GENERAL POWER ONE-LINE DIAGRAM FIRE ALARM SYSTEM TELECOMMUNICATIONS SYSTEM DRAWING INDEX G�i�N��G I � .
<br /> , WP �3U I 1..171 �1G
<br /> EXISTWG ELECTRICAL TO BE REMOVED SWITCHBOARD/SWITCHGEAR ------- EQUIPMENT ENCLOSURE F TELECOMMUNICATIONS DEVICE
<br /> � +��DEVICE SUBSCRIPTS (TYPICAL ALL SYSTEMS) E0.1 ELECTRICAL LEGEND & DRAWING INDEX ��STOi��T I Ol�l
<br /> (WP,WG OR OTHER SUBSCRIPT) (X=REPRESENTS THE#OF TELECOMMUNICATIONS MODULES) EO.2 ELECTRICAL NOTES &ABBREVIAT�ONS
<br /> EXISTING ELECTRICAL TO REMAIN �:=.� PANELBOARD, FLUSH-MOUNTED - BUS �(NON-STANDARD MOUNTING HEIGHT) (W=TELECOMMUNICATIONS WALL PHONE MTD AT+48"AFF)
<br /> (B=BLANK COVER PL.ATE) EO.3 ELECTRICAL SCHEDULES �OO( Ol'�T��S !� Y �.
<br /> NEW ELECTRICAL WORK -�--- PANELBOARD, SURFACE-MOUNTED WIRE FacP FIRE ALARM CONTROL PANEL (F=MODULAR FURNITURE DEVICE) ���fi��TT� 1'`1� �S2O I
<br /> �"' 0 Y �Ac=aBovE couNTER oEvicE� ED3.1 LOWER LEVEL POWER DEMO FLOOR PLAN
<br /> (S=SURFACE MOUNT)
<br /> --�--�- MATCHLINE OR PROPERTY LINE �--�FRONT) —0-- TERMINAL/ LUG Fa4P FIRE ALARM ANNUNCIATOR PANEL (WAP=WALL MOUNTED WIRELESSACCESS POINT DATA DEVICE) E2.OA LIGHTING CONTROL ZONE PLAN �
<br /> � TRANSFORMER � E2.1 LOWER LEVEL LIGHTING FL(30R PLAN �
<br /> ENLARGED PLAN BOUNDARY � MOTOR CONNECTION --�— CONNECTION OQ HORN/STROBE COMBINATION, WALL-MOUNTED ABOVE CEILING TELECOMMUNICATIONS DEVICE
<br /> �� �� ;—i (X=REPRESENTS THE#OF TELECOMMUNICATIONS MODULES) E2.2 UPPER LEVEL LIGHTING FLOOR PLAN U� ���
<br /> �, DISCONNECT SWITCH, NON-FUSED Q DELTA F HORN/STROBE COMBINATION, CEILING-MOUNTED �AP �WAP=WIRELESS ACCESS DEVICE) E3.1 LOWER LEVEL POWER FLOOR PLAN
<br /> ""�(SV=SECURITY VIDEO CAMERA) E3.2 UPPER LEVEL POWER FLOOR PLAN �
<br /> E1.1 DETAIL/PLAN IDENTIFIER � �
<br /> Q+ DISCONNECT SWITCH, FUSED `� WYE �c STROBE ONLY, WALL.-MOUNTED �� FIRE RESISTANT 3/4" PLYWOOD BACKBOARD E3.4 ROOF POWER PLAN Q
<br /> A E5.1 LOWER LEVEL FIRE ALARM FLOOR PLAN �
<br /> E1.1 SECTION IDENTIFIER 0+ ENCLOSED CIRCUIT BREAKER � CURRENT TRANSFORMER � STROBE ONLY, CEILING-MOUNTED e TWO-POST EQUIPMENT RACK �
<br /> E5.2 UPPER LEVEL FIRE ALARM FLOOR PLAN
<br /> �------� �
<br /> A VFD VARIABLE FREQUENCY DRIVE ; �o � �Q BEAM SMOKE DETECTOR - TRANSMITTER B 3.65" DOUBLE-SIDED VERTICAL MANAGEMENT E6.1 LOWER LEVEL LOW VOLTAGE FLOOR PLAN �
<br /> ELEVATION IDENTIFIER � ; � TRANSFER SWITCH � �
<br /> E�.� MANUAL MOTOR STARTER WITH THERMAL � � � E6.2 UPPER LEVEL LOW VOLTAGE FLOOR PLAN .,�
<br /> $M OVERLOADS ' ' QQ BEAM SMOKE DETECTOR- RECEIVER 8 6" DOUBLE-SIDED VERTICAL MANAGEMENT '
<br /> REVISION DEFINITION AREA, AREA ENCIRCLED L"—'-J E7.1 ELECTRICAL ENLARGED PLANS AND DETAILS �
