Laserfiche WebLink
--j-- <br /> � <br /> Oo � Oo <br /> o � O o <br /> 00 0� <br /> , <br /> , ; � <br /> � <br /> � i � � <br /> i � � � EXISTING UNIT 3 <br /> 1-BED UNIT 427 SF <br /> � � <br /> � � ti��� � <br /> EXISTING UNIT 1 r � <br /> mr ' � �:�,\ <br /> RF STUDIO 330 SF — <br /> �-�►-- � .�!� '� , �.);..o. <br /> .�J_'r���� <br /> ��1� � � <br /> � .,�. � ( � <br /> � ns <br /> O - - --- <br /> RF <br /> RF O ---- - <br /> o � � WALL TYPE LEGEND <br /> 0o O <br /> � � � � <br /> TYPICAL NEW EXTERIOR WALL � `- � � '� <br /> I I co ri v ai <br /> COMMON AREA EXTERIOR WALL SIDING o/(2) LAYERS 60#BLDG. PAPER o/ 1/2" p N N N c� <br /> 324 SF I I OSB SHEATHING o/2x6 WOOD STUDS AT 16"oc w/5/8" GYPSUM o 0 0 � , <br /> WALL BOARD AT INTERIOR. PROVIDE R-21 BATT INSULATION. <br /> TYPICAL NEW INTERIOR WALL � � � F <br /> (U.N.O.)ALL INTERIOR WALLS SHALL BE 2x4 WOOD STUDS OR w w w w <br /> 2x6 (WHERE PLUMBING REQUIRED)WOOD STUDS @ 16"oc w( � � � � <br /> 5/8"GYPSUM WALL BOARD EACH SIDE. O O O O <br /> Z C� U U U <br /> TYPICAL NEW INTERIOR OR EXTERIOR EXISTING WALL O <br /> EXISTING UNIT 4 � <br /> 2x4 OR 2x6 WOOD STUDS @ 16"oc INTERIOR OR EXTERIOR. a w w w w <br /> 1-BED UNIT 442 SF <br /> � � <br /> --------- TYPICAL DEMOLITION WALL cvi� Q Q Q Q <br /> --------- WALLS TO BE DEMOLISHED. p w w w w <br /> o � o ❑ <br /> TYPICAL CONCRETE WALL C� c� C7 C� <br /> CONCRETE WALL SPECIFIED BY STRUCT. ENGINEER z z z z <br /> 0 0 0 0 <br /> J J J J <br /> O � 0 , m m m m . <br /> � <br /> c� � waaaa <br /> SYMBOLS � <br /> �p HARDWIRED INNER CONNECTED SMOKE DETECTOR <br /> WITH BATTERY BACKUP. <br /> E <br /> OCD/SD HARDWIRED INNER CONNECTED CARBON MONOXIDE/SMOKE DETECTOR <br /> COMBO WITH BATTERY BACKUP. 423 � . <br /> O � <br /> � O�O � PER TAB E M 507.3 31LATION FAN REGISTERED <br /> WHV � � ARCHIT�ECTS <br /> EXHAUST FAN <br /> O � SEE TABLE M1507.4 ON SHEET TS1 FOR CFM REQUIREMENTS �k~ � <br /> CD/SD _ <br /> EXISTING UNfT 2 NOTES: EDI LINARDIC <br /> EXISTING UNIT 5 1-BED UNIT 541 SF 1. SEE WHOLE HOUSE VENTILATION USING EXHAUST FANS SECTIONS ON SHEET TS1 <br /> 1-BED UNIT 446 SF <br /> STATE OF WASHINGTON <br /> � �` <br /> „ PROPOSED FLOOR PLAN FLOOR 2 � ' i � <br /> - - � � 2 HR FIRE RATED WALL SEE DTL <br /> � ) <br /> EXISTING WALL TO BE 1-HR FIRE ( � 10/A402 1/4"= 1'-0" <br /> RATED. SEE 10/A402 ___� �CD/SD O 7v �„� <br /> F � L <br /> EXIST. EGRESS WINDOW, \ 1 HR. FIRE � EXIST. WINDOW � N <br /> CONTRACTOR TO VFY. � RATED � � TO BE REMOVED � W M <br /> � 24'-2" J <br /> EXIST. WINDOW 1 T EXIST. WINDOW � �� , � �, � � � �� � � � <br /> TO BE REMOVED � � TO BE REMOVED RF 5-0 4'-0' 6-31l2 4-0' 4-101/2 "'1 <br /> .