CHAPTER 23-WOOD CHAPTER 4 -COMMERCIAL ENERGY EFFICIENCY -CONTINUED
<br /> CHAPTER 11 -ACCESSIBILITY 2304.12 PROTECTION AGAINST DECAY AND TERMITES C402.5.7 VESTIBULES
<br /> 1007.1.1 EXCEPTION 1:WHERE INTERIOR EXIT STAIRWAYS OR RAMPS ARE INTERCONNECTED BY A 1104 ACCESSIBLE ROUTE 2304.12.1.2 WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING,THAT ARE IN CONTACT WITH ALL BUILDING ENTRANCES SHALL BE PROTECTED WITH AN ENCLOSED VESTIBULE,WITH ALL DOORS
<br /> 1-HOUR FIRE-RESISTANCE-RATED CORRIDOR CONFORMING TO THE REQUIREMENTS OF 1104.4 MULTI-STORY BUILDINGS EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES FROM EXPOSED EARTH SHALL BE OPENING INTO AND OUT OF THE VESTIBULE EQUIPPED WITH SELF CLOSING DEVICES. VESTIBULES
<br /> SECTION 1020,THE REQUIRED EXIT SEPARATION SHALL BE MEASURED ALONG THE SHORTEST EXCEPTION 2:STORIES THAT DO NOT CONTAIN ACCESSIBLE ELEMENTS ARE NOT REQUIRED OF PRESERVATIVE-TREATED WOOD. SHALL BE DESIGNED SO THAT IN PASSING THROUGH THE VESTIBItLE IT IS NOT NECESSARY FOR THE
<br /> DIRECT LINE OF TRAVEL WITHIN THE CORRIDOR.
<br /> EXCEPTION 2:WHERE A BUILDING IS EQUIPPED WITH A SPRINKLER SYSTEM,WHERE TWO TO B SERVED BY AN ACESSIBLE ROUTE. INTERIOR AND EXTERIOR DOORS TO OPEN AT THE SAME TIME.
<br /> EXITS ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS,THEY SHALL BE PLACED A 2304.12.1.4 SLEEPERS AND SILLS ON A CONCRETE SLAB THAT IS IN DIRECT CONTACT WITH EARTH SHALL BE
<br /> DISTANCE APART EQUAL TO NOT LESS THAN ONE-THIRD OF THE LENGTH OF THE MAXIMUM 1106 PARKING OF PRESERVATIVE-TREATED WOOD. EXCEPTIONS:
<br /> OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED PER
<br /> 1106.2 IN GROUP R-2 OCCUPANCIES AT LEAST 2%, BUT NOT LESS THAN ONE, PARKING SPACE SHALL 1.DOORS NOT INTENDED TO BE USED AS BUILDING ENTRANCES.
<br /> EXCEPTION 1. BE ACCESSIBLE. CHAPTER 24-GLASS AND GLAZING
<br /> 1008.1 ILLUMINATION SHALL BE PROVIDED AT EVERY POINT IN THE MEANS OF EGRESS IN 2406.3 IDENTIFICATION OF SAFETY GLAZING C403 MECHANICAL SYSTEMS: .
<br /> ACCORDANCE WITH SECTION 1008.2. 1106.5 AT LEAST ONE ACCESSIBLE PARKING SPACE SHALL BE VAN-ACCESSIBLE. EACH PANE OF SAFETY GLAZING SHALL BE IDENTIFIED BY A MANUFACTURER'S DESIGNATION SEE MECHANICAL DRAWINGS FOR DESCRIPTION OF COMPLIANCE.