<br /> CONTAINS CHANGES MADE SUBSEQUENT TO �+ COMBINATION STARTER/DISCONNECT n CIRCUIT BREAKER, FIXED 0 MANUAL PULL STATION 8 12" DOUBLE-SIDED VERTICAL MANAGEMENT E9.1 ELECTRICAL ONE-LINE DIAGRAM •
<br /> PREVIOUS ISSUE �
<br /> � MAGNETIC STARTER -{����- CIRCUIT BREAKER, DRAWOUT Os SMOKE DETECTOR � WALL MOUNTED ENCLOSURE E10.1 PANEL SCHEDULES
<br /> Q REVISION CALLOUT
<br /> 2813 ROGK:EFELL�R A�1�E
<br /> � EQUIPMENT CONNECTION - CONFIRM CONNECTION � DISCONNECT SWITCH QF�s FIRE/SMOKE DAMPER �� ?;:� FLOOR MOUNTED SERVER ENCLOSURE �1I�R�TT, YVI�'t �S�OI
<br /> � FLAG NOTE TAG WITH EQUIPMENT MANUFACTURER PHONE: 42r✓'.3I'7.SOI"�
<br /> �- FUSED SWITCH � HEAT DETECTOR � 110 BL.00K WITH LEGS F�C: 42�.3I.,�.S�FS�
<br /> O DEMOLITION NOTE TAG QF�s FIRE/SMOKE DAMPER
<br /> � FUSE Q MAGNETIC DOOR HOLD OPEN DEVICE a 66 BLOCK �
<br /> O EQUIPMENT TAG PUSHBUTTON CONTROLLER �
<br /> � (SINGLE OR MULTIPLE BUTTONS) �� CIRCUIT BREAKER WITH GROUND FAULT
<br /> GF x SWITCH DEVICE
<br /> � PROTECTION H J\ R G I S
<br /> AHU-01 MECHANICALEQUIPMENTTAG (F=F�owswiTCH>
<br /> � EMERGENCY POWER OFF PUSHBUTTON ST � CIRCUIT BREAKER WITH SHUNTTRIP OPERATOR cr=-raMPERsw�TCH> ACCESS CONTROL SYSTEM �
<br /> � � (P=PRESSURE SWITCH)
<br /> M ECHAN ICAL EQ U I PM ENT TAG mechanical 1201 third avenue,suite 500
<br /> AHU � electrical seattle,washington 9810i
<br /> GF O RELAY ACP ACCESS CONTROL PANEL te�ecommunicatior�s
<br /> security
<br /> RECEPTACLES FUSED SWITCH WITH GROUND FAULT PROTECTION energy t 206.44�.33�� w hargis.biz
<br /> N NORTH ARROW �s ----� DUCT SMOKE DETECTOR
<br /> CREDENTIAL/CARD READER
<br /> GF DEVICE SUBSCRIPTS f�1 (CR=CARD READER,WALL MOUNTED)
<br /> ,�� (CRlP=CARD READER W/PIN,WALL MOUNTED)
<br /> LOCATION WHERE PICTURE WAS TAKEN AND +42����(ac,�F,wP,i�,cR,TP,US6 OR OTHER SUBSCRIPT) � MOTOR CONNECTION � 10" EXTERIOR BELL -WEATHERPROOF CR (CRlM=CARD READER,nnu�uoN MourvrE��
<br /> O DIRECTION � �-(ciRcuir NUMBER> �
<br /> �-(NON-STANDARD MOUNTING HEIGHT) /(Gy GENERATOR Q KNOX BOX s� DOOR POSITION SWITCH
<br /> -� SPECIAL RECEPTACLE X METERING DEVICE NA� FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT pE DOOR ENTRY STATION, WALL MOUNTED
<br /> LIGHTING (M=nn�TER� POWER SUPPLY •
<br /> (WH=WATT HOUR METER)
<br /> � DUPLEX RECEPTACLE Ms DOOR MASTER STATION, DESK TOP s�
<br /> A (A=AMMETER)
<br /> (V=VOLTMETER) �� � �j
<br /> ��o RP IP SECURITY VIDEO SYSTEM ���,
<br /> DEVICE SUBSCRIPTS � FOU LEX RECEPTACLE SECURITY BUTTONS/SWITCH, WALL MOUNTED
<br /> 12ab (LIGHT FIXTURE TYPE) ST SHUNT TRIP [c�-�- VIDEO SECURITY CAMERA MOUNTING TYPES �� (AO=AUTO OPERATOR)
