Laserfiche WebLink
�: <br /> -���i \ CARN EGI E � <br /> � � <br /> EXTERIOR WALL i i JACKET OR B U I L D I N G <br /> (CONCRETE, METAL OR , CARRIER PIPE <br /> WHERE PIPE IS <br /> WOOD ASSEMBLY) INSULATED R E S TO R A TI 0 N <br /> ��.� �� —CONCRETE + PIPE INSULATIO <br /> FLOOR 1/4" TO 1/2" MIN . <br /> RooA RooR GAP ` \ - . .\ \ .\ \ , , 3001 OAKES AVE. <br /> RISER CLAMP (TYP) PIPE THROUGH FLOOR ��� �� E VE R E TT, WA 9 8 2 01 <br /> ' WALL WALL P I PE <br /> CAULK PER ' <br /> SPECIFICATIONS ON PIPE fNSULATION CONCRETE, `-- - ; CONCRETE, CAULK PER � " � � � � � � � � " <br /> EACH END OF ��' � �� � <br /> (WHERE SPECIFIED) METAL OR WOOD � METAL OR WOOD SPECIFICATIONS ON EACH �\ \ \ \ <br /> SLEEVE. ' I� —ESCUTCHEON PLATE WHERE U <br /> ASSEMBLY WALL � ASSEMBLY WALL END OF SLEEVE. a <br /> \ 1/4" TO i� PIPE INSULATtON PIPING IS EXPOSED. � <br /> PIPE SLEEVE PER SPEC. � i 1/2" MIN � 1/4" TO 1/2" MIN (WHERE SPECIFIED) 1/4 TO 1/2 MIN PIPE SLEEVE PER <br /> EXTEND 1"ABOVE � , GAP ' �i ', WATERSTOP AND ANCHOR <br /> i GAP GAP SPECIFICATIONS. I � <br /> FLOOR (TYP). ' ' , COLLAR CONTINUOUSLY � <br /> � : •.--. ��' <br /> __. _ ___ ____ _ �' ------ ----- ,_ __ . • .__ GRADE WELDED ALL AROUND TO <br /> _ _ __ _ __ .. � . ` . � � <br /> , - �, �i i ;. � I� :, ' - � . � � � � � ,��� � _ � a�-- ' SLEEVE <br /> • •� : • � . ., � � � . � � � <br /> . <br /> '� <br /> a a a � � � � - i � <br /> . d . a � " . �, ; � <br /> � <br /> —� I i <br /> � ° � a � 1�4" T0�1/2"atilllN PIPE PIPE '��� � � i j� ° a � JACKET OR �---� <br /> a a , � : � a _ -� <br /> � �a ° i � � � � � � � � �P Tr � ,� <br /> o / � -- il— ii � <br /> ,� � ' � � � CARRIER PIPE CC� <br /> � , . � ` � . � � ' \ >. . � \ � ; WHERE PIPE IS r,.� <br /> � , __ _ °° ° — � _ � � � � . � � , � � , � FOOT NG WALOL R = , - <br /> - � , i � � <br /> ` �' ii � ' � � I �� � � _ � PIPE INSULATIO �NSULATED •� <br /> — � , -- � <br /> � � CAULK PER FIRE CAULK PER � � <br /> METAL DECK i i SPECIFICATIONS DIV. 07 PIPE SLEEVE r l <br /> �; � \ � � � � � � \ � . V <br /> �� �,c ! � ESCUTCHEON PLATE ON EACH END OF SPECIFlCATIONS <br /> PIPE INSULATION (WHERE SLEEVE. ON EACH END OF <br /> SPECIFIED) WHERE PIPING IS , ESCUTCHEON PLATE , SLEEVE. EARTH � P�PE 2813 ROCKEFELLER AVE <br /> EXPOSED (TYP) ON ONE OR BOTH <br /> ' PIPE SLEEVE PER � ' SIDES WHERE PIPING . '' � � � � � � � � EVERETT, WA 98201 <br /> __ — � � \ � � � � � � <br /> PIPE THROUGH FLOOR FIRE CAULK PER <br /> SPECIFICATIONS. � IS EXPOSED. PlPE SLEEVE PER PHONE: 425.'.S'I7.$O'I7 <br /> SPECIFICATIONS SPECIFICATIONS. <br /> ON EACH END OF EXPANDING FOAM = ESCUTCHEON PLATE WHERE <br /> SEALANT PER — —� � , � ' PIPING IS EXPOSED. FAX: 425.3�7.8489 <br /> SLEEVE. I ' i— I i— -, <br /> CEILING SPACE � ' CEILING SPACE � SPECIFICATIONS. _ , -� I i, �_'!