Laserfiche WebLink
.�,-..... _ <br /> Permit#: B1901-017 <br /> Site Address: 9930 EVERGREEN WAY <br /> Owner: THS SNOHOMISH LLC <br /> Tenant: THERAPEUTIC HEALTH SERVICES <br /> App. Date: 1/11/2014 <br /> � Praposed Use: CQMMERCIAL <br /> Description: TENANT IMPROVEMENT-NEW ADA <br /> RESTROOM,BREAKRM <br /> Reviewed By: ���� Qate: I7�-���� ���- <br /> TYOfFice Set Job S�e Set Fire/P)anni� �ig Set <br /> � <br /> � <br /> w <br /> F- <br /> C� <br /> � � Z O <br /> � � <br /> N � <br /> � <br /> Wc�i� <br /> � w <br /> 0 <br /> DESIGN TEAM <br /> OWNER: PROJECT ARCHITECT: ELECTRICAL ENGINEER: MECHANICAL ENGINEER: � <br /> THERAPEUTIC HEALTH SERVICES BOTESCH, NASH & HALL ARCHITECTS, P.S. AWA ELECTRICAL CONSULTANTS, INC. RICE GROUP, INC. <br /> 9930 EVERGREEN WAY 2727 Oakes Avenue 19�15 36th Avenue West, Suite E 20201 Cedcrr Valley Road, Suite 120 � <br /> EVERETT, WA 98204 Suite 100 Lynwood, WA. 98036 Lynwood, WA. 98036 � � M <br /> 425-3475121 Everett, WA 98201 (425) 775- 1799 (425) 774-3829 = �N <br /> MarliB@THS-WA.gov (425) 259-0868 FAX 774-9870 FAX 672-2084 osf QN <br /> Email: bnh@bnharch.com s � �N <br /> � �� <br /> � �- � x <br /> GEN ERAL N OTES ABBREVi ATI ON S SYM BOL LEGEN D PROJECT DATA DRAWI N G I N DEX Z � �`� <br /> �, w <br /> � � <br /> c� � o . <br /> I. A1l construction shabl comply with the 2012 lnternationati Building Code (IBC), A � ENG ER'AL � +., o <br /> Washington State regulations for barrier-Free design, Washington State Energy q,g, ANCHOR BOI.T L LONG; LENGTH DATUM POINT Pf�OJECT NOf�TN MAJOR' APP'LICABLE CODES � � � � <br /> Code, and all Qpplicable 1oca1. codes, ordinances and standards. ABV ABOVE LAM LAMINATE GI.O COVER SNEET '�"' U �' °O <br /> WTEf�NATIONAL BUILDING CODE - 2015 . o <br /> A/C AIR CONDITIONING LAV LAVATORY O � � � <br /> 2. The Contractor is to veriFy ati1 existing conditions, dimensions, details, etc, ACT ACOUSTICAL CEILING TILE tb, rc PouN� WASNINGTON STATE BUILDING CODE m Q � o, <br /> a� AREA DI�AIN LF LINEAR F00T DETAIL NUMBER CNAPTER 51-50 WAC A�CHITECTURAL _� <br /> and notiFy the Architect oF any and a1l discrepancies prior to proceeding with the ADJ ADJUSTAB�E LL LIVE LOAD � N <br /> work, qpF ABOVE FINISN FLOOa �oC LOCATION INTERNATIONAL pLUMBING CODE - 2015 > � <br /> ALUM ALUMINUM LT LIGHT � NORTH WTEI�NATIONAL MECHANICAL CODE - 2015 AS1.0 SITE PLAN Q "' <br /> 3, Do not scale drawin s; dimensions overn. The Contractor shall notiF the ALT ALTERNATE �P LOW POINT A-000 WASNINGTON STATE ENERGY CODE - 2015 ������'��'��������'�'�,��"�`������� AD1.0 DEMO FL00� PLAN ; �� <br /> 9 9 Y aP�Rox aPpRoxiMare � �`'���V�� ��� ��i' ��u���'����� AI.O FLOOR P'LAN � � � °-' <br /> Architect immediately oF any and ati1 discrepa�cies. The drawing scales are ARCH ARCHITECT M t � ��.