FIRE ALARM PLAN-FIRST FLOOR W2640474 A toz7.t7 <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 10.27.17 - THIS DESIGN AND/OR ZO�NM 10.27.17 SHEET 'e <br /> • <br /> SPECIFICATION IS APPROVED <br /> ce;LATOE,AW® CHOIN ITE EVERETT FIRE PANEL REPLACEMENT 1E265 f a/� g <br /> APPROVED BY DEPT. DATE KA 10.27.17 <br /> CHECKED 8 <br /> KA 10.27.17 BUILDING 45-003 " <br /> APPROVED ,we ND. W2640474 CONT a <br /> APPROVED ELECTRICAL MASTER COL. M-P/9-15 EVERETT, WA.°NG NO. <br /> 45-003-1E265 <br />