<br /> 2406.4 HAZARDOUS LOCATIONS REQUIRING SAFTEY GLAZING:
<br /> 1107.4 ACCESSIBLE ROUTE 2406.4.1 GLAZING IN DOORS C403.2.4.11 GROUP R-2 SLEEPING UNITS:THE PRIMARY SPACE CONDITIONING SYSTEM WITHIN EACH SLEEPING
<br /> 1008.2.1 THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS THAN 1 FOOTCANDLE AT UNIT SHALL BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR THE
<br /> THE WALKING SURFACE. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDING ENTRANCES WITH 2406.4.2 GLAZING WITHIN 24 INCHES OF EITHER VERTICAL EDGE OF DOOR,WHERE THE BOTTOM EDGE IS REGULATION OF SPACE TEMPERATURE.THE THERMOSTAT SHALL ALLOW FOR,AT A MINIMUM,A 5-2
<br /> THE PRIMARY ENTRANCE OF EACH ACCESSIBLE UNIT,TYPE A UNIT AND TYPE B UNIT WITHIN LESS THAN60 INCHES ABOVE THE FLOOR PROGRAMMABLE SCHEDULE(WEEKDAYS/WEEKENDS)AND BE CAPABLE OR PROVIDING AT LEAST
<br /> 1008.3.1 IN THE EVENT OF A POWER SUPPLY FAILURE,AN EMERGENCY ELECTRICAL SYSTEM SHALL THE BUILDING AND WITH THOSE EXTERIOR AND INTERIOR SPACES THAT SERVE THE UNITS. 2406.3 GLAZING IN WINDOWS, IF: TWO PROGRAMMABLE SETBACK PERIODS PER DAY.
<br /> AUTOMATICALLY ILLUMINATE CORRIDORS AND EXIST STAIRWAYS. 1.THE PANE OF GLAZING>9 SF SEE MECHANICAL DRAWINGS FOR DESCRIPTION OF COMPLIANCE.
<br /> 1107.6.2.2.1 TYPE A UNITS 2.THE BOTTOM OF THE GLAZING IS<18 INCHES ABOVE THE FLOOR
<br /> 1009 ACCESSIBLE MEANS OF EGRESS IN GROUP R-2 OCCUPANCIES CONTAINING MORE THAN 20 DWELLING UNITS,AT LEAST 2 3.THE TOP OF THE GLAZING IS>36 INCHES ABOVE THE FLOOR C403.2.6 VENTILATION:VENTILATION, EITHER NATURAL OR MECHANICAL,SHALL BE PROVIDED IN
<br /> 1009.2 CONTINUITY AND COMPONENTS. EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE PERCENT BUT NOT LESS THAN ONE UNIT SHALL BE A TYPE A UNIT, DISBURSED AMONG THE 4.A WALKING SURFACE IS WITHIN 36 INCHES OF THE PANE OF GLAZING ACCORDANCE WITH CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE.WHERE MECHANICAL -
<br /> CONTINUOUS TO A PUBLIC WAY AND SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING CLASSES OF UNITS. 2406.4.5 GLAZING ADJACENT TO TUBS AND SHOWERS<60 INCHES ABOVE THE FLOOR VENTILATION IS PROVIDED,THE SYSTEM SHALL PROVIDE THE CAPABILITY TO REDUCE THE OUTDOOR
<br /> COMPONENTS: 2406.4.6 GLAZING ADJACENT TO STAIRWAYS<60 INCHES ABOVE THE PLANE OF THE STAIRS OR LANDING AIR SUPPLY TO THE MINIMUM REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE.
<br /> INTERIOR EXIT STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1023. NUMBER OF UNITS TYPE A UNITS REQUIRED(5 PERCENT) TYPE A UNITS PROVIDED 2406.4.7 GLAZING ADJACENT TO THE BOTTOM STAIRWAY LANDING <60 INCHES ABOVE THE LANDING
<br /> 65 4 TYPE A 6 MECHANICAL VENTILATION IS PROVIDED
<br /> CHAPTER 25-GYPSUM SEE MECHANICAL DRAWINGS M1.1-M1.4
<br /> 1009.2.1 ELEVATORS REQUIRED. COMMUNICATION UNITS PROVIDED(2 PERCENT)=2 REQUIRED,2 PROVIDED NOT APPLICABLE
<br /> IN BUILDINGS WHERE A REQUIRED ACCESSIBLE FLOOR IS FOUR OR MORE STORIES ABOVE A C404 SERVICE WATER-HEATING�MANDATORYI:
<br /> LEVEL OF EXIT DISCHARGE, NOT LESS THAN ONE REQUIRED ACCESSIBLE MEANS OF EGRESS SEE PLUMBING DRAWINGS FOR DESCRIPTION OF COMPLIANCE W►TH ALL APPLICABLE SECTlON
<br /> 1107.6.2.2.2 TYPE B UNITS CHAPTER 26-PLASTIC
<br /> SHALL BE AN ELEVATOR COMPLYING WITH SECTION 1009.4. IN GROUP R-2 OCCUPANCIES CONTAINING MORE THAN 4 DWELLING UNITS, EVERY UNIT SHALL BE A NOT APPLICABLE C404 SERVICE WATER HEATING SYSTEMS REQUIREMENTS.