<br /> SPLIT WIRED DUPLEX RECEPTACLE (P=PENDANT MOUNTED) -1J (DR=DOOR RELEASE)
<br /> ��(CIRCUIT NUMBER/SWITCHLEG) � Y R=ROOF PARAPET MOUNTED) � (LD=IOCKDOWN)
<br /> GF GROUND FAULT PROTECTION �W=WALL MOUNTED W/BRACKET) (KS=KEYED SWITCH
<br /> o (��r�,�- DROP CORD RECEPTACLE O : (PB=PANIC/DURESS) �af
<br /> � "' w �
<br /> � LIGHTING FIXTURES EPM ELECTRONIC POWER METER LCJ �� VIDEO SECURITY CAMERA ID � �
<br /> � (REFER TO LIGHTING FIXTURE SCHEDULE #��(WHERE APPLICABLE REPRESENTS THE CAMERA#OR TYPE) SECURITY BUTTONS, UNDER DESK MOUNTED ��+� "����
<br /> '� (DR=DOOR RELEASE)
<br /> FORADDITIONAL INFORMATION) �CEWAYS AND BOXES SPD SURGE PROTECTIVE DEVICE ��o=�ocK�owtv�
<br /> O ❑ c�► CAMERA, CEILING MOUNTED �(PB=PANIC!DURESS)
<br /> � GROUND
<br /> 1--�� STRIP LIGHTWG FIXTURE Q JUNCTION BOX -�c -•- CAMERA, WALL MOUNTED -�--- REQUEST TO EXIT DETECTOR, WALL MOUNTED
<br /> 12,241 AVAILABLE FAULT CURRENT (SYMMETRICAL) TAG
<br /> Q�I F� WALL-MOUNTED LIGHTWG FIXTURE �F FURNITURE WALL FEED OUT�ET BOX CAMERA, WALL MOUNTED W/ BRACKET �--- REQUEST TO EXIT DETECTOR, CEILING MOUNTED
<br /> - 225 FEEDER TAG c �(180=180°VIEW CAMERA)
<br /> � PB PULL BOX x (360=360°VIEW CAMERA) � REQUEST TO EXIT, WTEGRAL MICRO SWITCH �D �as��
<br /> � �WHERE INDICATED,SUBSCRIPT INDICATES PULL BOX TYPE) r�---� ARCHITECT
<br /> i �
<br /> � HANDHOLE � � PAD MOUNT TRANSFORMER c 360° CAMERA, CEILING MOUNTED -� REQUEST TO EXIT BUTTON, WALL MOUNTED �
<br /> HH �WHERE INDICATED,SUBSCRIPT INDICATES UTILITY VAULT TYPE) ' O ' E T���
<br /> �� EMERGENCY LIGHTING FIXTURES � L�—__J
<br /> (REFER TO LIGHTING FIXTURE SCHEDULE UTILITY VAULT f"---� snn SECURITY MONITOR, WALL MOUNTED s O Q HORN, WALL MOUNTED
<br /> F O R A D D I T I O N A L I N F O R M A T I O N) � , � aaov �
<br /> • ■ �WHERE INDICATED,SUBSCRIPT INDICATES UTILITY VAULT TYPE) i I TRANSFORMER s� STROBE, WALL MOUNTED
<br /> XX
<br /> FLOORBOX (WHERE INDICATED,SUBSCRIPT INDICATES FLOOR � `� �Zpv i
<br /> � � �A BoxTYPE� L------� PERFORMANCE AUD10 VISUAL SYSTEMS � STROBE/HORN, CEILING MOUNTED 5G�41..�: �45 HO'Tfn
<br /> '.�` 155U� DA�'1�: 05/�6/201'i
<br /> POKE-THRU �WHERE INDICATED,SUBSCRIPT INDICATES � —I AUDIO VISUAL INPUT PLATE, WALL MOUNTED DOOR HARDWARE POWER SUPPLY (DIV 08)
<br /> � POLE-MOUNTED LIGHTING FIXTURE, QUANTITY OF Oq POKE-THRU TYPE) i i AV (5=DUAL HDMI&AUDIO) PS X (X=QUANTITY OF DOORS) D�N; �
<br /> HEADS AS INDICATED � � PANELBOARD - MAIN LUGS ONLY x�(6=HDMI,VGA&AUDIO}
<br /> m POWER POLE, FLOOR TO CEILING ; � -O AUDIO 3.5MM INPUT, WALL MOUNTED EL ELECTRIFIED HARDWARE GHEGK.�I7: DJ
<br /> �oQ DOUBLE HEAD, POLE-MOUNTED, LIGHTING FIXTURE �__� (EL=ELECTRIFIED LOCKSET/EXIT DEVICE) �
