|
. ? ,
<br /> FASTENER NOTES
<br /> ‘1,4111111.**1.
<br /> "N.
<br /> 1. ALL CONNECTORS SHALL BE APPROVED FOR USE WITH - - /---:----- ---:.---,7----71t--, -•'1.18
<br /> ACQ(or EQUIVALENT)PRESSURE TREATED LUMBER.
<br /> CORROSIVE ENVIRONMENT FASTENERS
<br /> 2. BOLTS,NUTS&WASHERS SHALL BE HOT DIPPED GALVANIZED PER ASTM A153 Daniel C.Smith,PE
<br /> CLASS D. INSTALL BOLTS 2"MINIMUM FROM END. BOLT HOLES SHALL BE lAt." Consulting Engineers
<br /> MAXIMUM LARGER THAN BOLT DIAMETER IN CORROSIVE AREAS,USE THE FOLLOWING 13237 Melvin Arnold Road
<br /> SUBSTITUTION FOR FASTENER INDICATED IN DETAILS. 11,4!0.34,V.6C05207e6x1t31
<br /> 3. LAG SCREWS SHALL BE HOT DIPPED GALVANIZED,AND CONFORM TO ANSI/ASME
<br /> STANDARD B18.2.1-1981- HOLE FOR THE THREADED PORTION SHALL HAVE A DETAIL SPECIFIES- SUBSTITUTE- F:877.841.6030
<br /> DIAMETER EQUAL TO 70%OF THE SHANK DIAMETER,AND A LENGTH EQUAL TO '., ....- F.declesdaristnitlipe.corn
<br /> AT LEAST THE LENGTH OF THE THREADED PORTION.DO NOT INSTALL GRIP-RITE#9 x 1W"HOG NAILS GRIP-RITE#13 x 2"S.S.NAILS RESIDENTIAL
<br /> THREADED PORTION OF SCREW BY DRIVING WITH A HAMMER.
<br /> 4. ALL NAILS AND SCREWS IN CORROSIVE ENVIRONMENTS(e.g.,WITHIN 2 MILES OF GRIP-RITE#9 x 3"HOG NAILS GRIP-RITE#13 x 2"S.S.NAILS
<br /> ATTACHED
<br /> SALT WATER)SHALL BE STAINLESS STEEL. SEE SUBSTITUTION SCHEDULE — ,.
<br /> GRIP-RITE#9 x 33/4"HDG NAILS GRIP-RITE#8 x 334'S.S.NAILS DECK
<br /> 5. ALL NAILS SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153(UNO). HANGER
<br /> NAILS SHALL PENETRATE WOOD 1W'MINIMUM. GRIP-RITE#10 x 4"HOG SCREWS GRIP-RITE#10 x 3"S.S.SCREWS -'' ' "'" ''''"'
<br /> 6. ALL SCREWS SHALL BE HOT-DIPPED GALVANIZED PER ASTM A153(UNO).
<br /> CITY OF EVER ETT
<br /> 7. LAG SCREWS(e.g.,LedgerLOKO)ARE NOT ALLOWABLE SUBSTITUTIONS FOR
<br /> BOLTS PER CODE(TYP). REVIEWED FOR PERMIT
<br /> CONNECTORS&EQUIVALENTS(USE SIZE SPECIFIED IN PLANS or LARGER)
<br /> ....... _ _
<br /> SIMPSON
<br /> SYMBOL PURPOSE USP#
<br /> SUBSTITUTION
<br /> —........* STRAP to secure GIRDER/EJ to FOOTING STI-TZ MA13152
<br /> 4x4 POST BASE PA44F.-TZ,PAU44-TZ ABA44Z,AB44Z •
<br /> CD
<br /> , g2g 1,4 4x6 POST BASE PA46E-TZ,PAU46-TZ ABA46Z,ABU46Z
<br /> 6x6 POST BASE PA66E-TZ,PAU66-TZ ABA66Z,ABU66Z C)
<br /> et 00
<br /> 1=3
<br /> A POST CAP for FLUSH GIRDER PB44-6TZ,PB66-6TZ LPC4Z,LPC6Z 60 ON
<br /> 6 b' RAFTER TIE used to secure FJ to GIRDER — RT7A-TZ H2.5AZ
<br /> J
<br /> 1-PLY HANGER 1II526-TZ,JUS28-TZ,
<br /> LUS26Z,LUS28Z,LUS210Z
<br /> JUS210-TZ
<br /> JUS26-2TZ,JUS28-2TZ, -.1.0
<br /> I L li — 2-PLY HANGER JUS210-2TZSC LUS26-2Z,LUS28-2Z,LUS210-2.Z ›,... .1.4
<br /> (1,)
<br /> LI [1] 1-PLY INVERTED FLANGE HANGER 1L26IF-TZ,JL210IF-TZ I AJC/6Z,LUC210Z C..)
<br /> ',
<br /> ,
<br /> LU MI 2-PLY INVERTED FLANGE HANGER (2)1i26IE-TZ,(2)JL210TE-TZ ILUC28-2Z,HUC,210-2Z .4.-* x.-..4 i•-
<br /> 1310:4rert '
<br /> 1 ‘... 1-PLY ADJUSTABLE SKEWED'ST HANGER ,
<br /> LSSH15-TZ LSU26Z
<br /> DCSPE#: 18-D-0189
<br /> ADJUSTABLE L-ANGLE MP5-TZ,MP7-TZ,MP9-TZ I,S50Z,LS70Z,LS9OZ Drawn By: BML
<br /> Revision History:
<br /> u ragz:c ;) ADJUSTABLE STAIR STRINGER HANGER SH TZ LSCZ - -
<br /> El FRAMING ANGLE for BLOCKING
<br /> REINFORCEMENT A3-TZ GA2 X For Construction
<br /> '''.' .;147r* c-,:'A4' e DECK TIE BACK w/ Not for Construc'on
<br /> ---,
<br /> .7 41
<br /> ..„,
<br /> 'z'kk....,44, :', ' faH3 THREADED ROD&(8)SCREWS DTB-TZ DTT22 0, •'-iorf,,,..1 \-- . , Sheet.
<br /> TENSION TIE for LEDGER REINFORCEMENT LTS19-TZ LTF19HDG N-3
<br />
|