�c�Li��1�1��?K�, i�����i;�i�l�.�,a, �i�� o 0 <br /> indicated to providc visua1 pro portion and shou l d be veriFied with similar drawin gs •. SNEET NUMBEI� DOOR NUMBER Z O N E C L A S S I F I C A T I O N ` �� A2.0 REFLECTED CEILING PLAN <br /> ASPH ASPNALT MAS MA50NRY ��-������"����"� ����%��'�����-�� � �- <br /> and listed dimensions. � , ° � A3.0 ROOF PLAN s N Q, <br /> AUTO AUTOMATIC E-IMUO E-I MIXED-USE OVEI�LAY <br /> A G G. A G GRE GATE MAT MATERIAL 001 ����t����� ����'�'d����• A�,O INTEf�IOR ELEVATIONS � °-' <br /> 4. Atl dimensions are to be center line of stud, or face oF cancrete wall, unlessN~ <br /> noted otherwise. B rMi cu MECNANICAL DETAIL NUMBER A8.1 DETAILS <br /> MFD MANUFAGTURED WINDOW NUMBER CONSTRUCTION TYPE (CNAPTER 6� <br /> Bo BOAR'D � TYpE VB (NON-SPRINKLEI�ED) Aq.O SCNEDULES <br /> BLDG BUILDING MFR MANUFACTURER <br /> 5, Where device5 or item5 ar parts thereoF are referred to in singular, it is BLK BLOCK MH MANHOLE A-000 � ELECTR�ICAL <br /> intended that such shatiti apply to as many such devices, items or parts as are BLKG B�OCKING MIN MINIMUM OCCUPANCY TYP'E (CNAPTER 3� <br /> reqyired to properby compkte the work, B�w BE�ow B �..��u� f �� ����`�� � � <br /> MISC M15CELLANEOUS �' • t <br /> M,O, MASONRY OPENING WALL TYP'E <br /> eM BEAM SHEET NUMBEI� � E0.0 COVER SNEET <br /> 6, It shall be the res onsibilit oP the Contractor to locate a1l existin util.ities B,M. BENCH MARK MTL ME7A� ��.�'���:'��`� ��� S" ����Y� E0.1 ENERGY CODE PANEL SCNEDULES <br /> P Y 9 BUILDING AREA: � <br /> BRG BEARING OO <br /> whether shown hereon or not and to protect them From damage. The BSMT BASEMENT N SECTION NUMBEI� BUILDING 14 805 SF EI,O LIGHTING PLAN <br /> Contractor shall bear a�ti expense oF repair or replacement oF uti�ities or other BTM BOTTOM N NORTH ' E2.0 P'OWEa P'LAN <br /> property dc�naged by operations in conjunction with the execution oF his work, BTWN BETWEEN NA NOT APPLICABLE p PROJECT AREA: 2,706 SF E3.0 RODF PLAN <br /> NIC NOT IN CONTF�ACT A-000 <br /> 7, The Contractor witil veriFy and conForm to a11- reqy�irements of a11- uti�ity C NO NUMBER � �/�� <br /> companies, unk55 noted othtrwiSC in the "(ans and s eciFication5. CAB CABINET NOM NOMINAL MECNANICAL VJ <br /> p p C,B. CATCH BASIN NTs NOT TO SCALE SHEET NUMBER ROOM NAME <br /> c� CONTROL JOINT �� �q�d��o���� ����i���,r� ��quir�d M0.1 MECNANICAL LEGEND NOTES AND SCNEDULES � <br /> 8. Existing elevations and locations to be joined shalti be verified by the C�,(� CENTER LINE � R�QM <br /> Contractor beFore construction 'Iayout. If they differ From those shown on the c�G CEILING oA OVERALL WALL