Laserfiche WebLink
a ' � ,. <br /> ,�, a;'M;� �`i��°�.cR�' � �d:. <br /> � '_ <br /> LEGEND <br /> ..� <br /> �_ ��;� <br /> Q q CEMENT CONCRETE SIDEWALK/ <br /> PAD PER DETAIL 326,SEE HS-02 <br /> Nelco Architecture, Inc, <br /> HMA PER DETAIL 326,SEE HS-02 <br /> a licensed affiliate of Nelson Worldwide, LLC <br /> � — — PROPERTY BOUNDARY LINE <br /> I CONSTRUGTION NOTES <br /> EXISTING PROPERTY INSTALL TYPE C CURB RAMP PER CITY OF EVERETT 7 200 Fifth Ave. Suite 1300 <br /> BOUNDARY LINE O STANDARD DETAIL 320, SHEET HS-02a SeattlB, WA 98101 <br /> EXISTING BANKING Phone: (206)223-4999 . <br /> CENTER i 2 INSTALL MONOLITHIC CEMENT CONCRETE SIDEWALK Fax: (206)223-4990 <br /> O PER CITY OF EVERETT STANDARD DETAIL 312,SHEET � <br /> 1.0' , � 6 HS-02. 5°/o MAX RUNNING SLOPE,2%MAX CROSS Client Representative: Architect: <br /> ~� o o Jones Lang LaSalle America's, Inc. Nelco Architecture Inc. <br /> � � �� SLOPE, SLOPES BETWEEN 5/o AND 8.3/o SHALL HAVE <br /> Nlaria Arsar�to Sen. PM: Ron pizarro <br /> N 330370.09 O HANDRAILS AND LANDINGS, FACE AND FIRST 6"OF TOP g00 Fifth Avenue, 16th Floor 1200 Fith Avenue, Suite 1300 <br /> ,a . $ 7 E 1303246.60 � 2 � OF CURB TO BE PAINTED YELLOW. MC: WA1-501-13-02 Seattle, WA 98101 <br /> d Seattle, WA 98104 Tel: 425.974.9072 <br /> � Tel: 206.773.4444 Email: rpizarro@nelsononline.com <br /> ( O INSTALL CEMENT CONCRETE CURB TYPE E-1 PER CITY <br /> � ° � � a � � � a a 3 OF EVERETT STANDARD PLAN 309, SHEET HS-02. Email: maria.arsanto@am.jil.com <br /> a _ a 4 . � - . _ 8 Job Captain: J. Scott Taylor <br /> �d . � _ � °a d ° . a � � . a Tel: 206.408.8523 <br /> � � d �' . � � d . � v � O ADA PARKING SPACE,ACCESS AISLE,AND STRIPING Email: JSTaylor@nelsononline.com <br /> 2 <br /> \ � 4 � . . � I a' 4 PER BANK STANDARD DETAIL,SEE DETAIL 4,SHEET <br /> ° � . a. a . a . ° � � .. a . 2 �� a . a . � o a a CURB HEIGHT VARIES, � HS-04.2%MAX SLOPE IN ANY DIRECTION, FULL LENGTH Architect of Record: Mark Evans <br /> � � a �. , a �a d a � . . , a a a . SEE GRADING PLAN Te1:z06.408.8519 <br /> . � _ � � a . . a a � a a a . a 4 � AND WIDTH. Email:mevans@nelsononline.com <br /> 4 " � 4 'Ql . � � °o°o°o o°o�o° <br /> 4 � . d 4' � . . ' • °o°o°o o°o°.o° <br /> m � a � � a � a � 4 � . °o°o°o o°o°o° ADA ACCESSIBLE PAVEMENT MARKING PER BANK <br /> °o°o°o o°o°0 5 General Contractor: Civil Engineer: <br /> _ � � . . . d Q . . � STANDARD DETAIL,SEE DETAIL 5, SHEET HS-04. Reliant Construction Inc. Parametrix <br /> a a a � 4 � Attn: Sonny Soumani Attn: Darren Sandeno <br /> I . . ° � : 5009 Pacific HWY East, Suite 7 1019 39th Avenue SE, Suite 100 <br /> ° 3 ( O INSTALL DETECTABLE WARNING SURFACE PER WSDOT <br /> � � ' I � � a• � a 6 STANDARD PLAN F-45.10-02,SHEET HS-03. Fife, WA 98424 Puyallup, WA 98374 <br /> � � j : a a � T: 253.355.8429 Te1: 253.604.6767 <br /> � ! � da . . � � a g Email: DSandeno@Parametrix.com <br /> '�`µ,----�.