Laserfiche WebLink
Permit#: B1901-025 <br /> , Site Address: 2201 COLUMBIA AVE <br /> c. Owner: HAALA ANNA R <br /> PROJECT SITE Tenant: [TenNamej <br /> PHOTOVOLTAIC NOTES 1 / SCOPE OF WORK App.Date: 1/22/2019 <br /> 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL INSTALLATION OF ROOF MOUNTED SOLAF Proposed Use: SFR DETACHED <br /> MODEL#:IT-300-SE 301 <br /> DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK - it- I' NEW EQUIPMENT: 30 Description: INSTALL OF PV SOLAR ROOFTOP SYS I EM <br /> UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL ' - C - '` $ fi ITEK ENERGY MODULE <br /> PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) `"" j, 30 P320 SOLAREDGE OF 9KW <br /> 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SE7600H-US <br /> THREAD-LESS COMPRESSION TYPE. - t ,_. -ffi , _ I SOLAREDGE HD INVEF <br /> 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED ..i,t SYSTEM SIZE: 9.000 DC KW RATING <br /> 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER RevI ed By: <br /> DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES.TERMINAL CABINETS, D 7.600 CEC AC RATING Date: <br /> ETC.ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO r SPIDER-RAX BLACK WIDOW CO <br /> RACKING: <br /> WITHSTAND THE WEATHER. - - • - _ _ SYSTEM Office Set ..OBJ Site Set Fire/Planning Set <br /> 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR ' ARRAY AREA: 18.05 SOFT x 30 = 541.50 1 <br /> APPROPRIATE WATER RUN OFF. ,. 1 <br /> 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION - ',- <br /> BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. ( ig I '1' • SITE DETAIL <br /> 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS $ '• UTILITY: SNOHOMISH COL <br /> 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD ', i< ELECTRIC SERVICEN/A <br /> APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. j ="' : 041101- 11 energy tunny <br /> 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE I • * ROOF MATERIAL: COMPOSITE SHINGLE <br /> WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF I T ASCE 7 GROUND SNOW LOAD: 25 PSF <br /> MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BYA FLEXIBLE WIRING SYSTEM. -- ' - ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) S 0 L A R <br /> (NEC 690.34) RISK CATERGORY I: 100 <br /> 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE <br /> FOLLOWING WARNING AT EACH JUNCTION BOX.COMBINER BOX,DISCONNECT AND DEVICE WHERE THE - RISK CATEGORY II: 1 1 0 <br /> UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD. - - RISK CATEGORY III-IV: 1 1 5 <br /> THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT } •tt, <br /> MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND d6 „__ ASCE 7-05 WINDSPEED: 85(3 SEC PEAK GUST IN MPH)FAULTS."(NECE690.35(F)) " c� _ _ ASCE 7-83 WINDSPEED: 71 (FASTEST MILE IN MPH) , 1111 <br /> d ,t. NIL <br /> s <br /> 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE '- -. t <br /> _ <br /> PROTECTED FROM ANY PHYSICAL DAMAGE. ; x -• - .N.,•-- -' CODE AUTHORITY 1001 COOPER POINT <br /> 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING 2015 WASHINGTON STATE BUILDING CODE(2015 IBC) RD SW,STE 140-290. <br /> AGENCY. <br /> 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. �1 ,_ "";'j�n r I 1 As 2015 WASHINGTON STATE ENERGY CODE(2015 IECC) OLYMPIA,WA 98502 <br /> 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER _ ,: - 2015 WASHINGTON STATE RESIDENTIAL CODE(2015 INTERNATIONAL PHONE:360-637-4343 <br /> 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, - RESIDENTIAL CODE WASHINGTON AMENDMENTS 2014 WAC51-51-2300 <br /> COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED SECTION M2302) HEIDI PASCHAL <br /> 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE 2017 WAC 296-46B(2017 NEC) PROJECT MANAGER <br /> CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. <br /> ` SITE MAP 2017 WASHINGTON CITIES ELECTRICAL CODE(2017 WCEC) <br /> 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY <br /> ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED 2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC) <br /> AS APPROPRIATE. 2015 WASHINGTON STATE PLUMBING CODE(2015 UPC) <br /> 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 2015 WASHINGTON STATE FIRE CODE (2015 IFC) 9.000 DC KW <br /> SPECIFICATIONS.