My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3001 OAKES AVE 2017 Plans 2022-11-23
>
Address Records
>
OAKES AVE
>
3001
>
Plans
>
3001 OAKES AVE 2017 Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 2:09:44 PM
Creation date
11/6/2019 10:55:31 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3001
Permit
B1709-011
Year
2017
Notes
RESTORATION OF EXTG INTERIOR WALLS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,. .�. _. _ u ___ <br /> � _ _ <br /> G�fi�1��G I � <br /> �-3U I L.I� I 1�G , <br /> fi��STOfi��T I O�l <br /> 300 I O,��G�S �1��. <br /> �1���TT, Y�l,� �8201 <br /> U �► <br /> PANEL SCHEDULE:09/08/2017 PANEL 'P1 SECTION 1� PROJECT:Carnegie Building Restaration a r <br /> CLASSIFICATION:NORMAL VOLTAGE:208Y/120V 3RJ,4WIRE SECTION:1 OF 2 � <br /> FED FROM: MAINS:225A MLO+FEED-THRU LUGS � <br /> MOUNTING:FIELD VERIFY NEUTRAL:100%RATED O <br /> CKT BREAKER LOAD LOAD BREAKER CKT �..� <br /> NOT ITEM DESCRIPTION NO. AMP POIE (VA) fd (VA) AMP POLE NO. ITEM DESCRIPTION NOT r M"1 <br /> PEN AREA WORKSTATION RECEPTACLES 1 20 1 720 A 720 20 1 2 PEN AREA WORKSTATION RECEPTACLES v <br /> PEN AREA WORKSTATION RECEPTACLES 3 20 1 720 B 180 20 1 4 LOBBY WALL MOUNT SCREEN ^� <br /> OPEN AREA WORKSTATION RECEPTACLES 5 20 1 720 C 720 20 1 6 LOBBY RECEPTACLES/STORAGE � <br /> PEN AREA WORKSTATION RECEPTACLES 7 20 1 720 A 180 20 1 8 RAINING ROOM WALL MOUNT SCREEN � <br /> DE-ESCALATION CONTROLLED RECEPTACLES 9 20 1 180 B 500 20 1 10 REFRIGERATOR �� <br /> DE-ESCALATION RECEPTACLE 11 20 1 360 C 540 20 1 12 KITCHEN RECEPTACLES P1 <br /> RESTROOM RECEPTACLES 13 20 1 720 A 750 20 1 14 MICROWAVE ,��.�i+ � <br /> ' TRAINING ROOM 213 CONTROLLED RECEPTAC 15 20 1 540 B 720 20 1 16 FOYER/RECEPTION RECEPTACLES �'v <br /> TRAINING ROOM 213 RECEPTACLES 17 20 1 720 C 180 20 1 18 FOYER WALL MOUNT SCREEN � <br /> TRAINING ROOM 213 RECEPTACLES 19 20 1 900 A 540 20 1 20 FOYER/STORAGE RECEPTACLES <br /> TRAINING ROOM 213 WALL MOUNT SCREEN 21 20 1 180 B 360 20 1 22 COPIER ' <br /> IT ROOM RECEPTACLE 23 20 1 360 C 360 20 1 24 COPY ROOM 206 RECEPTACLES,EMPL. REST �8I3 IWG1�G.���1� l'�YL <br /> IT ROOM RECEPTACLE 27 20 1 360 B 540 20 1 28 TRAININGHROOM 203�OCON ROLLED RECEPTAC ���� � �v��� <br /> IT ROOM RECEPTACLE 29 20 1 360 C 540 20 1 30 TRAIN�NG ROOM 203 RECEPTACLES i,� <br /> IT ROOM RACK POWER 31 20 1 500 A 540 20 1 32 RAINING ROOM 203 RECEPTACLES P�f�� 4�������7 <br /> IT ROOM RACK POWER 33 20 1 500 B 20 1 34 �lV�: 425.31'i.VT�/�I <br /> 35 20 1 C 20 1 36 <br /> 37 20 1 A 20 1 38 <br /> 39 20 1 B 20 1 40 <br /> 41 20 1 C 20 1 42 <br /> LOAD