<br /> � SURFACE METAL RACEWAY (ES=ELECTRIFIED STRIKE) �T}{�g pLqN ANp D�.g�6N �5 /4ND REM�INv '
<br /> � � -O AUX AUDIO L/R XLR INPUT, WALL MOUNTED (ML=ELECTRIFIED MAGNETIC LOCK} ,� �TM � ,� A��,�,� �
<br /> �v� LIGHTING TRACK WITH FIXTURES RACEWAY CONCEALED IN WALL OR IN CEILING � � � (MH=ELECTRIFIED MAGNETIC HOLD OPEN) N1qY NOT 8� USED WITF�1T 1°RIOR
<br /> � SELF-CONTAINED BATTERY-POWERED EMERGENCY (EXPOSED IN UNFINISHED AREAS) � I � PANELBOARD - MAIN CIRCUIT BREAKER � MIC, AUX,AUDIO INPUT, WALL MOUNTED GONS�NT F'I�OM 1'� r4R�C.HIT�GT �
<br /> LIGHTING FIXTURE ------ RACEWAY RUN BELOW FLOOR OR BELOW GRADE ' �
<br /> I�--� sP SOUND WTERFACE PLATE, WALL MOUNTED
<br /> X (X=DENOTES CONFIGURATION TYPE) REVI EW
<br /> � EXIT SIGN, UNIVERSAL MOUNTING rww... FLEXIBLE RACEWAY TOUCH PANEL CONTROLLER, WALL MOUNTED
<br /> (SHADED AREA INDICATES D�RECTION ARROWS) TP X (X=DENOTES SCREEN SIZE)
<br /> __� RACEWAY (CIRCLE DENOTES VERTICAL GROUNDING RE1�. DA�TE DESGRIPTION
<br /> � EXIT SIGN, WALL-MOUNTED TRANSITION) Rv REMOTE VOLUME CONTROLLER, WALL MOUNTED
<br /> (SHADED AREA INDICATES OIRECTION ARROWS) —� RACEWAY CONTINUATION �I26 SGHEM,4TIG D�516N
<br /> —�— GROUNDING CONDUCTOR -� DUAL MICR4PHONE INPUT, WALL MOUNTED OS/I�✓ PROC�FZESr'.�' DRJ�4WINtr7�
<br /> OOCCUPANCY SENSOR, CEILING-MOUNTED ] RACEWAY STUB WITH BUSHING GROUND ROD
<br /> X WHERE INDICATED, SUBSCRIPT INDICATES TYPE Q O HANGING MICROPHONE, CEILING MOUNTED
<br /> . � OCCUPANCY SENSOR, WALL-MOUNTED [—] RACEWAY SLEEVE WITH BUSHING �--g GROUNDING BUSBAR Os SPEAKER, CEILING MOUNTED ,
<br /> Q PHOTOSENSOR � FIRE STOPPING SLEEVE � EQUIPMENT GROUNDWG CONNECTION s� LOUDSPEAKER, WALL MOUNTED
<br /> SWITCHES CABLE TRAY, 12"W x 4"H OVERHEAD, UNLESS � X (� _�2°,2-WAY LOUDSPEAKER)
<br /> OTHERWISE NOTED GROUNDING STRAP (2=�s",2-WAY LOUDSPEAKER)
<br /> (3= 15",3-WAY LOUDSPEAKER)
<br /> � SWITCH, SPST UON OR AS DEFINED BY SUBSCRIPT � CABLE TRAY, OVERHEAD LADDER TYPE �L.�GT�I G�L L�G�1�D
<br /> a=SWITCH LEG T=TIMER
<br /> 3=THREE-WAY MC=MOMENTARY CONTACT �
<br /> 4=FOUR-WAY P=PILOT LIGHT �.-.,,� HOMERUN TO PANEL �
<br /> K=KEYED LV=LOW VOLTAGE HA-3 QNDICATES PANEL DESIGNATION AND CIRCUIT NUMBER)
<br /> D=DIMMER OS=OCCUPANCY SENSOR
<br /> LVM=LOW VOLTAGE PROGRAMMABLE #�O `
<br /> �-(GAUGE OF WIRE OTHER THAN AWG#12)
<br /> (a,b,c) OR (a-c) CAN BE USED TO DESIGNATE �NUMBER OF CONDUCTORS
<br /> MULTIPLE SWITCHES. (�RouNo coNoucTOR�
<br /> (PHASE CONDUCTORS)
<br /> ANY COMBINATION OF SWITCH TYPES CAN BE USED (NEUTRAL CONDUCTOR)
<br /> (i.e. 3K = THREE-WAY KEYED SWITCH).
<br /> OT ALL SYMBOLS MAY APPEAR ON THE DRAWING �
<br />
|