SECTION LETTER ���'�"Mj� �r�jecf`�o In�lude: MDI.I MECNANICAL DEMOLITION FL00f� PLAN � <br /> CLO CLOSET O.C. ON CENTER (S) OOI � <br /> drawings, the Contractor shatiti notify the Architect, so modiFications can be made c�a C�EAR MD1.2 MEGNANICAL DEMOLITION I�OOF pLAN <br /> beFore roceedin with the work. CMU CONGRETE MA50NRY UNIT �D OUTSIDE DIAMETER Q <br /> p 9 OPNG OPENING � rinkl�� Mi.o MECNANICAL UNDER FLOOR PLAN <br /> co CLEAN OUT A-000 ROOM NUMBER �.�� �������� p � <br /> oPP OPPOSITE MI.I HVAC FLOOI� PLAN <br /> q, A1l debris shatiti be removed From the premi�es and atiti areas sha�� be 1eFt in COL COLUMN p.F.C.I. OwNER FURNISHED- ��g y, d (��'' Fj�'�/����� W <br /> CONC GONCRETE CONTRACTOR INSTALLED � g�Ii��lf����i�i F MI.2 MECNANICAL ROOF PLAN <br /> broom c�ean condition at all times. CONT CONTINUE (CONTINUOUS) O,F,0.1, OWNER FURNISHED- SNEET NUMBEf� M2.� pLUMBING FL00(� pLAN � <br /> cTR COUNTER OWNER INSTALLED �Y � �I�C��'1C�� M3.1 MECNANICAL DETAILS AND DIAGRAMS � <br /> 10. The Contractor shatiti take alti necessary precautions to ensure the saFety oF cPT CARPET � INTEfiIOR ELEVATION NUMBER M4.1 f`1ECNANIGAL SPEGIFICATIONS = �, <br /> the occupants and workers at a1b time5. C.F,0,1. CONTRAGTOf� FURNISHED- P <br /> OWNER INSTALLED P'ER PERIMETER � � � <br /> II, Fire extinguishers: Verify the reqyirements and locations with the fire PL P�ATE 4 A-o00 2 'J <br /> marsha1. The Contractor is to su � fire extin ui5hers and cabinets as re ired � P.L. PROPERTY LINE � <br /> PP Y 9 � �lY DBL DOUBLE PLAM P'LASTIC LAMINATE � <br /> _ and/or as indicated on the drau�ings. DF DRINKING FOUNTAIN PLBG PLUMBING W <br /> DIA � DIAMETER PLF p0UND5 PER LINEAR FOOT 3 SNEET NUMBER T �j,� <br /> 12. Sound insulate a11 p1umbing walls. DIM DIMENSION PLYWD PLYWOOD , � .,L,. 1,1 <br /> DISP DISPENSER PNT pAINT (ED) ������''��� �t��� '�5���¢��� W <br /> � 13, The plQns and speciFications are minimums and where details are not pp DEEP �'a PAIR � 4 I' 1 � � <br /> speciFically shown, consistent practices �ha�� be used. Codes and ordinance5 take DTL DETAIL PREFIN PREFINISHED I-NR WALL �1�r u <br /> PSF P'OUNDS PER SQUARE F00T � "���l������'a�� � <br /> precedence over plans and speciFications and wherever inconsistencie5 exist, it wi11 DS DOWNSPOUT pSl POUNDS PER SQUAR'E INCH r <br /> be the Contractor's responsibility to immediatetiy notiFy the Owner and provide PTN PARTITION � <br /> acceptabk corrections at no additionati charge, E E EAST PVG POLYViNYL GNLOf�IDE 2_�� WALL '� W .. <br /> I4, Use 5/8-inch GWB T e X in atib locations unless noted othcrwise, EA EACH R � � � <br /> � YP , EB EXPANSION 60LT RA RETURN AIR W W <br /> EJ EXPANSION JOINT RCP REFLECTED CEILING P'LAN 2-N� SMOKE WALL � <br /> 15, The Contractor shatil proVide mechanica1,, plumbing and electricati permits. EL ELEVATION RD ROOF DRAIN <br /> ELEC ELECTRIG (AL) RECPT REGEPTACLE � O � <br /> 16. 