Laserfiche WebLink
. ? , <br /> FASTENER NOTES <br /> ‘1,4111111.**1. <br /> "N. <br /> 1. ALL CONNECTORS SHALL BE APPROVED FOR USE WITH - - /---:----- ---:.---,7----71t--, -•'1.18 <br /> ACQ(or EQUIVALENT)PRESSURE TREATED LUMBER. <br /> CORROSIVE ENVIRONMENT FASTENERS <br /> 2. BOLTS,NUTS&WASHERS SHALL BE HOT DIPPED GALVANIZED PER ASTM A153 Daniel C.Smith,PE <br /> CLASS D. INSTALL BOLTS 2"MINIMUM FROM END. BOLT HOLES SHALL BE lAt." Consulting Engineers <br /> MAXIMUM LARGER THAN BOLT DIAMETER IN CORROSIVE AREAS,USE THE FOLLOWING 13237 Melvin Arnold Road <br /> SUBSTITUTION FOR FASTENER INDICATED IN DETAILS. 11,4!0.34,V.6C05207e6x1t31 <br /> 3. LAG SCREWS SHALL BE HOT DIPPED GALVANIZED,AND CONFORM TO ANSI/ASME <br /> STANDARD B18.2.1-1981- HOLE FOR THE THREADED PORTION SHALL HAVE A DETAIL SPECIFIES- SUBSTITUTE- F:877.841.6030 <br /> DIAMETER EQUAL TO 70%OF THE SHANK DIAMETER,AND A LENGTH EQUAL TO '., ....- F.declesdaristnitlipe.corn <br /> AT LEAST THE LENGTH OF THE THREADED PORTION.DO NOT INSTALL GRIP-RITE#9 x 1W"HOG NAILS GRIP-RITE#13 x 2"S.S.NAILS RESIDENTIAL <br /> THREADED PORTION OF SCREW BY DRIVING WITH A HAMMER. <br /> 4. ALL NAILS AND SCREWS IN CORROSIVE ENVIRONMENTS(e.g.,WITHIN 2 MILES OF GRIP-RITE#9 x 3"HOG NAILS GRIP-RITE#13 x 2"S.S.NAILS <br /> ATTACHED <br /> SALT WATER)SHALL BE STAINLESS STEEL. SEE SUBSTITUTION SCHEDULE — ,. <br /> GRIP-RITE#9 x 33/4"HDG NAILS GRIP-RITE#8 x 334'S.S.NAILS DECK <br /> 5. ALL NAILS SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153(UNO). HANGER <br /> NAILS SHALL PENETRATE WOOD 1W'MINIMUM. GRIP-RITE#10 x 4"HOG SCREWS GRIP-RITE#10 x 3"S.S.SCREWS -'' ' "'" ''''"' <br /> 6. ALL SCREWS SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153(UNO). <br /> CITY OF EVER ETT <br /> 7. LAG SCREWS(e.g.,LedgerLOKO)ARE NOT ALLOWABLE SUBSTITUTIONS FOR <br /> BOLTS PER CODE(TYP). REVIEWED FOR PERMIT <br /> CONNECTORS&EQUIVALENTS(USE SIZE SPECIFIED IN PLANS or LARGER) <br /> ....... _ _ <br /> SIMPSON <br /> SYMBOL PURPOSE USP# <br /> SUBSTITUTION <br /> —........* STRAP to secure GIRDER/EJ to FOOTING STI-TZ MA13152 <br /> 4x4 POST BASE PA44F.-TZ,PAU44-TZ ABA44Z,AB44Z • <br /> CD <br /> , g2g 1,4 4x6 POST BASE PA46E-TZ,PAU46-TZ ABA46Z,ABU46Z <br /> 6x6 POST BASE PA66E-TZ,PAU66-TZ ABA66Z,ABU66Z C) <br /> et 00 <br /> 1=3 <br /> A POST CAP for FLUSH GIRDER PB44-6TZ,PB66-6TZ LPC4Z,LPC6Z 60 ON <br /> 6 b' RAFTER TIE used to secure FJ to GIRDER — RT7A-TZ H2.5AZ <br /> J <br /> 1-PLY HANGER 1II526-TZ,JUS28-TZ, <br /> LUS26Z,LUS28Z,LUS210Z <br /> JUS210-TZ <br /> JUS26-2TZ,JUS28-2TZ, -.1.0 <br /> I L li — 2-PLY HANGER JUS210-2TZSC LUS26-2Z,LUS28-2Z,LUS210-2.Z ›,... .1.4 <br /> (1,) <br /> LI [1] 1-PLY INVERTED FLANGE HANGER 1L26IF-TZ,JL210IF-TZ I AJC/6Z,LUC210Z C..) <br /> ', <br /> , <br /> LU MI 2-PLY INVERTED FLANGE HANGER (2)1i26IE-TZ,(2)JL210TE-TZ ILUC28-2Z,HUC,210-2Z .4.-* x.-..4 i•- <br /> 1310:4rert ' <br /> 1 ‘... 1-PLY ADJUSTABLE SKEWED'ST HANGER , <br /> LSSH15-TZ LSU26Z <br /> DCSPE#: 18-D-0189 <br /> ADJUSTABLE L-ANGLE MP5-TZ,MP7-TZ,MP9-TZ I,S50Z,LS70Z,LS9OZ Drawn By: BML <br /> Revision History: <br /> u ragz:c ;) ADJUSTABLE STAIR STRINGER HANGER SH TZ LSCZ - - <br /> El FRAMING ANGLE for BLOCKING <br /> REINFORCEMENT A3-TZ GA2 X For Construction <br /> '''.' .;147r* c-,:'A4' e DECK TIE BACK w/ Not for Construc'on <br /> ---, <br /> .7 41 <br /> ..„, <br /> 'z'kk....,44, :', ' faH3 THREADED ROD&(8)SCREWS DTB-TZ DTT22 0, •'-iorf,,,..1 \-- . , Sheet. <br /> TENSION TIE for LEDGER REINFORCEMENT LTS19-TZ LTF19HDG N-3 <br />