My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
430 SW EVERETT MALL WAY 2017 ENTERPRISE RENT A CAR Plans 2022-11-29 (2)
>
Address Records
>
SW EVERETT MALL WAY
>
430
>
ENTERPRISE RENT A CAR
>
Plans
>
430 SW EVERETT MALL WAY 2017 ENTERPRISE RENT A CAR Plans 2022-11-29 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 3:29:05 PM
Creation date
11/6/2019 9:21:54 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
430
Tenant Name
ENTERPRISE RENT A CAR
Permit
B1705-037
Year
2017
Notes
CONVERSION TO CAR WASH
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C405.2.3 Manual controls.Manual conirols for lights 5. Daylight responsive controls shall be configured • <br /> shall comply with the following: to completely shut off all controlled lights in that : <br /> 1. Sha11 be readily accessible to occupants. zone. : <br /> 2. Shall be located where the controlled lights are 6. Lights in sidelight daylight zones in accordance • <br /> visible,or shall identify the area served by the with Section C405.2.4.2 facing different cardinal : <br /> lights and indicate their status. orientations(i.e.,within 45 degrees of due north, : <br /> � C405.2.4 Daylight responsive controls.Daylight east,south,west)shall be controlled � <br /> : responsive controls complying with Section C405.2.4.1 independently of each other. . <br /> : shall be provided to control the lighting within daylight Exception:Up to two light fixtures in each � <br /> : zones in the following spaces: space are permitted to be controlled together � <br /> ■ with lighting in a daylight zone facing a . <br /> 1. Sidelight daylight zones as defined in Section ■ <br /> i different cardinal orientation. . <br /> . C405.2.4.2 with more than two general lighting ■ <br /> � fixtures within the primary and secondary 7• Incorporate time-delay circuits to prevent � <br /> : cycling of light level changes of less than tlu�ee . <br /> � sidelight daylight zones. minutes. : <br /> ■ 2. Toplight daylight zones as defined in Section ■ <br /> ■ 8. The maximum area a single daylight responsive ■ <br /> � C405.2.4.3 with more than two generallighting control device serves shall not exceed 2,500 : <br /> fixtures within the daylight zone. z . <br /> � square feet(232 m ). . <br /> Exception:Daylight responsive controls are not ■ <br /> : required for the followmg: 9. Occupant override capability of daylight � <br /> dimming controls is not permitted,other than a . <br /> 1. Spaces in health care facilities where patient reduction of light output from the level : <br /> care is directly provided. established by the daylighting controls. : <br /> 2. Dwelling units and sleeping units. ■ <br /> 3. Lighting that is required to have specific C405.2.4.1.1 Dimming.Daylight resporrsive : <br /> application control in accordance with Section controls shall be configured to automatically : <br /> C405.2.4. reduce the power ofgeneral lighting in the daylight � <br /> 4. Sidelight daylight zones on the first floor zone in response to available daylight,while . <br /> above grade in Group A-2 and Group M maintaining uniform illumination in the space : <br /> occupancies. through one of the following methods: : <br /> � 5. Daylight zones where the total proposed 1. Continuous dirnming using dimming � <br /> . lighting power density is less than 35 percent ballasts/dimming drivers and daylight-sensing . <br /> : of the lighting power allowance per Section automatic controls.The system shall reduce : <br /> : C405.4.2. lighting power continuously to less than 15 : <br /> � C405.2.4.1 Daylight responsive controls function. percent of rated power at maximum light � <br /> : Where required,daylight responsive controls shall be output. � <br /> : provided within each space for control of lights in 2. Stepped dimming using multi-level switching • <br /> : that space and shall comply with all of the following: and daylight-sensing controls.The system : <br /> ' 1. Lights in primary sidelight daylight zones shall shall provide a minimum of two steps of : <br /> � be controlled independently of lights in uniform illumination between 0 and 100 � <br /> : secondary sidelight daylight zones in accordance percent of rated power at maximum light � <br /> y with Section C405.2.4.2. output.Each step shall be in equal increments � <br /> � Exception: Spaces enclosed by walls or of power,plus or minus 10 percent. . <br /> ; ceiling height partitions with no more than General lighting within daylight zones in offices, � <br /> ; three general lighting fixtures may have classrooms,laboratories and library reading rooms . <br /> ; combined daylight zone control of primary shall use the continuous dimming method.Stepped � <br /> ; and secondary daylight zones provided dimming is not allowed as a method of daylight � <br /> � uniform illumination can be achieved. zone control in these spaces. � <br /> : 2. Lights in toplight daylight wnes in accordance C405.2.4.2 Sidelight daylight zone.The sidelight : <br /> : with Section C405.2.4.3 shall be controlled daylightzone is the floor area adjacent to vertical : <br /> ; independently of lights in sidelight daylight fenestration which complies with the following: : <br /> ; zones in accordance with Section C405.2.4.2. 1. Where the fenestration is located in a wall,the ■ <br /> . 3. Daylight responsive controls within each space sidelight daylight zone includes the primary : <br /> : shall be configured so that they can be calibrated and secondary daylight zones.The primary : <br /> : from within that space by authorized personnel. daylight zone shall extend laterally to the : <br /> � 4. Calibration mechanisms shall be readily nearest full height wall,or up to 1.0 times the : <br /> . <br /> . <br /> accessible. <br /> 2015 Washington State Energy Code CE-77 <br />
The URL can be used to link to this page
Your browser does not support the video tag.