Laserfiche WebLink
EXISTING UNIT 7 _ <br /> 1-BED UNIT 695 SF <br /> �s ,�, <br /> '`� � �,� .�,. <br /> ��� � �� <br /> u ►=- � '�'' `�� <br /> � ���� �.� � � : ; <br /> � � ��- <br /> � � � � <br /> �. ,,;. <br /> -� � ---� '"� <br /> � , <br /> O <br /> O � 0 RF <br /> � ODo <br /> EXIST. STORAGE <br /> 23 SF <br /> EXIST. STORAGE WALL TYPE LEGEND <br /> 58 SF <br /> ti � ti � rn � <br /> TYPICAL NEW EXTERIOR WA�L � � `- `- � `- <br /> EXTERIOR WALL SIDING o/(2)LAYERS 60#BLDG. PAPER o/ 1/2" p N N N °' N <br /> OSB SHEATHING o/2x6 WOOD STUDS AT 16"oc w/5/8"GYPSUM o o � o o ' <br /> WALL BOARD AT INTERIOR. PROVIDE R-21 BATT INSULATION. <br /> EXISTING 0 O � � � � <br /> TYPICAL NEW INTERIOR WALL <br /> COMMON SPACE <br /> (U.N.O.)ALL INTERIOR WALLS SHALL BE 2x4 WOOD STUDS OR <br /> z <br /> 261 SF 2x6 (WHERE PLUMBING REQUIRED)WOOD STUDS @ 16"oc w/ � � � � <br /> 5!8"GYPSUM WALL BOARD EACH SIDE. O O O O <br /> j U U U U <br /> TYPICAL NEW INTERIOR OR EXTERIOR EXISTING WALL O <br /> EXIST. � 2x4 OR 2x6 WOOD STUDS @ 16"oc INTERIOR OR EXTERIOR. a w w w w <br /> STOR. � � � � � cn � . <br /> O � 17 SF --------- TYPICAL DEMOLITION WALL � Q Q Q Q O r <br /> EXfSTING UNIT 6 O � O�O o p p p p W <br /> --------- WALLS TO BE DEMOLISHED. <br /> 1-BED UNIT 519 SF <br /> �� > . <br /> TYPICAL CONCRETE WALL <br /> CONCRETE WALL SPECIFIED BY STRUCT. ENGINEER z z z z � <br /> w <br /> • W o 0 0 o z <br /> EXIST. NDRY m m m m O <br /> D 37 SF <br /> EXISTING UNIT 8 O <br /> 1-BED UNIT 415 SF Z a a a a a <br /> SYMBOLS > <br /> w <br /> � <br /> �p HARDWIRED INNER CONNECTED SMOKE DETECTOR <br /> WITH BATTERY BACKUP. <br /> �CD/SD HARDWIRED INNER CONNECTED CARBON MONOXIDE/SMOKE DETECTOR <br /> RF COMBO WITH BATTERY BACKUP. <br /> � � � WHOLE HOUSE VENTILATION FAN � <br /> � WHV PER TABLE M1507.3.3(1) <br /> O 4423 <br /> � � � EXHAUST FAN ' REGISTERED <br /> I I EXISTING EGRESS SEE TABLE M1507.4 ON SHEET TS1 FOR CFM REQUIREMENTS ' ARCHIT,�CTS ', <br /> �-1 WINDOW, CONTRACTOR <br /> � � �,{�� <br /> TO VFY. NOTES: <br /> 1. SEE WHOLE HOUSE VENTILATION USING EXHAUST FANS SECTIONS ON SHEET TS1 ��� '` ` � <br /> �CD/SD ` EDI LINARDIC ' <br /> ( � ��STATE OF WASHINGTON <br /> � � n <br /> , . <br /> WALL AN <br /> D DOOR <br /> �� �� I � <br /> TO BE REMOVED � (� ', <br /> EXISTINGWALLTOBE1-HRFIRE � �� � � PROPOSED FLOOR PLAN FLOOR 3 �❑ <br /> RATED. SEE 10/A402 ��y � <br /> EXISTING UNIT 9 � � 2 HR FIRE RATED WALL SEE DTL 1/4"= 1'-0" � n <br /> STUDIO 535 SF 10/A402 �.J <br /> Z �' <br /> - N <br /> 24'-2" � � � <br /> INFILL EXISTING INFIL� EXISTING 'J � N <br /> WINDOW RF WINDOW 5'-0" 4'-0" 6'-31l2" 4'-0" 4'-101/2" � T . <br /> � m Z M <br /> >- W � : <br /> N ♦ ♦ o � ♦ ♦ � w O - � O -� � N <br /> � E ; - 00 <br /> N � O W�D � ��i�; N I � O EGRESS � I � $��9 0 �j T <br /> -' � E � ` � V J <br /> M o O O M ' U M I J O � - <br /> r� 50 cfm BATH ( o I <br /> M U � � <br /> �0 cfm BATH �0 cfm � <br /> N D I N I N G 2'-11" 6'-5 1/2" 2'-6" 2'-6" 6'-5 1/2" 3'-4" `- "' 1 � <br /> O — \ � J � <br /> � LIVING � � � 1 N N o o ( H � °° Oq > I,.._ <br /> O � � WH � — - ';i,,, - - - F , H � - EGRESS OPNG. W � <br /> A `� \`� `O �I 4P,p� �II,''', ' ;w �� � "' � � �� SILL MIN.44" EGRESS o Z � <br /> J O w <br /> O ( II, �a'�' O N � � M o A.F.F. TYP. � a � . <br /> EGRESS N ' <br /> � �9'-1 1/2" 2'-10" 9'-41/2" : 3'-7„ 5'_g„ I g�_g° I 9,�„ _ ; 9,_6„ 3'-01/2" � /D 2 4112" 4'-0° 2'-5" o <br /> o � v � <br /> N � <br /> U N I T 5 ( � o � 4'-6" 4'-6" o ` , <br /> 644 S F � � N p � � W <br /> � 1 H R RE � I 3'-0" 6" 3'-0" �� � o � N <br /> �; , �, <br /> _ � � RATING� C----�) I � � � PONY WALL, g� , , ,� � � (� � � � <br /> O N <br /> _, w I � e�s� �;�-v � � HIGH TYP. _ � _ � �— W <br /> � � � C d" ( 2-HR FIRE RATED WALL � 50 cfm � z � <br /> THIS UNIT �1.�, r , �,,.r �j��r�; � <br /> - O ��Mr '� � � <br /> p � � � „ ,.,, <br /> N -i � � � BETWEEN UNIT AND Y �, Y � � � <br /> o V � I � STAIR SHAFT, TYP. SEE�CD/SD O° O � � N o � � <br /> 2-HR FIRE RATED WALL DET.4/A402 �„ ❑ � <br /> � � �: <br /> N — ___ <br /> BETWEEN UNIT AND RF -�i I 2��„ � � STUDIO � O w <br /> STAIR SHAFT, TYP. SEE I � � � ( ' � a' UNIT 6 _ � BA - o � <br /> DET.4/A402 �� KITCHEN o � I ' � 433 SF '� O � <br /> N � o �� � � q � UP DN I------ (1 HR FIRE � � t 2 6 <br /> � "' � O I 0 O � � I � � � � RATING CEILING) � 1 c <br /> �' (v 1 0 0 � � I I 8'-6" � I � T H I S U N I T � . <br /> -- ------ ---- -- <br /> -- � � � DESIGNER: LUIS MARTINEZ <br /> � r -�-� � - � � � � � � � <br /> � o I o I 5�_5�� 6,��� <br /> � �----_.�._ _. I � � `� � 1� - <br /> N � 1 <br /> ENGINEER: WADE DAMEY <br /> � o DN � �� � �` I ( � � "? W/D � STUDIO _ <br /> , <br /> E _0 �� � <br /> 7 <br /> �`� � � ` �1 ' � N - -----�t'JfdIT 7 2'-4" z <br /> I �J I_ ���;� I — — — N - <br /> � Y' ����_ ��L�li N <br /> �) i��'�-�." }�i��/S�31�x�? n�r.,r J � 3� N � � <br /> PROJECT NAME: APARTMENT BLDG.ADD'N. <br /> � OO I A ����` P1�5 ���' ��- '�� COMMON AREA 1 HF� FIRE � PERMIT STAMP HERE(2 1/2"x 2") � <br /> 14x24 PICTURE 3_0 N �' ����V„�g7-� �� ��'� " - N - ---� SEE A501 RATING CEILING o <br /> � � �� UP I �T'b ----- <br /> WINDOW o � ti � FOR STAIRS#1 467 SF w/ � THI UNIT �r, c W i� P R O J E C T N O.: 1 6 0 0 0 1 <br /> �.., 5'-0" 14'-7" °�°� '� � CE I�L NG E R A T E D ,I':\ I � . <br /> I � � O � 3� , RECEIVED W <br /> -----� a DATE: 01.19.16 <br /> _ <br /> O AUG 3 0 2019 = . <br /> � --------------------------� SHEETNO.: <br /> � 41'-8 1/2" 4'-0" 12'-3" 4'-0" 7'-0" CITY �F EVERETT ¢ <br /> SEE A502 PLANNING DEPT n <br /> FOR STAIRS#2 f- <br /> 68'-11 1/2" w <br /> o � <br /> � <br /> a <br />