5heet-metaL flashing at skylights, roof hatches, rooftop mechpnica� units, Ep EQUAL REF REFEaENCE/REFRiGERATOR W (� W <br /> EOUIP EQUIPMENT q-NF� WALL <br /> masonry head si�1s, soFfits, parapet wa�(s, reg�ets, eXpansion joints, etc., shotil El� EACH WAY REINF REINFORCE (MENT) T � a <br /> be instalkd as rccommended by SMACNA (Sheet Meta1 and Air Gonditioning Ex�ST EX�ST�NG REO'D REOu�RE (D) �� � <br /> EXT EXTERIOPo REV REVISE(D);REVISION;REVERSE � � <br /> Gontractors National Association) manua�. �M RODM Q � <br /> R,O. ROUGH OPENING <br /> 17. Penetrations through rated construction shdbti be protected by U.L. Listed T F k,o.w, RIGHT OF WAY <br /> sto materiabs and methods er IBC 2012. FD FLOOFY DRAIN a,T,U, ROOF TOP UNIT KEYNOTE NUMBER <br /> P p FDN FOUNDATION <br /> FE FIRE EXTINGUISHER �B RE5ILIENT BASE <br /> I8. Seating caulking and weather-stripping sha11 be installed to proVide a FEC FIRE EXTINGUISHER CABINET L E G A L D E S C R I P T I O N 3��s <br /> complete building envelope FH FIRE NYDRANT 5 S SOUTH � REGISTERED <br /> FIN FINISN 5AN SANITARY � ARCHITECT <br /> Iq. Prior approval is reqyired on a1ti changes or alterations to the approved plans. FIN FLR FINISH FLOOR 5B SPLASN BLOCK DEMO KEYNOTE NUMBER <br /> FLR,FL. FLOOR SC SOLID CORE <br /> FLUOR FLUORESCENT �N SCHEDULE MqTCN L I N E P'ARCEL NUMBER: 28041300306500 ANDREW M A <br /> FR FRAME(D)(ING)/FIRE RATED SD STORM DRAIN <br /> FT or (') FOOT SEAL SEALANT STATE OF WASHINGTON <br /> FTG FOOTING sF SG?UARE FOOT � �� � SECTION 13 TOWNSNIP 28 RANGE 04 QUARTER SW LOT 3 OF EV BUSWESS PK BSP <br /> FUR FURRED/FURRING SHT SHEET <br /> G COE FILE NO 05-001 REC UND AFN 200512065006 BEING PTN Sl/2 SWI/4 SD SEC 13 , <br /> �a GAUE, GAUGE sPEc SPECFGATION PICTURE NUMBER (DOR EXEMPT PEa STATE OF WA REG # Oq420-002) <br /> GALV, GALVANIZED -`� SQUARE <br /> � GB GRAB BAR SERV SERVICE O JOB NUMBER <br /> GC GENERAL CONTRACTOR SS SANITAaY SEWER f�EVISION CLOUD 1�'i��� <br /> V I C I N I T Y M A P SST STAINLE55 STEEL <br /> GL GLA55, GLAZING oATE <br /> Gt^lB GYPSUM WALLBOARD-TYPE X STG SOUND TRANSMISSION CLASS <br /> STD STANDARD <br /> 5TL STEEL REVISION NUMBEI� � <br /> 1�1i 2�1i�1 <br /> _ v.-- U_ _ . : �,�._: � H ST5 STORM SEWER oRAWN Br <br /> .; t� � NG HOLLOW CORE STRUCT STRUCTURAL; STRUCTURE �� - <br /> r�c�:�on� �s t, o�ar� �� � uaa,��� � C�..x �� ` � NDR' HEADER SUP'� SUPPLY <br /> � ��vFe��t�n "' s� r"„ �' NDt^i HARDWARE SUSP 5USPEND (ED) CHECKED BY <br /> aAparhneniHumc3 fr�d d.,y�r �, j4 ,� «en HDNiD HF�f�DW�OD <br /> i cy;�a�sP��,ss� � e+' � � � �� . 