Laserfiche WebLink
___ __ _____ _ __ _ _ <br /> — __ ___— 11 VIli!'Wl ____ --- -'-- — . _____ __ _ _ . <br /> _ _1— __ <br /> FINISH SCHEDULE GENERAL NOTE ;-�� �;; :�, <br /> 1. CONFLICTS BETWEEN SITE CONDITIONS AND DRAV�/INGS SHALL BE BROUGHT �s <br /> z� <br /> MARK DESCRIPTION TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. � �� y �-. � <br /> WM-1 MANUF: REESE ENTERPRISES, INC, <br /> 2. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQl1ARE AND � ? b'� <br /> TRUE AND IN PROPER ALIGNMENT, U.N.O. <br /> NAME: PERFEC MAT- RUBBER HINGED <br /> 3. ALL DIMENSIONS ARE TO FINISFi CONSTRUCTION, U,N.O. DIMENSIONS NOTED Nelco Architecture, IC1C, <br /> COLOR NAME; POLYPROPYLENE BRUSH - GRAY "HOLD" MUST BE ACCURa4TELY MAINTAINED, AND SHALL NOT VARY MORE <br /> FINISH: TREAD RAILS-ANODIZED ALUMINUM CLEAR, 2"VINYL EDGE, THAN t 1/8'°WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. "ALIGN" a licensed affiliate of Nelson Worldwide, LLC <br /> BLACK MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. <br /> DIMENSIONS NOTED "CLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE <br /> NOTES: TRIM VINYL EDGE AS REQUIRED, USE TS-1 TRANSITION TRIM MAINTAINED WITHOUT EXCEPTION. DIMENSIONS MARKED f MEAN A <br /> VARIANCE NOT GREATER THAN 1 INCH,VERIFY DIMENSIONS EXCEEDING <br /> TS-1 MANUF: PROVIDED BY GC TOLERANCE WITH THE ARCHITECT. ALL DIMENSIONS TO THE EXTERIOR <br /> NAME: CARPET TO CERAMIC TILE TRANSITION STRIP WINDOW WALL ARE TO THE FINISH FACE OF WALL BELOW SILL, u.N.o. 1200 Fifth Ave. Suite 1300 <br /> FINISH: SATIN SILVER 8. PARTITION DEPTH AT FIRE EXTINGUISFiER CABINET LOCATIONS SHALL Seattle, WA 98101 <br /> ACCOMMODATE FULL CONCEALMENT OF RECESSED CABINETS OR PARTIAL phone: (206) 223-4999 <br /> ATM NOTES: INSTALL PER MANUFACTURER'S INSTRUCTIONS CONCEALMENT OF SEMI-RECESSED CABINETS AS SPECIFIED BY THE Fax: (206) 223-4990 <br /> 103 MAN U FACTU RER. <br /> CH-27B MANUF: BERNHARDT DESIGN 11. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING <br /> TELLER MODEL: HELIUM 1712 CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTION. Client Representative: Architect: <br /> VAULT 102 12. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH ]ones Lang LaSalle Nelco Architecture Inc <br /> 105 FINISH: BERNHARDT 845 MAPLE WITH NO VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH, U.N.O. - REFER TO Eric Dockery 1200 Fifth Avenue, Suite 13D0 <br /> FABRIC: DESIGNTEX ALDER FOG MATERIAL SCHEDULE &FINISH PLAN FOR MATERIALS&LOCATIONS THAT 800 Fifth Ave. 16th Floor Seattle, WA 98101 ; <br /> REQUIRE A LEVEL 5 FINISH, U.N.O. Seattle, WA 98104 Project Contact: Ron Pizarro <br /> NOTES: PROVIDED AND INSTALLED BY BANK VENDOR Tel: 206.305.9779 Tel: (425) 974-9072 <br /> � 14. ALL NEW PARTITIONS ARE TO BE TYPE 1A U.N.O. REFER TO THE PARTITION eric.dockery@am.jll.com Email:rpizarro�alnelsononline.com <br /> w TYPES FOR PARTITION