Laserfiche WebLink
ATTIC VENT, SEE 2/A402 <br /> PRE-MANUFACTURED AT NORTH &SOUTH CONT. METAL RIDGE DRILL 2" DIA. HOLES @ 6"oc <br /> ROOF TRUSS EXT. WALLS ONLY VENT AS FOR VENTING OR AS 2x6 WOOD STUDS <br /> NORMAL BLOCKING w! RECOMMENDED BY RIDGE @ 16"oc 5/8"FIRE-SHIELD <br /> SHEATHING AT NORTH AND 12 VENT MFR. �2� 5�$„ 5 1/2"GLASS FIBER GYPSUM <br /> SOUTH WALLS ONLY <br /> VENTED BLOCKING 2"0 @ � ASPHALT SHINGLES OJ <br /> SOUNDBREAK NSULATION WALLBOARD ON 5/8" <br /> 6"oc EXCEPT AT NORTH 36"MIN. PLYWOOD SHEATH. SPECIFIED 5/8"SOUNDBREAK XP GYPSUM BOARD <br /> OR SOUTH EXTERIOR BY STRUCT. ENGINEER OI XP GYPSUM U DBREAK XP <br /> BOARD GYPSUM BOARD ON RC-1 <br /> WALLS ATTIC VENT AT NORTH AND SOUTH WALLS ONLY PRE-MANUFACTURED ROOF 5 1/2" GLASS FIBER <br /> TRUSSES RC-1 @ 24"oc <br /> ASPHALT HARDIE REVEAL PANEL INSULATION <br /> SHINGLES SIDING AT THIS WALL ONLY � � <br /> 30#FELT OR UNIT A UNIT B (2) 5/8"SOUNDBREAK �'`' �, <br /> XP GYPSUM BOARD � �. ` � � � . <br /> OTHER REQ'D. (� � 2x6 @ 16"oc PARAPET TOP &UNIT r ` \` <br /> UNDERLAYMENT �� BETWEEN UNITS STG57 �,�,,,_ ' � _ � �,).� <br /> �� �� OVER EXIST. BLDG. NGC 2010081 �� .�l ` � <br /> F <br /> ROOF SHEATH. � UL DESIGN: U305- 1 HR 19/32 PLY. F.F. OVER i� � � -'� <br /> PER STRUCT. 1� 'v OVER FRAMING, 15/32" INTERIOR �' ,'� ` '�'�'� <br /> �► � 1 SEE STRUCT. (2) 5/8" �- � <br /> II � � SOUNDBREAK PLYWOOD -�\ _� T., <br /> ��, � <br /> FRAMING, � XP GYPSUM 2x6 WOOD STUDS <br /> SEE STRUCT. BOARD @ 16"oc <br /> FLOOR JOISTS <br /> R49 BATT. � 5 1/2"GLASS FIBER PER STRUCT. <br /> INSULATION ATTIC VENT COR-A-VENT E INSULATION PROVIDE CONT. 2x �� <br /> 6.75 SQ-IN PER LFT � BLOCKING AS SHOWN TO <br /> � 5/8" FIRE-SHIELD CONTINUE FIRE RATING <br /> METAL FIBERGLASS AIR <br /> GUTTER/D.S. BAFFLE �_A�a ,� � 2�I�VENT PER GYPSUM WALLBOARD 5/8" FIREBLOC TYPE <br /> � ON 5/8"SOUNDBREAK STAIRS <br /> 1x8 TRIM SCREEN VENT 1„ � I I XP GYPSUM BOARD C WALLBOARD OR EXIT <br /> 3"CONT. UNIT A STAIRS OR EXIT <br /> PASSAGE <br /> PRE-FABRICATED WAY <br /> 2x10 TRIM TRUSSES w/R49 PASSAGEWAY <br /> R21 INSULATION 1'�S�OT INSULATION RC CHANNELS <br /> STC-53 <br /> @ 24"oc <br /> 1/2"T&G CEDAR NOTE: 5/8" FIREBLOCK TYPE � r� ►� � <br /> SOFFIT LAP SIDING REFER TO COR-A-VENT � NGC 2009014 C WALLBOARD ~ � ri v a; <br /> � BETWEEN UNIT AND GA FILE: WP4135-2 