54V STAIN t VARNISH <br /> 4 Ao�rtments� � {;�,�S pj Q w p}}iq t; ,� �:, NM NOLLOW M ETAL �H <br /> � �. � ���������,��,q�����,,�,� ,;; HORIZ HOI�IZONTAL SWS STORM WATER SEWER <br /> b <br /> - �' �j r�,s�rl HP NOf�SE POWER' �' <br /> t�t�srr��Qptr � �� � .� '��3 ��� � �'�� �� ` �?������i����.� � ��r� HTG HEATING T_O.C. TOP OF GURB � � <br /> SHEET TITLE <br /> ' � � ' �� � �� � � � ' � ���`��'�`� � � � �� ,° '� �F����� HTR HEATER TELE TELEPHONE SECTION LE E(� <br /> = x s � ' � °} , ' TEMP TEMPORART Tr <br /> P„*�i,k�,tp�xti {°" , , t�u,�u,,ioFlkark ` : HVAC HEATING VENTILATING <br /> � = � `�'� "� ' �m ��a tm•nis� �� ` ��;'e_. ' TSG TONGU E d GROOVE <br /> � �- � � ` �� � AND Alf� CONDITIONING XX - - XX <br /> � � � � � �� "'�� � � WW NOT WATER TV TELEVISION � yy�.y �y � <br /> "�"'" � �tP�,1'cR�.`I�'� ��+���t9� .+lE61"! v,d�r,ut',s��;ercu+uar� - � T.O.B. TOP OF BEARING - �/�„/�E�7 � <br /> � �� , , . � �� ; ���; T.O,P. TOP OF PARAPET <br /> �es�sr � h ' a I EE <br /> T.0,5. TOp OF ST L <br /> ` ry � � �� T.O.W. TOP OF WALL <br /> 9��sn . . ,. � , " +.^�-t . ID INSIDE DIAMETER / $HEET <br /> �� �h..�. � � �.�.��,�„��s ws , " TYP TYPICAL - <br /> ; � - � F ,r a . i -� ., � . s� � , � Q� INCL INCLUDE <br /> z � , <br /> � <br /> � a <br /> ; :��� F�up } �"� :' IN or ���� INCH U V W 8C Y <br /> 3 �,a s �y '. ` X ��:4i� r.� �, � INSUL INSULAT10N > > _ _ � � <br /> �r�:e r�t.,ii <br /> SITE �� - �� iNr iNreRio� v vo�r �`��. <br /> " =, � �t�������.��,� ��«,r <br /> ������a � � �� p�,n3�K�P�x� � � � V.C.T. VINYL COMPOSITION TILE '� �� ` �� <br /> � , <br /> '_"'_. - i .' � . . <br /> ' "` J VERT VERTICAL �� COLUMN GRID REFERENCE <br /> � a` �' '�� �� �'�T375iy.e lrat4s�Ftxed.;.� �� SHEET NUMBER <br /> 0 <br /> 9..��;,, ;Y o� x � � JST. JOIST W WEST � / / <br /> ,h�`� 8(� n��: I�i1T,R WATER' � I L <br /> t � <br /> .� , <br /> � � <br /> _ � j � � � a, .� Eiilfl43`a�ir�9�Pe! , � �� � �'`V W�TN 1 °' � � • <br /> �A(YSr�n�kaks , �'`"fi, `� z�� _ <br /> '� �` W.C. WATER CLOSET � W <br /> , � � '� KW KILOWATT �.yD WOOD ' �T <br /> �t�ds Q � �5 sor�r�..�f�t�:�btt�o�t+3 : ' �'"`"�e: � _�`� � WH WATER HEATER � <br /> � �,m .., � , . rn, . f �cra pUiin cnt � ,� t�a� <br /> �. �veaeA om��F���e � �� � � , 3 � J , � � � � � - <br /> �,P,�w ra, _r , � � �Gv.sc4'��h W/0 WITHOUT � ■ <br /> 5 v--��° � WT WEIGHT � <br /> �' � ' ` � n � # : W.W.F. WELDED I�IIRE FABRIC � <br /> �qs�,�swa tG Gsi . . �SFrlrLz.ek�'� �� � <br /> �k�e�n�ocda+`�� � diPi;t,st���C� �a�ri,.a' ' = tu,�f 3u4��n�nS} � W.W.M. WELDED WIRE MESN W <br /> � <br /> < � � , � �,... :. . <br /> � ,. ,:. YD YARD <br /> Q <br /> � # � <br />