,r��U� I
<br /> I •
<br /> � DOOR SCHEDULE WINDOW SCHEDULE KEY N OTES � � ,
<br /> N MBER LABEL TY FLOOR SIZE WIDTH HEIGHT THICKNESS COMMENTS NUMBER LABEL TY FLOOR SIZE WIDTH HEIGHT EGRESS TEMPERED U-FACTOR COMMENTS � �
<br /> DO1 5068 1 1 5068 R IN 60 " 80 " 1 3 8" WOl EX. 21 150DH 1 1 21 150DH 35 " 60" YES 0.3
<br /> D02 5068 1 1 5068 R IN 60" 80" 1 3 8" W02 EX. 2446DH 1 1 2446DH 28 " 54" 0.45 A� SMOKE DETECTOR W/ BATTERY BACKUP, HARDWIRED, INTERCONNECTED
<br /> D03 2668 1 1 2668 R I N 30 " 80" 1 3 8" W03 EX. 21050DH 1 1 21050DH 34" 60" 0.45
<br /> D04 2468 1 1 2468 R 28" 80 " 1 3 8" W04 EX.2020FX 1 1 2020FX 24" 24" 0.45 B❑ COMBINED SMOKE 8� CARBON MONOXIDE DETECTOR W/ BATfERY
<br /> D05 2868 1 1 2868 R IN 32" 80 " 1 3 8" W05 EX.6046FX 1 1 6046FX 72 " 54" 0.45
<br /> DO6 EX. 2668 1 1 2668 L IN 30" 80" 1 3 8" WO6 EX.2619FX 1 1 2619FX 30 " 21 " 0.45 BACKUP, HARDWIRED, INTERCONNECTED.
<br /> D07 EX. 41068 1 1 41068 L R 58 " 80" 1 3 8" W07 EX. 2619FX 1 1 2619FX 30" 21 " 0.45
<br /> C TEMPERED GLASS
<br /> D08 EX. 2668 1 1 2668 R IN 30" 80 " 1 3 8" W08 EX. 21030DH 1 1 21030DH 34 " 35 7 8 " 0.3 D EGRESS WINDOW
<br /> D09 EX. 2668 1 1 2668 R IN 30" 80" 1 3 8" W09 4050DH 1 1 4050DH 48 " 60" 0.3 ❑ Seattle
<br /> D10 EX. 4368 1 1 4368 51 " 80" W10 4050DH 1 1 4050DH 48" 60" 0.3 ED ADD 5/8"TYPE"X" GWB. TO ALL WALLS AND CEILING BELOW STAIRS
<br /> D 1 1 EX. 3068 1 1 3068 R EX 36 " 80 " 1 3 4" W 1 1 4050DH 1 1 4050DH 48 " 60 " YES YES 0.3 F� 1.5" HANDRAIL +34'� MIN-38" nnAx. Whidbey Island
<br /> Dl 2 EX. 9768 1 1 9768 L R EX 1 15 " 80" 1 3 4" W 12 4050DH 1 1 4050DH 48'; 60" YES YES 0.3 eG REMOVE EXISTING WALLS
<br /> D 13 3068 1 1 3068 R EX 36 " 80" 1 3 4" W 13 EX. 21043DH 1 2 21043DH 34" 51 " 0.3 H
<br /> D14 2668 1 1 2668 L IN 30' 80 " 1 3 8" W14 4040DH 1 1 4040DH 48 ' 48 ' YES 0.3 FO. Box 665 Freeland
<br /> D24 2618 1 0 2618 R EX 30" 20 " 1 3 4" CRAWL SPACE � EXHAUST FAN 90 CFM. MIN. VTO W/ 24 HR. TIMMER
<br /> D25 EX. 2468 1 1 2468 28 " 80" J NEW HOOD LOCATION, <40o CF�vt. vTo. Washington 98249
<br /> 206-283-8317
<br /> 360-341-1958
<br /> pagearch@whidbeyisland.com
<br /> www.williampagearchitects.com
<br /> NOTE: Issue/Revisions �
<br /> A MINIMUM OF 75% OF NEW PERMANENTLY INSTALLED LIGHTING
<br /> MUST BE HIGH-EFFICIENCY LAMPS PER WA ENERGY CODE No. Date Comments
<br /> R404.1
<br /> NORTH'_L'�VAiION
<br /> A
<br /> A2
<br /> A �\ A �`.
<br /> A13 i Al
<br /> �� 72'-1 1 1/4"
<br /> 2'-7 15/16'f I I
<br /> 18'-5" 14'-2" 10'-10" 3' � 14'-3" 9'-9" 12'-5 1/4" 7'-6" 1' 5'-3 1/4"
<br /> ' S�O
<br /> 10'-3" 3 l/2" OQ� 3 1/2"
<br /> � I Q�
<br /> � � _ _ _ _ _ __ _
<br /> P / L P / L P / L P / L P / � P / L P / L P / L P / L P / L P / L P / L P / L —�
<br /> �
<br /> � ,�
<br /> � _ . . . . . • • � , � ��
<br /> �Wo3; �wo/
<br /> . I � �wo>> �wo2> �. ,
<br /> �
<br /> __ __ . -
<br /> _ __ . __ _ co
<br /> ; W� N EP � � _ __ __ __ N
<br /> : � NEW
<br /> � � �-_� � EX.BATH ^' �
<br /> � LAUNDRY J
<br /> J ,',�-- — ---� I N 9'-1" X 6'-7° � -
<br /> a b Oo "' � : 50;� -- -- ; 'I ;5p10 7'_2� 1� n-
<br /> ' � �--------�--� �,,I ��
<br /> �. �
<br /> _
<br /> —J ,�___ ��
<br /> , --------------- ------------------------------- --
<br /> ; ��, �C2 — --� o EX. BEDROOM - '� ' D08 EX.BEDROOM D05
<br /> . . I i � 1� 11 1� 11 k - - ...