THICKNESS. <br /> = Architect of Record: Adam Segalla <br /> � 17. WHERE PARTITIONS EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING, Tel: (206)408-8510 <br /> o SECURE THE TOP TRACK TO THE EXPOSED CEILING GRID. PROVIDE A Email: asegalla@nelsononline.com <br /> � <br /> COMPRESSIBLE GASKET BETWEEN THE TOP TRACK AND THE CEILING GRID. AR License No: 10194 <br /> X PROVIDE TAPABLE METAL J-BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO <br /> o _ _ _ _ ]OINTS VARYING MORE THAN 1/8" OVER 6'-0"AND NO JOINTS GREATER THAN <br /> N — � 3/16 , U,N.O. CAULK PERIMETER AT TOP OF GWB. Civil Engineer: <br /> " Firm: Parametrix <br /> p ( 18. PROVIDE GFtOUNDS AND BLOCKING IN METAL STUD WALL FRAMING FOR Attn: Darren Sandeno <br /> o SUPPORT OF CASEWORK, SHELF-STANDARDS, A/V DEVICES, FURNITURE, ETC. T: (253) 604-6767 <br /> w CO PON � - � ALL CONCEALED LUMBER AND BLOCKING TO BE FIRE TREATED. COORDINATE ' <br /> m BO TH 106 E-mail: dsandeno@parametrix.com <br /> 102 z BLOCKING REQUIREMEIVTS WITH FURNITURE &AV INSTALLERS. WHERE <br /> � I 1 6 I � OFFICE � Q 1 BLOCKING OR ADDITIONAL STUDS ARE REQUIRED AT EXISTING PARTITIONS, <br /> � <br /> = E UPMENT 1 0 4 _ w THEY ARE TO BE PATCHED AND REPAIRED. <br /> � , „ , „ General Contractor: <br /> � I I z � v 6 -0 MIN. 6-0 MAX �� Firm Name: Reliant Construction <br /> Q 107 ,� CH-27B 101 `'r' CLEAR ALIGN WITH 19. ALL HINGED DOORS TO BE 4 FROM NEAREST PERPENDICULAR PARTITION, <br /> � — � U.N.O. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. ALL Attn: Sonny Saumani <br /> � 2 �� I N N REST GROUTLINE �ooRs sHa,�� HAVE i'-6" CLEAR ON THE STRIKE/PULL SIDE OF DOOR AND 1'-0 T: (253) 355-$429 <br /> L A-1-1 � I c� CLEAR ON THE STRIKE/PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A E-mail.ssaumani.reliant@outlook.com <br /> � FE 104 Z CLOSER) VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING <br /> m I I I i .�:. LOBBY � Q 101 OUT PARTITIONS. <br /> � I � 1 0 6 1 0 1 o J � 21. PROVIDE D OUBLE STUD S AT D O OR HEADER AND JAMB S. IN STALL ADDITI O N A L D e s c r i p t i o ne N o: B y: D a t e: <br /> � � _ _ � 1 _' V O � STUDS IN EXISTING PARTITIONS AT NEW DOOR OPENINGS IN ORDER TO <br /> m JANITOR I M � J PROVIDE DOUBLE STUDS. , P]M REVIEW MC 11/21/18 <br /> Q ' PERMIT SUBMISSION MC 11/27J18 <br /> � 108 � J ❑ � � �� � �2 WM-1 23, PROVIDE DIAGONAL STUD BRACING TO SLAB ABOVE @ 48" O.C. AT DROP PERMIT REVISIONS � MC O1/18/19 <br /> 6-O MIN. F— �j TS-1 ARCHES/BULKHEADS. <br /> � ios \, � CLEAR z � z � � <br /> � MEN U � w � H <br /> a 110 z OPEN OFFICE � V Q <br /> � � 107 � M CONSTRUCTION PLAN LEGEND <br /> a � 6'-0" MIN. <br /> o HOLD EXISTING WALL OR PARTITION TO REMAIN <br /> � <br /> � <br /> NEW PARTITION <br /> o � ' AREA NOT IN CONTRACT <br /> v __._. � <br /> •� "� � <br /> v <br /> o = _ �� ___.. <br /> . ;� _ . _� �� ��_.� e_ m __ � _ .