HOUR ¢ <br /> INSTALLATION INSTRUCTIONS „ STAIRS/EXIT UNIT � cN�i �Nci ti o <br /> 18"M,�,X. ATTIC VENT DETAIL 2x6@16 ocw/R21 � PASSAGEWAY o 0 0 � <br /> STAIR SHAFT/EXIT <br /> PASSAGEWAY WALL cr� c� c� v� <br /> 1� I 1� FIRE CONTINUITY z z z z , <br /> ROO F EAVE D ETAI L � 1 —H R AN D 2—H R F I RE BTWN. FLOORSw/ � � � � <br /> 1 „ _ . „ R O O F R I D G E V E N T D E TA I L � RAT E D WA L L S 2HR FLOOR/CEILING o 0 0 0 <br /> 1 1/2 - 1-0 2 4 SUPPORT <br /> �� _ � �� Z V U U U <br /> SUB FLOOR PER STRUCT. Rp o � � � � <br /> 1 1/2 1-0 PROVIDE CONT. e � 1 1/2" = 1'-0" a � � � � <br /> F- t- H H <br /> F.F. 1/2"MIN. P�ER PER SHEATHING v � � � � <br /> ADD BLOCKING FOR CONT. v� Q Q Q Q <br /> � FIRE RATING,THIS WALL SIDING PER ELEVS. - 2x6 BASE PLATE p w w w w <br /> 0 0 0 0 <br /> FLOOR JOIST FRAMING CONT. RIM JOIST 1/2" OSB PLYWOOD z z z z <br /> PER STRUCT SUBFLOOR <br /> 1 1/2" SILL SEAL AND � � � � <br /> (N) BUILDING RYPINSULATION, m m m m <br /> MIN. CONTINUOUS CIRCULAR CAPIILARY BREAK <br /> Z HANDRAIL w/1 1/4" OUTSIDE DIA. <br /> � SPRAY FOAM INSULATION JM MIN.AND NOT GREATER THAN 2" FLASHING � <br /> O <br /> 1/2"PROTECTION • a a a a <br /> CEILING C° CORBOND III OR SIMILAR Z <br /> � _ <br /> � BOARD, CONT. � FLOOR JOISTS PER W � <br /> ADD Zx6 w/R21 INSUL. STRUC. � <br /> 1-HOUR FIRE RATING AND SHEATH. WALL BTWN. LAP SIDING OR HARDIE CONCRETE <br /> (STC) CALCULATION 50 STC REQUIRED TWO LAYERS 5/8" FIREBLOC EXIST. TRUSSES FOR 1 HR REVEAL PANEL SIDING AT FOUNDATION WALL PRESSURE TREATED <br /> TYPE X WALLBOARD APPLIED FIRE RATED WALL. SEE THIS WALL d MUD SILL <br /> FC 5406 ASSEMBLY: 39 STC AT RIGHT ANGLES TO WOOD DTL. 4/A402 2-HR FIRE RATED WALL SEE DTL. SIDING PER ELEVS. - a INSULATION PER <br /> JOISTS. SCHED. <br /> 4/A402 ALL LEVELS THIS WALL p,T. 3/4" FURRING 4423 <br /> SPRAY FOAM INSULATION NOTE: REFER TO AMERICAN j'I f + � ' " I ' � ` � � <br /> JM CORBOND III OR SIMILAR: 36 STC � II I� II II I� II i t I I I I II I� II II I �I �V II II II �I � STRIPS @ 16"oc a a REGISTERED � <br /> TOTAL STC PROVIDED: 75 STC THUS OKAY. GYPSUM DESIGN No. FC 5406, i f TT7T � ARCH IT.ECTS <br /> SYSTEM FOR FURTHER 1-HR � <br /> RATING INFORMATION � " 5/8" GYPBOARD � ' � <br /> 19/32 PLYWOOD FINISHED FLOOR �,°O., WATER RESISTIVE FLASHING ° SHEATHING � ' <br /> OVER 15/32' INTERIOR PLYWOOD ' BARRIER, HARDIEWRAP �� <br /> REFER TO JM CORBOND III SPRAY <br /> � F•F• __ POLYURETHANE FOAM FOR STC � OR EQUIVALENT ' DAMPED � 4 CONC. 5LAB EDI LINARDIC I : <br /> SPECIFICATION COMPLIANCE PROOFING SLAB BASE (2" SAND) STATE OF WASHINGTON ' <br /> SPRAY FOAM INSUL. c�i <br /> JM CORBOND III OR RC CHANNELS STAIRS, SEE DETAIL 6/A401 FOR <br /> SIMILAR @ 24 oc RUN AND RtSE REQUIREMENTS �- <br /> (E) BUILDING � I-)I I= ° ° <br /> NOTE: REFER TO AMERICAN =I I I= ''y ' � ° <br /> . ..: . , <br /> � ::.. <br /> GYPSUM DESIGN No. FC 5724, FLOOR FRAMING PER I-I I ' -- - <br /> . - _--- <br /> Z SYSTEM FOR FURTHER 2-HR STRUCT. PLANS, SEE P E R F O R A T E D =I I I- °� <br /> � RATING INFORMATION EXIST. FLOOR 5/A402 FOR FIRE 4" PVC PIPE �i I I a I I I=I I I=I I I=I I�=I I I <br /> CONT. ��? `� -���-���-���-���-��� 4" GRAVEL BASE 3/8"- 3/4" <br /> CEILING C° MING ASSEMSLY SEPARATION 3 a , <br /> �--- REFER TO JM CORBOND III SPRAY a a I I I=I I I=I I I=I I I-)I( SCREENED WITH FINES <br /> POLYURETHANE FOAM FOR STC � FLOOR 4 ���I_� _ _ _ _ - _ _ _ = REMOVED (1� <br /> 5/8" FIREBLOC TYPE SPECIFICATION COMPLIANCE � -I I I-I � � <br /> -���-i i�-1 I I- <br /> C WALLBOARD -I I I- =1 I 1=1 I I-i�i-"'- COMPACTED SOIL <br /> CONT. CONCRETE � N <br /> 2-HOUR FIRE RATING Q <br /> F T G W M <br /> 1 & 2 HOU R FI RE RATED , � AT FULL HEIGHT EXTERIOR CONCRETE WALL J � N <br /> 0 � � <br /> FLOOR/CEILING ASSEMBLY HANDRAIL DETAIL HARDIEREVEALPANEL HEATED BASEMENT FDN DETAIL m z M <br /> 5 1 1/2" = 1'-0" � SIDING, TYP. THIS � W O <br /> 1 1/2"= 1'-0" WALL ONLY 3!4" = 1'-0" � N <br /> 5 " 5/8"GYPBOARD J � <br /> SHEATHING SHEATHING UNIT � � W <br /> 2x6 BASE PLATE PORCH JOISTS PER 2x6 BASE PLATE � FLOOR FRAMING PER �� V♦ <br /> SUB-FLOOR PER STRUCT. OR AS STRUCT. SUB-FLOOR PER STRUCT. OR AS STRUCT. PLANS, SEE LAP SIDING, TYP. — 'V` � <br /> INDICATED FOR FIRE RATING ON 5/A402 INDICATED FOR FIRE RATING ON 5/A402 ST. FLOOR 5/A402 FOR FIRE� � � <br /> RIM INSULATION, F ING ASSEMBLY SEPARATION 3 � M . <br /> `� � <br /> .�,P RIM INSULA ION, � FLOOR 3 � 1� �..� <br /> �- � <br /> SPRAY FOAM INSULATIO � O ^ <br /> . � <br /> . <br /> PROVIDE CONT. 2x � � � <br /> , . . <br /> BLOCKING AS SHOWN TO JM CORBOND III OR cn � <br /> SPRAY FOAM INSULATION � CONTINUE FIRE RATING SIMILAR FOR SOUND ¢ <br /> BETWEEN DWELLING UNITS, TYP. � I PROOF BETWEEN UNITS o <br /> FLOOR JOISTS PER O W <br /> (SEE 5/A402) STRUC. � � ? ONLY .