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL <br /> MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN - 7.600 KW C EC-AC RATING <br /> THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM SHEET INDEX <br /> REQUIRED BY THE ARCHITECT/ENGINEER. A-1 GENERAL NOTES,SHEET INDEX,BUILDING&PROJECT DATA CENTRAL INVERTER SYSTEM <br /> 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED A-2 SITE PLAN <br /> OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. A-3 WIRING&MOUNTING PLAN 23° 90°, 180°,270° <br /> 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. TILT AZIMUTH <br /> 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE E-1 ELECTRICAL SINGLE LINE DIAGRAM <br /> WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING E-2 ELECTRICAL CALCULATIONS <br /> PIPING SYSTEMS. E-3 LABELING REQUIREMENTS <br /> 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING E-4 EQUIPMENT:PV MODULE SPECIFICATION SHEET <br /> CONSIDERATION OFA^P AND RAP BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE ';lUdlson Si FMJd150.'1 St 14c dl. -" 2201 COLUMBIA ANE <br /> SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC E-5 EQUIPMENT:INVERTER SPECIFICATION SHEET <br /> LATERAL FORCE DETERMINATION. E-6 EQUIPMENT:DC/DC OPTIMIZER SPECIFICATION SHEET EVERETT, <br /> 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB - ,' S-1 EQUIPMENT:RACKING SYSTEM WA 98203 <br /> SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. qE, 3 <br /> 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING S-2 EQUIPMENT:RACKING SYSTEM AP.,.. _ . s .._::+, ''�'� <br /> NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR 2' .4 ,a`.1 S-3 EQUIPMENT:RACKING SYSTEM A • ::...3m ayl�;:. tom,.-s r`'•. `• ANNA HAALA <br /> DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE <br /> TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE ! , , <br /> i I (206)321-9355 <br /> AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A '2201 Columbia Avenue I I <br /> MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. �/ <br /> 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW JAN 22 2019 .� <br /> ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 1 10.26. APN:00545001701700 <br /> 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.601, <br /> 310.8 D) <br /> 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE 1:0 tO t'...A.:, e,e. CITY OF EVERETT <br /> DC SIDE OF THE SYSTEM.(NEC 250.97) T Bre permit Services <br /> 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF <br /> SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) - <br /> 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT - GATF DESCRIPTION <br /> BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) <br /> 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC <br /> 250.64(E) 95.xvI. ,I <br /> 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. <br /> A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED <br /> CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER '°���,L,'"S�(.7.N,-, <br /> 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. SV;,/ .,, t R <<:.. ! DATE 1/14/19 <br /> 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR / 1 I . DRAWN: <br /> ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC �/_\ <br /> 93.690.31(El `\� VICINITY MAP DRAWN BY: PD <br /> 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, , <br /> JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S J(��) 7 <br /> INSTALLATION INSTRUCTIONS LAMC 93.690.1 10.3&93.1 10.3(8). JA - ` 28,3 1 <br /> �! J/LJ 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE <br /> STAINLESS STEEL LAMC 93.110.3(B). CITY(IF <br /> F -•,-1 GENERAL <br /> 36.NO PIPING.DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE 11 r <br /> LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT.37.ALL FIELD INSTALLED Per VER E NOTES <br /> SHALL BE ACCESSIBLE DIRECTLYOOR BY DISPLN.PULL ACEMENT OFA MODUTLET BOXED ULE(S)OR PANEL(S)SECURED BYTED BEHIND MODULES OR ELS mfr SeF'V j CeS ! DATA <br /> REMOVABLE FASTENERS. 1 p 1p\O J E C 1'T' DATA <br /> 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE <br /> BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC <br /> SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. <br /> 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING <br /> MATERIAL SHALL HAVE THE SAME OR BETTER LIS I ED FIRE-RESISTANCE RATING THAN THE BUILDING <br /> ROOF-COVERING MATERIAL. <br /> 40.ALL ROOF MOUNTED CONDUIT WILL BEA MINIMUM 6"OFF THE ROOF SURFACE. l / 7 <br /> A . i <br /> J <br />