CALCULATIONS CONNECTED LOAD-SEC.2:29,839 VA <br /> LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) H ,A R G I S <br /> MISCELLANEOUS CONTINUOUS: - 125% - LOAD SUMMARY <br /> EQUIPMENT&MISCELLANEOUS: 6028 100% 6028 mechanical 1201 third avenue,suite 600 • <br /> LIGHTING: 4601 125% 5751 TOTAL electrical <br /> LARGEST MOTOR: - 125% - CONNECTED LOAD AMPS telecommunications seattle,washington 98101 <br /> MOTdRS: - 100% - PHASE A: 15,988 VA 133 A �e�� t 20fi.448.3376 w hargis.biz <br /> R ECEPTAC LE: 10000 100% 10000 <br /> RECEPTACLES OVER 10kVA: 9800 50% 4900 PHASE B: 15,823 VA 132 A <br /> COM PUTER: 4600 100°� 4600 <br /> ELECTRIC HEATING: 9330 100% 9330 PHASE C: 14,518 VA 121 A <br /> KITCHEN(EQUIP=3): 1790 90% 1611 <br /> TOTAL CALCULATED LOAD: 42,220 VA <br /> TOTAL CALCULATED AMPS: 117 A <br /> TOTALS: 46,149 42,220 <br /> NOTES: HARGIS ENGINEERS,INC. <br /> 1. 1201 THIRD AVENUE,SUITE 600 '7. ST <br /> 2. SEATTLE,WA 98101 � ��� , <br /> 3. '�, <br /> 4. PH.(206)448-3376 <br /> 5. FAX.(206}44&4450 <br /> PEAK DEMAND CALCULATION WORKSHEET <br /> NEC 220-87 AND WAC 296-46B-900(3)(j) <br /> isl <br /> PANEL SCHEDULE:09/08/2017 PANEL 'P1 SECTION 2� PRWECT:Carnegie Building Restoratlon <br /> EXISTING MAIN SWITCHBOARD �` € �` <br /> CLASSIFICATION:NORMAL VOLTAGE:208Y/120V 3PJ,4-WIRE SEGTION:2 OF 2 ��,rl��l^�f 7 <br /> 1. RECORDED PEAK DEMAND = 32 KW FED FROM:PANEL'P1 SECTION 1' MAINS:225A MAIN LUGS ONLY f <br /> MOUNTING:FIELD VERIFY NEUTRAL:100°k RATED <br /> ON DATE: AUG/2017 <br /> CK7 BREAKER LOAD LOAD BREAKER CKT <br /> 2. POWER FACTOR / 0.850 (P.F.) NOT ITEM DESCRIPTION NO. AMP POLE (VA) fd (VA) AMP POLE NO. ITEM DESCRIPTION NOT . <br /> LIGHTING:UPPER LEVEL,SOUTH 1 20 1 681 A 675 20 1 2 LIGHTING:LOWER LEVEL,SOUTH <br /> APPARENT PEAK DEMAND = 37.65 KVA LIGHTING:UPPER LEVEL,CENTRAL 3 20 1 1320 B 715 20 1 4 LIGHTING:LOWER FLOOR,CENTRAL <br /> LIGHTING:UPPER LEVEL, NORTH 5 20 1 58Q C 630 20 1 6 LIGHTING:LOWER FLOOR,NORTH <br /> ROOFTOP RECEPTACLE 7 20 1 180 A 1650 20 1 8 ELECTRIC WATER HEATER <br /> 3. NEC 220-87 ADJUSTED PEAK DEMAND X 1.25 CABINET HEATER CUH-1 9 20 2 1392 B 900 20 1 10 MEETING ROOM 110 RECEPTACLES <br /> CABINET HEATER CUH-1 11 - - 1392 C 720 20 1 12 MEETING ROOM 110 RECEPTACLES � �ps� <br /> ADJUSTED PEAK DEMAND = 47.06 KVA EF-1 13 20 1 1440 A 720 20 1 14 INTERVIEW ROOM 112 RECEPTACLES �R�I��CT <br /> ABINET HEATER CUH-2 15 30 1 2004 B 720 20 1 16 INTERVIEW ROOM 113 RECEPTACLES <br /> 4. SEASONAL ADJUSTMENT FACTOR * X 1.00 ABINET HEATER CUH-2 17 30 1 2004 C 720 20 1 18 INTERVIEW ROOM 114 RECEPTACLES <br /> PEN OFFICE RECETPACLES 19 20 1 720 A 720 20 1 20 INTERVIEW ROOM 115 RECEPTACLES SAN�RA d. A�R <br /> SEASONALLY ADJUSTED PEAK DEMAND = 47.06 KVA PEN OFFICE RECEPTACLES 21 20 1 720 B 720 20 1 22 RECEPTION RECEPTACLES lTAh a�1l�C10N <br /> LOCKER ROOM,RISER ROOM RECETPACLES 23 20 1 720 C 720 20 1 24 INTERVIEW ROOM 116 RECEPTACLES , <br /> 5. OCCUPANCY ADJUSTMENT FACTOR * X 1.00 JANITOR CLOSET, RESTROOM RECEPTACLES 25 20 1 540 A 180 20 1 26 DA PUSHBUTTON DOOR CONTROLLER <br /> OPY ROOM RECEPTACIES 27 20 1 720 B 200 20 1 28 FIRE ALARM CONTROL PANEL <br /> OCCUPANCY ADJUSTED PEAK DEMAND = 47.06 KVA COPIER 2s zo 1 360 c �ss2 20 3 so HP-1 <br /> PARE 31 20 1 A 1632 - - 32 HP-1 <br /> SPARE 33 20 1 B 1632 - - 34 HP-1 �/�..�: � � <br /> 6. OTHER ADJUSTMENT FACTORS * X 1.00 SPARE 35 20 1 C 180 20 - 36 EXTERIOR RECEPTACLE I�7VL I�/'��: V:Nt•A/fVI� <br /> SPARE 37 20 1 A 20 1 38 SPARE <br /> ANNUAL PEAK DEMAND = 47.06 KVA SPACE 39 - - B - - 40 SPACE D���x: � <br /> SPACE 41 - - C - - 42 SPACE <br /> LOAD CALCULATIONS GHEGKEni UJ <br /> 7. NEW CALCULATED LOAD ADDED = 77.21 KVA LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) <br /> MISCELLANEOUS CONTWUOUS: - 125% - LOAD SUMMARY <br /> EQUIPMENT&MISCELLANEQUS: 5828 100% 5828 ���`g �"� � �" �� �� �� �A�� <br /> METERED DEMAND BASED LIGHTING: 4601 125% 5751 TOTAL Tf��C PROP�:'RTY OF` THL ARGHIT�liTS A�ND <br /> CALCULATED LOAD: 124.27 KVA LARGEST MOTOR: - 125% - CONNECTED LOAD AMPS I'�Y NOT B� �J�D YVIT�T PRIOR ' <br /> MOTORS: - 100% - PHASE A: 9,138 VA 76 A �i� ��� � /�l�i�"����T <br /> AMPERES AT 208V, 3-PHASE 344.94 AMPS RECEPTACLE: 9900 �oo�� ssoo <br /> RECEPTACLES OVER 10kVA: - 50% - PHASE B: 11,043 VA 92 A � <br /> ELECTRIC HEATING 9330 100% 9330 <br /> NOTE: SEE WAC 296-46B-901(15)Q) FOR ADDITIONAL METERING REQUIREMENTS. PHASEc: s,658VA aoa REVIEW <br /> * EXP�AIN HOW THE FACTOR WAS DERIVED FOR 30-DAY DEMAND METERING TOTAL CALCULATED LOAD: 30,809 VA �V. D�tTE DESGRIPTION <br /> TOTAI CALCULATED AMPS: 86 A <br /> SEASONAL- SEASONAL ADJUSTMENT IS NOT REQUIRED. Torn�s: 2s,659 so,8os 05/26 SGH�M�TIG I�516N <br /> NOTES: HARGIS ENGINEERS,INC. OB�Ir✓' PROCr7RESJ DR�WINCr7� <br /> OCCUPANCY - FACILITY IS ALWAYS OCCUPIED, THEREFORE NOT APPLICABLE. � �zo� THiR�AVENUE,suirE soo <br /> 2. SEATTLE,WA 98101 <br /> 3. <br /> OTHER - OTHER CORRECTION FACTORS ARE NOT APPLICABLE. 4� PH.�zos�aaa-33�s <br /> 5. FAX.(206)44&4450 <br /> LO/ 7L.� i..� Y �� <br /> �'OY�fiZ <br /> �1.00fi� i�L�l� " <br /> • <br />
The URL can be used to link to this page
Your browser does not support the video tag.