� � <br /> F O J � EXTERIOR � ¢ ��/ <br /> STRUC. � � � LL <br /> R211NSULATION O N � <br /> ~ � V <br /> 1 NSULAT N 1 HR FIRE RATED � <br /> DAMPED DAMPED 5/8"GYPBOARD Z <br /> w '^ � <br /> 5/8"GYPBOARD SHEATHING WALL FLOOR JOISTS z ���� - <br /> PROOFING SHEATHING PROOFING <br /> �' PER STRUCT. � � <br /> � FLOOR FRAMING PER W � W <br /> PRESSURE TREATED R21 INSULATION w <br /> PRESSURE TREATED EXIST. FLOOR STRUCT. PLANS, SEE UNIT � <br /> R10 RIGID INSUL. MUD SILL R10 RIGID INSUL. MUD SILL 5/A402 FOR FIRE <br /> PER 1/A402 4" CONC. SLAB PER 1/A402 4"CONC. SLAB F MING ASSEMBLY SEPARATION � NO RC CHANNEL <br /> AT 1-HR EXTERIOR <br /> � Z SLAB BASE (2" SAND) SLAB BASE(2"SAND) a FLOOR 2 WALLS <br /> � �--- <br /> _ _ _ DESIGNER. LUIS MARTINEZ <br /> . <br /> �_��►� ° . . . �, ., -- a . 1 —H R F I R E RAT E D WA L L . <br /> — : . . . � . =_����►►= a <br /> .-. :. :_ . <br /> -I I I � ENGINEER: WADE DAMEY <br /> '—"' �—"' TRANSITION BTWN FLOORS � <br /> PERFORATED -I I I- °a i i -i i -i i i-i i i PERFORATED -I I I °a i i -i i-i i -i i i ■ <br /> 4" PVC PIPE �-�� a (��_���_���_���-��( 4" PVC PIPE �_�( a ���-���-�(�-��(_��� � <br /> __ _ _ _ , <br /> CONT. ���- `� _���_���_���_���_��� 4"GRAVEL BASE 3/8"- 3/4" CONT. ���- "d -��(_���-���-�(�-��� 4" GRAVEL BASE 3/8"- 3/4" ° 1 1/2"= 1'-0" z <br /> - ° a ° a I I I-I I I-I I I-I I I-I(I SCREENED WITH FINES —_� ° I I I=I I I-I I I-I I I-I I I SCREENED WITH FINES EXIST. CONCRETE 4 ' 2x4 16"oc w/R21 � PROJECT NAME: APARTMENT BLDG.ADD'N. ` <br /> i- i- ` � ° - °� PERMIT STAMP HERE(21/2"x 2") � <br /> -I I I-I I I-I I I=I I REMOVED -I I I-I I I-I I I-I I REMOVED WALL - I . INSULATION. 2"GAP o <br /> ��������i�-1 I 1=1 I I=I I I-I I I II I II I II I II I Ii i�I I I,-_,I I I I,--,�—li i�_I I 1=1 I I=I I I-I I I II I II I II I�I I Ii��I I I,-_,I I a BETwEEN 2x AND � <br /> COMPACTED SOIL COMPACTED SOIL ` CONCRETE WALL c"'n PROJECT NO.: 160001 <br /> CONT. CONCRETE CONT. CONCRETE �— g <br /> FOOTING FOOTING w <br /> � a DATE: 01.19.16 <br /> 1 —HOUR SEPARATION = <br /> Q SHEET NO.: <br /> HEATED BASEMENT FDN DETAIL HEATED BASEMENT FDN DETAIL BTWN EXIST. & NEW BUIDLING � <br /> � <br /> U <br /> 8 W <br /> � <br /> 3/4"= 1'-0" 3!4"= 1'-0" � O 3/4"= 1'-0" � <br /> a <br />