<br /> MA TER BATH D04 � 13 11 X 9 11 ` 12'-1" X 10'-11"
<br /> EX,GARAG E EX.STO R G E � �d'-2" x 7'-g" 0 = _ _ _. _ _ ��
<br /> , „ . „ . „ „ \
<br /> , y,o
<br /> .._ _, �... _._ _ __ _�_ �._� .��_ D11
<br /> 9 -8 X 21 -10 7 -8 X 15 -8 I D03 ��, ;�� DOb ��s� D09 �/\.ENT �,, ----� -----�----
<br /> J
<br /> � _ �` � J '\`�,� L I N. ; oo� t_ O _--___ ______._ �
<br /> ,,
<br /> � c:, \O � I � / � 7'-2" X 4'-6" os`�
<br /> N � MA TER BDRM TT TT Q Z
<br /> � � , „ , „ = I I I I I I I I - - - ,_. � Q�o B Q 3583 ��
<br /> Q _ 1 -8 X 14 -6 I u P - p,o _ ,� �
<br /> D14 E X. S 1 A I S I I I I I I I O
<br /> J A3 � � � � ; , �' A 2 L
<br /> � � .. _ Q
<br /> _ _ � - g ,
<br /> �
<br /> ,
<br /> N ___ _ __ �
<br /> so; -- �! t
<br /> ❑ N ..
<br /> 3 � �5� _ _,. D25 i i �— ' � J �,� � Rqi 1�_ �
<br /> : . � � I
<br /> I i
<br /> J • REMOVE EX. ' ` ' i � �
<br /> `__ _ __:__ _ �_
<br /> � ' '_ _ __. __ � I BEARING WALL ee � � �
<br /> � i ' :
<br /> � � I �SDi I ' �_ �
<br /> I
<br /> FAM i LY � �
<br /> � � 13'-s" x �4�-�0" EX. DINING EX.LIVING "'05
<br /> . ,_ „ ,_ ,� ,_ „ ,_ „ • � , _
<br /> � _ � � � ��� =����� � � � • EX.KITCHEN �2 o x �9 �o �s � x �4 0 _ _ • � – – � ' – – � ��-B � �
<br /> � �� � �� W,2�; W,,,> 14'-5" X 12'-2" � � a�3 �
<br /> � � �
<br /> � ` �
<br /> � � � � � � �
<br /> L . _ �n 5� 4'-6" ; ��s
<br /> (
<br /> _ __ ^ ; ' .
<br /> o �_.._ �
<br /> ee
<br /> � r � �
<br /> ,
<br /> � - -� ��- � �� � c� � _ _ FRIG _._.� �
<br /> �
<br /> _ ,
<br /> ;
<br /> __'_J i .i • '., - •
<br /> N • •I� �j .
<br /> �-
<br /> N
<br /> _�_ _ _._ _. _ _ ___ .
<br /> .._ .. ._ .. J
<br /> \ i ��� ��\ \
<br /> � � I � '\10� �W09i / OW 8� �W07j; � f �W\06, �
<br /> � ���,� �
<br /> � _ _ � .
<br /> _ _ . 6'-10" oi2
<br /> � 5 46 •
<br /> • _ . . . . . . . . . . . .
<br /> �
<br /> -; �
<br /> � - NEW DE K I EX. DECK �N � ��
<br /> � � 44'-10" X 10'-11" � �
<br /> I
<br /> I �
<br /> I
<br /> P / L - P / L P / L P / L P / L P / L P / L P / L P / L P / L
<br /> I Copyright 2018 William Page Architects
<br /> �
<br /> � 43'-1 1 1/4" Project
<br /> � �4 Lagoe-Rettenmier Residence
<br /> i 1816 Wetmore Ave. �
<br /> i
<br /> i
<br /> Everett, Washington 9820
<br /> I
<br /> Sheet Title
<br /> �
<br /> �
<br /> Plan Level 1
<br /> ^ Project No. 2018-16
<br /> � A � Date 06/23/2016
<br /> A3
<br /> Scale AS NOTED
<br /> SOUTH ELEVATION
<br /> Drawn By WJP
<br /> _ Checked By WJP •
<br /> I �I���f' �� �����?��`�
<br /> ���/I�.��,� ��� �����6�' North sheet ;
<br /> � lan Level 1 �
<br /> A-5
<br /> A Sc le 1/4" = 1'-0"
<br /> of Tota I S heets
<br />
|