Laserfiche WebLink
/.E WIRE CODE (THIS SHEET ONLY): <br /> ® ' LEGEND <br /> A = 2#16 TFN OR TFFN (STRANDED OR SOLID) <br /> FIRE CANNON FACP + -) <br /> TO SLC#1 CIRCUIT DEVICES B = 2#14 THHN (STRANDED) REFER TO SHEET El FOR SYMBOLS AND ABBREVIATIONS. <br /> SIEMENS <br /> �A XLS E ` SLC#1 CIRCUIT WEST ScOUTH SIDE OF HANGAR C = 2#12 THHN (STRANDED) REFER TO SHEET E506 FOR FIRE ALARM ABBREVIATIONS. <br /> S I E M E N S — /�LS D = 2110 THHN (STRANDED) <br /> ® E = #18 TWISTED SHIELDED PAIR (TSP), TYPE FPL OR CM <br /> + TO SLC#2 CIRCUIT DEVICES LOW CAPACITANCE CABLE (LESS THAN 30pF/FT) <br /> SLC#2 CIRCUIT EAST SIDE OF HANGAR <br /> ©—"X" DENOTES CABLE OR WIRE PAIR <br /> NUMBER. MARK CABLE OR PAIR WITH <br /> B NUMBER OR LETTER INDICATED. <br /> 1 C .. <br /> 1 NAC CKT A/2, MECH RM 144 <br /> `+ <br /> /' . I H�1 EOLR <br /> A/2/1 A/2/2 GENERAL NOTES <br /> B <br /> + NAPI,TB1-1 <br /> NAPI,TB1-2 SEE SHT. E506-5 <br /> 1 ` <br /> 1 <br /> e-- <br /> ✓ + FS1-1(+) 24VDC TO WEST SIDE SEE SHT. E506-4 <br /> • - . FS1-2(-) UV/IR FLAME SENSORS <br /> © , + FS1-1 + 24VDC TO EAST SIDE <br /> ( ) SEE SHT. E506-4 <br /> B _ FS1-2(-) UV/IR FLAME SENSORS <br /> B- ' REFERENCE DRAWINGS <br /> WEST SIDE FORWARD WEST SIDE AFT <br /> B MONITOR STATION SOLENOID VALVE MONITOR STATION SOLENOID VALVE <br /> S1+ AQP SV1 1 S2+ —11 SV2 <br /> 78 51- 1�b�/) l S2- (��/) <br /> EAST SIDE FORWARD EAST SIDE AFT <br /> B MONITOR STATION SOLENOID VALVE MONITOR STATION SOLENOID VALVE <br /> S3+ - SV3 e 1 S4+ SV4 <br /> 7B S3- S4- <br /> 0 <br /> APS <br /> AUX. POWER SUPPLY CONSTRUCTION NOTES <br /> 24VAC 1 -• <br /> — <br /> 24VAC 2—' RECONNECT ALL EXISTING CIRCUITS TO NEW SIEMENS XL <br /> --� BATTERY+ 3 HANGER SUPPRESSION FIRE ALARM CONTROL PANEL, BY <br /> BATTERY- 4 . EC, AS SHOWN. <br /> DC OUT+1—+ <br /> I00i 1 120 VAC INPUT DC OUT -T <br /> p . HN6 FAULT± 4 <br /> 1 ~ <br /> 1 - TO J <br /> L / / ANNUNCIATOR <br /> E B PNL. ALARMSAF MODEL: RPR-1 <br /> , ,,, AS/PS5-BES-24UL +- I IPWR. SUP <br /> 3#12—/ 1 12 3 41 TRBL. RELAY <br /> I 12OVAC CIRCUIT, DEDICATED E-,,,,,, )J<���470n <br /> ` <br /> TO FACP,MMB3,P2 B,, o, • <br /> (BATTERY IN.) <br /> DIi t D D IJ b D <br /> BATTERY BATTERY BATTERY BATTERY <br /> : .. ; 'at <br /> FACP WIRING DIAGRAM 600 Stewart St., Ste1400 <br /> O DEVICE WIRING DIAGRAMS Seattle,Washington 98101 <br /> SCALE: NONE E506-3 SCALE: NONE <br /> E506-3 ISSUE FOR CONSTRUCTIONA� Tel 206.267.1700 <br /> OCTOBER 27,2017 Fax 206.267.1701 <br /> SAZAN#543-1741 <br /> GYM REVISOR FW APPROVED ''. DATE ST11 '',. RENSION BY gPPItOYID DATE DRAWN DATE BUBDRE CURRENT RESISK)N SYMBOL DATE <br /> ACCEPTABILITY ZO 09.30.16 FIRE ALARM DETAILS- W2640474 — 10.27.E <br /> - EVERETT ARE PANEL REPLACEMENT W2640474 SAZAN/ZO 10.27.17 THIS DESIGN MND/OR tNll.KEu sHEEr <br /> `` <br /> SPECIFICATION IS DEP. DD FKNDCINEER 09.30.1616 Tins FIRE CANNON E506-3 ek) <br /> BOi,�W® APPROVED B DEPr. DA E CH09.30.16 EVERETT FIRE PANEL REPLACEMENT�.J� CHECKED• ROVED KA 0930.16 BUILDING 45-003 JOB ND. W2640474 `D" <br /> • ROwD ELECTRICAL MASTER EVERETT, WA.DWG NO. 45-003-E506-3 <br />