� � � <br /> II m � O <br /> -. ♦ J N . <br /> N .. ♦ � , w O O >` o0 <br /> � — <br /> � � - <br /> � � O W/D , „ � � <br /> N 6'-51/2" 2'_6° 2'-6" 6'-51/2" j O O M 10-11 � � . <br /> M / <br /> ` �UNIT 3 c� 50 cfm gATH 50 cfm 50 cfm � `'� B DROOM � � <br /> LIVING/DINING - 644 SF � BATH � LIVING �' � M <br /> � S1 HR FIRE /—� � _ � w — W <br /> � CO � RATING CEILING) o � W�„{ �O cv cv O�� \� o � o EGRESS OPNG. � J J <br /> EGRESS � THIS UNIT �,;� �`�/ � _ ___ ___ _ ___ � �WH � �;, o SILL MIN.44" o ao z O <br /> c•� O ( � cv �� O A.F.F. TYP. � �'' a � '� <br /> � O �CD/SD EGRESS � � <br /> o � v t <br /> 9'-11l2" 2'-10" 9'-41/2" � 3'-7" � 5'-1" q 7'-2" 3'-6" 2'-11° 2'-11" M 11'-0" 6'-4" 5'_�" o � <br /> ; � <br /> N � �V1//D � � O � N 3 ° n � Q W <br /> JI M O � <br /> � I � 50 c � U UNIT 4 O o p N � <br /> °r � O 660 SF CLOSET � a O � <br /> � � cWn I o �-- •-- v � (1 HR FIRE N ------ —� � N <br /> _ CD/SD � � I O � i i RATING CEILING) I z � �•} W <br /> w V �� U � � ( T H I S U N I T � Z � <br /> - I N o 1 <br /> � 2-HR FIRE RATED WALL I � � � p i � OUTLINE OF � <br /> �, -------1-� 3'-6" 3'-8" 2'-0" � 5'-6" 11'-0" D SD 6'-6�� '�` FLOOR ABOVE w � W <br /> BETWEEN UNIT AND RF I w <br /> STAIR SHAFT,TYP. SEE � � � � DINING o I � <br /> DET. 4/A402 � � 4 � � � � 2 HR FIRE RATED WALL <br /> � '' � O � � � c� ( (——I 4 TYP SEE DTL 4/A4i 2 0 � <br /> � �, I----- � <br /> � � I ( UP ��_ <br /> � ----1 I U 100 � _____ � � �H 3 i � RF A402 i DESIGNER: LUIS MARTINEZ ' <br /> /-- ----T----- — --�— -�� �� s - <br /> � _� � I � KITCHEN <br /> I t- o � M ,-qr, PORCH � o <br /> I � - � � I � 0 c m � � ENGINEER: WADE DAMEY <br /> � 3�'��� � ;' ——— — — — _ � _ <br /> I UP o � �, � _� A C� O 'N ----O SAFETY � Z <br /> - i � <br /> � <br /> I ( � `V � �� � �� „ , „ GLASS I � � PROJECT NAME: APARTMENT BLDG.ADD'N. <br /> � 4-6 � _ 11-5" 4-2 5-0 � 17'-10 5-10 � v PERMiT STAMP HERE(2 1/2"x 2") � <br /> I � ------------- - --- I = � <br /> � O ( � COMMON SPACE O DN � N <br /> � � pN � � SEE A501 520 SF (2 HR FIRE SAFETY H I M � PROJECT NO.: 160001 <br /> M �,; RATING CEILING) p � <br /> i � o FOR STAIRS#1 GLASS 3 I � <br /> 3 (cr�. COMMON AREA Oq w <br /> � o a DATE: 01.19.16 <br /> , - <br /> . � � <br /> � � --------------------- _ -------� � ��OO � �� � �, ' � � I SHEETNO.: <br /> • � 2$r8�/�— 4-0 25-3 4-0 2-0' Q <br /> ``' SEE A502 � `" <br /> � ------- ----� 1- <br /> FOR STAIRS#2 -� 63'-11 1/2" 5'-0" w <br /> o � <br /> 68'-11 1/2" PROPERTY LINE � <br /> a <br /> t--- ---� <br />