� � �� d , 'LINK-SEAL' AS SPECIFIED <br /> � � , - I oa , . <br /> , I � <br /> � � � , I <br /> , ,_ � �_ <br /> NOTES: NOTES: <br /> 1. SLEEVE NOT REQUIRED IF WALL IS FRAMED. 1. SLEEVE NOT REQUIRED FOR EXISTING CONDITIONS. REFER TO SPECIFICATION. <br /> DETAIL — PIPE THROUGH EXTERIOR �R <br /> , DETAIL — PIPE SLEEVE THROUGH CONCRETE FLOOR 2 DETAIL — PIPE THROUGH INTERIOR WALL 3 FOUNDATION WALL <br /> M6.1 SCALE: NONE M6.1 SCALE: NONE M6.1 SCALE: NONE <br /> K� ��r <br /> TYPE 'ACR' HARD DRAWN � "'��► <br /> REFRIGERANT PIPING, SIZE � 't,�� <br /> PER MANUFACTURER'S � <br /> RECOMMENDATIONS � �. �`�'"� <br /> ; ,.: . � � - . <br /> � # <br /> 3l�Bil ,� <br /> ry ��;� � <br /> CONNECT TO FAN COIL �� 8� <br /> UNIT DRAIN <br /> �_m� .����� <br /> � <br /> CAP OR PLUG PIPE <br /> DEPENDING ON PIPE WATER SEAL TRAP <br /> MATERIAL. SEE NOTE 2 <br /> BREAK OUT FLOOR AROUND FOR INSTRUCTIONS <br /> EXISTING PIPE FOR MATERIAL TYPE. %4" CONDENSATE LINE PIPE FAN COIL UNIT (FCU) <br /> TO H.W. & C.W. TO THE NEAREST MOP SINK, <br /> EXISTING FLOOR PATCH FLOOR PER SUPPLY LAB SINK OR FUNNEL- <br /> ARCHITECT. RUNOUTS TO LAST FIXTURE SHALL ATER HAMMER ARRESTERS FLOOR DRAIN � �ps,�� ,,. <br /> - - - -- NOT BE SMALLER THAN SIZE �PROVIDE BEHI D ACCESS <br /> ,_ _ __ ARCHIIECT - <br /> , <br /> ' REQUIRED FOR ARRESTERS OOR IN WALL� <br /> ` <br /> � --- - - — - SLOPE y4"/ FT. SANDRA J. AI.DER <br /> �.. ._ __ _ � � <br /> i STA7E OF w11�i07�ON . <br /> �• _� __ __ __ _� i <br /> I,..--.'� , <br /> � <br /> EXISTING PIPE � SCALE: AS NOTED <br /> � TO FIXTURES � tP.�AST FIXT�URE � ISSUE DATE: 07�24�2017 <br /> NOTE: DRAWN: AC <br /> USE TAB�E 6-4 2045 UNIFORM PLUMBING CODE <br /> FOR FIXTURE UNITS. TOTALS USED FOR SIZING WATER CHECKED: RE <br /> HAMMER ARRESTERS <br /> NOTES: NOTES: (� THIS PLAN AND DE�GN IS AND REMAINS <br /> 1. COORDINATE EXACT PIPING CONNECTION LOCATIONS WITH THE APPROVED FCU SUBMITTALS. THE PROPERTY OF THE ARCHITECTS AND � <br /> 1. WHERE CONNECTION IS TO A DRAtN, REMOVE DRAIN BODY PRIOR TO CAPPING. MAY NOT BE USED WITHOUT PRIOR <br /> 2. CAPPING/PLUGGING INSTRUCTIONS PER MATERIAL: 2. PROVIDE CONDENSATE PUMP WITH UNIT WHERE SLOPE IS INSUFFICIENT TO ROUTE CONSENT FR�1 THE ARCHITECT <br /> CAST IRON NO HUB PIPING : INSTALL CAP AND NEW COUPLING. CONDENSATE PIPING TO THE NEAREST SINK OR FLOOR DRAIN. <br /> CAST IRON HUB AND SPIGOT PIPING : INSTALL PLUG IN EXISTING HUB AND CAULK OR <br /> GASKET ALL AROUND. <br /> COPPER PIPING : BRAZE CAP TO PIPE. REVIEW <br /> GALVANIZED PIPING : THREAD PIPE AND INSTALL CAP. <br /> REV. DATE DESCRIPTION <br /> 05 26 SCHEMATIC DESIGN <br /> 4 DETAIL — CAPPED PIPE 5 DIAGRAM — WATER HAMMER ARRESTOR 6 DETAIL — DX FAN COIL UNIT PIPING SCHEMATIC os ,5 PROGRESS DRAWINGS <br /> M6.1 SCALE: NONE M6.1 SCALE: NONE M6.1 SCALE: NONE <br /> 09 08 PERMIT SET - <br /> MECHANICAL DETAILS <br /> • <br />