�� _ � ° . . a d v� � ACCESSIBLE WAYFINDING DIRECTIONAL SIGNAGE PER <br /> , - .__.______w _..,._�__} O <br /> ;..___ , . . . a . a <br /> _..______._.�_.__ � 7 <br /> , ; _� �_____�.�_______ a � ° � � . BANK STANDARD DETAIL,SEE DETAIL.S 1 AND 2,SHEET <br /> ' i . � v ° d a HS-04. CONTRACTOR TO VERIFY EXACT LOCATION IN <br /> � a Description: Noo By: Date: <br /> i o a ° � . a � I F1ELD. Issue for PJM Rev 1 CD/SN 07.03e18 <br /> i � a 4 a � a d . � . . <br /> d a a � . I $ CONTRACTOR TO FIELD VERIFY LEVEL LANDING,2% Issue for Permit 2 KB/SN 08.09.15 <br /> ! a . O <br /> ; 1 d . . a <br /> ° MAX IN ANY DIRECTION. <br /> � � � . d � . <br /> � : . 5 .a a . 5 a 9 GROUND MOUNTED VAN ACCESSIBLE ADA SIGN PER <br /> . °� � a � O BANK STANDARD DETAIL,SEE DETAIL 3, SHEET HS-04. <br /> � i � a a �� � <br /> ; i � . a � <br /> ; � 3 � GROUND MOUNTED ADA SIGN PER BANK STANDARD <br /> ; � Q ° <br /> Q Q 1 O DETAIL,SEE DETAIL 3,SHEET HS-04. <br /> a <br /> a <br /> I <br /> � <br /> GENERAL NOTES: <br /> 2.0' 8.0' 10.0' 8.0' 1.4' � 1. CONTRACTOR SHALL FURNISH AND INSTALL ALL <br /> MATERIALS AND EQUIPMENT NECESSARY TO <br /> COMPLETE THIS WORK. <br /> 2. CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS <br /> I AND GRADES. <br /> � <br /> I 3. CONTROL JOINTS ARE SHOWN FOR REFERENCE <br /> ONLY, CONTRACTOR TO PROVIDE ACTUAL CONTROL <br /> JOINT LOCATIONS AS NEEDED BASED UPON FIELD <br /> CONDITIONS. <br /> 4. CONTRACTOR TO PROVIDE TEST PANELS FOR EACH <br /> CONCRETE TYPE FOR REVIEW APPROVAL PRIOR TO <br /> INSTALLATION. � � <br /> 5. SEE GRADING PLAN FOR EXACT LOCATION OF SITE <br /> FEATURES TO BE INSTALLED. SILVER U-1KE ADA <br /> 1803 112TH ST SE <br /> EVERETT, WA <br /> NSRP VERSION : 2.0 <br /> BULLETIN : 1-2018 <br /> HARDSCAPE AND STRIPING PLARI <br /> ��`�� w����'L� <br /> � � � <br /> 47233 4� <br /> ��� '�I���w <br /> ��SI�NAI.E�C'1 <br /> / Z <br /> • � Proj. Noa 18.01816.00 Designer: CD <br /> Q Drawn By: CD Reviev�ed Bye SIV <br /> e SCALE IN FEET Project Managera DS Approved By: SN <br /> Know what's belOW. 0 5' 10' H S�� 1 <br /> C1II before you dig. <br /> NOTE. ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED <br /> SYMBOLS NOT TO SCALE ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS PRIOR TO <br /> PERFORMING THE WORK.THE PROJECT MANAGER SHALL BE NOTIFIED IN <br /> WRYTING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE�lVORK. <br /> Oc NELSON WORLDWIDE,LLC 2018 ALL RIGHTS RESERVED <br /> � <br />