�__ _mv __M . . <br /> � _ . , <br /> Q � � <br /> � <br /> � _ _. ._ �. ___ _ ___ _ 0 KEYNOTES <br /> m <br /> v 101 NEW QUEUE LINE STANCHIONS PROVIDED AND INSTALLED BY OTHERS <br /> � <br /> 3 WOMEN 102 MODIFY EXISTING TELLER LINE TO RECEIVE NEW GROMMET HOLE. <br /> � COORDINATE LOCATIONS WITH EXISTING QST EQUIPMENT. NEW <br /> � 111 GROMMETS MUST BE SET FLUSH INTO THE COUNTERTOP TO ALLOW FOR <br /> � � ' , PROPER INSTALLATION OF DEVICE. ATTACHE DEVISE WITH HIDDEN <br /> � ����, � VELCRO � <br /> 0 103 PATCH AND REPLACE CARPET TO MATCH EXISTING IN ROOM AT POINT <br /> �i 1 SHOWN ON PLAN AND BEYOND <br /> � � <br /> 104 RELOCATED CHAIR <br /> �i STORAGE <br /> J 112 1 <br /> fO � 105 RE-INSTALL EXISTING DOOR AND HARDWARE. ALTER SWING AS SHOWN � � � �,., <br /> ,.�. <br /> v �., IN PLANS. RE-USE HARDWARE AND NOTIFY ARCHITECT IF EXISTING �' " ' �"' �"��~': �'�"�� <br /> > <br /> � � HARDWARE IS CANNOT BE RE-USED. SUBMIT ANY ALTERNATES TO `�"' <br /> �� O' ,�° ARCHITECT FOR APPROVAL, FOLLOWING STANDARD SUBMITTAL <br /> � W PROCEDURES. NO DOOR CLOSER TO BE INSTALLED. SEE DOOR SCHEDULE <br /> � <br /> Q FOR ADDITIONAL REMARKS <br /> o�' ,d 106 RE-LOCATE EXISTING FIRE EXTINGUISHER. FINAL LOCATION TO BE <br /> / �'"""'_'"" <br /> � DIRECTED IN FIELD,AND AS APPROVED BY FINANCIAL CENTER MANAGER. <br /> d� <br /> �U� v, `�,�e <br /> M � �'t{ <br /> �`: <br /> u � PwTFORM '� ADA UPGRADES <br /> ¢ 115 <br /> ; sTORa � 1 SILVER LAKE <br /> � ii4 ,� �r WA4-138 <br /> � � � � � , _ <br /> � . �; �� � s}2�� {�Ip�; _ _ 1803 112TH STREET SE <br /> � BREAK � �� CLR. 105 EVERETT, WA 98208 <br /> J <br /> � � COUPON O <br /> � 113 \ <br /> > �'_��.._�, �� �� � _, 3 � BOOTH � I <br /> �.._ ,, <br /> � .: ` � ° '' . A-9-1 / � 106 �� <br /> � <br /> I <br /> Q �� � � � ATM � ��� � ' �� , � CONSTRUCTION PLAN �� <br /> m 116 I 104 / . <br /> o , 103 z / <br /> � � ,� <br /> � � � " ` I � <br /> _ J <br /> � � <br /> .--i <br /> o _— <br /> 0° "'" 1019�F <br /> . . . . .. . .. . . r ! <br /> � � ' � �- � f�EC�� TERED � <br /> � , <br /> � � �r �i <br /> � � AR;�N�7ECT�� <br /> �L <br /> � <br /> a 104 <br /> � AM '�G LL <br /> � STATE OF WASI;i�N�TON <br /> m <br /> o � � . <br /> L <br /> a � � � <br /> _ - v <br /> v <br /> � <br /> � <br /> z Pro No: 18.01816.00 Desi nere MC <br /> v NORTH NORTH �� g <br /> � 1 CONST'RUCTION PLAN 2 ENLARGED PLAN - FZM 106 Drawn Bye Reviewed By: AS <br /> a Project Manager; RP Approved Bye AS <br /> M Al-1 Scale: 1/4"=1'-0'" <br /> A - Scale: 1/2" = 1'-0'° <br /> � <br /> � A1 - <br /> 0 <br /> N <br /> � <br /> N <br /> � ALL DIMENSIONS AND COIVDITIONS MUST BE CHECKED AND VERIFIED <br /> � ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS PRIOR TO <br /> � PERFORMING THE WORK,THE PROJECI'MANAGER Sl1ALL BE NOTIFIED IN <br /> p • WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK� <br /> '-' c0 NELSOI�WORLDWIDE,LLC 2018 ALL RIGHTS RESERVED <br /> 0 <br /> a <br />