<br /> EXCEPTIONS:
<br /> 1. IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM TYPE B UNIT.
<br /> INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2,THE ELEVATOR SHALL NOT CHAPTER 27-ELECTRICAL C405 ELECTRICAL POWER AND LIGHTING SYSTEMS:
<br /> BE REQUIRED ON FLOORS PROVIDED WITH A HORIZONTAL EXIT AND LOCATED AT OR ABOVE CHAPTER 12-INTERIOR ENVIRONMENT SEE ELECTRICAL DRAWINGS SEE ELECTRICAL DRAWINGS FOR DESCR/PTION OF COMPL►ANCE W1TH ALL APPLICABLE SECTION
<br /> 1203.1 VENTILATION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS REQUIREMENTS.
<br /> THE LEVELS OF EXIT DISCHARGE. BUILDING SHALL BE PROVIDED WITH NATURAL VENTILATION IN ACCORDANCE WITH SECTION 1203.4 CHAPTER 28-MECHANICAL SYSTEMS
<br /> 1009.4 ELEVATORS OR MECHANICAL VENTILATION IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE. SEE MECHANICAL DRAWWGS C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
<br /> EXCEPTION 2:AREAS OF REFUGE ARE NOT REQUIRED IN BUILDINGS EQUIPPED WITH AN BUILDINGS SHALL COMPLY WITH TWO
<br /> 1203.5.1 NATURAL VENTILATION CHAPTER 29-PLUMBING SYSTEMS
<br /> AUTOMAT�C SPRINKLER SYSTEM. PER ESDS BUILDING SHALL COMPLY WITH ONE ADDITIONAL '
<br /> 1010.1.1 SIZE OF DOORS GROUP R OCCUPANCIES SHALL COMPLY WITH THE INTERNATIONAL MECHANICAL CODE. TABLE TOTAL OPTIONS REQUIRED-3
<br /> MEANS OF EGRESS DOORS SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 32 INCHES 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
<br /> 1204.1 TEMPERATURE CONTROL OCCUPANCY WATER CLOSETS LAVATORIES 1.ON SITE SUPPLY OF RENEWABLE ENERGY IN ACCORDANCE WITH SECTION C406.5
<br /> INTERIOR SPACES SHALL BE PROVIDED WITH SPACE HEATING CAPABLE OF MAINTAINING AN B 1 PER 25 FOR THE 1 PER 40 FOR THE
<br /> 1010.1.6 LANDINGS AT DOORS 2. PROVISIONS OF A DEDICATED OUTDOOR AIR SYSTEM FOR CERTAIN HVAC EQUIPMENT IN
<br /> LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, INDOOR TEMPERATURE OF NOT LESS THAN 68°F FIRST 50 AND 1 PER 50 FIRST 80 AND 1 PER 80
<br /> FOR THE REMAINDER FOR THE REMAINDER ACCORDANCE WITH SECTION C406.6
<br /> WHICHEVER IS GREATER.DOORS IN THE FULLY OPEN POSITION SHALL NOT REDUCE A 3.HIGH EFFICIENCY SERVICE WATER HEATING IN ACCORDANCE WITH SECTION C406.7
<br /> REQUIRED DIMENSION BY MORE THAN 7 INCHES.WHEN DOORS OPEN OVER LANDINGS, 1205.1 LIGHTING EXCEEDING 50 EXCEEDING 80
<br /> DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING LENGTH TO LESS THAN ONE-HALF EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SNALI.BE PROVIDED WITH NATURAL LIGHT OR
<br /> ARTIFICIAL LIGHT. R-2 ONE PER DWELLING UNIT ONE PER DWELLING UNIT C408 SYSTEM COMMISSIONING:
<br /> ITS REQUIRED WIDTH. LANDINGS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF SEE MECHANICAL DRAWINGS FOR DESCRIPTION OF COMPLIANCE W►TH AL!APPLICABLE
<br /> TRAVEL OF NOT LESS THAN 44 INCHES. 1205.2 NATURAL LIGHT 2902.2 WHERE PLUMBWG FIXTURES ARE REQUIRED,SEPARATE FACILITIES SHALL BE PROVIDED FOR SECTiON C408 SYSTEMS COMMISSIONING REQUIREMENTS. �
<br /> ii `
<br /> THE MINIMUM NET GLAZED AREA SHALL BE NOT�ESS THAN 8 PERCENT OF THE FLOOR AREA OF EACH SEX. �
<br /> 1011.2 STAIRWAY WIDTH AND CAPACITY C409 ENERGY METERING AND ENERGY CONSUMPTION MANAGEMENT
<br /> EXCEPTION 1.STAIRWAYS SERVING AN OCCUPANT LOAD OF LESS THAN 50 SHALL HAVE A THE ROOM BEING SERVED . }
<br /> WIDTH OF NOT LESS THAN 36 INCHES. CHAPTER 30-ELEVATORS AND CONVEYING SYSTEMS BELOW 50,000 S.F. THRESHOLD. P,I�V I r O n I�P I�l�I �
<br /> 1205.3 ARTIFICIAL LIGHT �0���
<br /> 1013.1 EXIT SIGNS ARTIFICIAL LIGHT SHALL BE PROVIDED THAT PROVIDES AN AVERAGE ILLUMINATION OF 10 3002.4 WHERE ELEVATORS ARE PROVIDED IN BUILDINGS FOUR OR MORE STORIES ABOVE GRADE,THE FROM TABLE C402.1.3
<br /> EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY FOOTCANDLES ELEVATOR CAR SHALL ACCOMMODATE AN AMBULANCE STRETCHER. Community Design Center
<br /> VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL.THE PATH OF EGRESS TRAVEL TO EXITS 3005.2 ELEVATOR MACHINE ROOMS SHALL BE VENTILATED OR AIR-CONDITIONED TO PREVENT BUILDING ELEMENT REQUIRED VALUE ACTUAL VALUE
<br /> AND WITHIN EXITS SHALL BE MARKED BY READILY VISIBLE EXIT SIGNS TO CLEARLY INDICATE 1207 SOUND TRANSMISSION OVERHEATING.
<br /> THE DIRECTION OF EGRESS TRAVEL 1207.2 AIR-BORNE SOUND EXCEPTION: IN BUILDING FOUR STORIES OR LESS,NATURAL OR MECHANICAL VENTILATION MAY BE 402 15th Avenue East
<br /> EXTERIOR WALLS R-21 INT R-29 INT
<br /> TABLE ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS SHALL USED IN LIEU OF AN INDEPENDENT SYSTEM. Seattle,Washington 98112
<br /> HAVE AN STC RATING NOT LESS THAN 50. 3016.4 REQUIREMENTS TO ACCOMMODATE PEOP�E WITH DISABILITIES ATTIC AND OTHER ROOFS R-49 R-60 206.329.8300
<br /> 1017.2 EXIT ACCESS TRAVEL DISTANCE DWELLING UNIT ENTRANCE DOORS FROM INTERIOR CORRIDORS SHALLBE TIGHT-FITTING TO THE ALL NEW ELEVATORS SHALL COMPLY WITH CHAPTER 11 206.329.5494 fax
<br /> (WITH SPRINKLER SYSTEM)
<br /> OCCUPANCY FRAME AND SILL. ROOF JOISTS AND SINGLE RAFTER R-49 -
<br /> CHAPTER 31 -SPECIAL CONSTRUCTION SLAB ON GRADE R-10 FOR 24" R-10 CONTINUOUS
<br /> B 300 FEET 1207.3 STRUCTURE-BORNE SOUND NOT APPLICABLE JOIST FRAMING R-30 c.i. R-32.5
<br /> R-2 250 FEET FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR BETWEEN DWELLING UNITS AND
<br /> S-2 400 FEET OTHER SPACES SHALL HAVE AN IIC RATING OF NOT LESS THAN 50 CHAPTER 32-ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY OPAQUE DOORS 0.37 0.37
<br /> 1020.1 CORRIDORS
<br /> CONSTRUCTION.CORRIDORS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH NOT APPLICABLE verett
<br /> TABLE 1020.1.THE CORRIDOR WALLS REQUIRED TO BE FIRE-RESISTANCE RATED SHALL 1208.1 MINIMUM ROOM WIDTHS GLAZING U-VALUES U-VALUES
<br /> COMPLY WITH SECTION 708 FOR FIRE PARTITIONS. HABITABLE SPACES OTHER THAN A KITCHEN,SHALL BE NOT LESS THAN 7 FEET IN ANY PLAN CHAPTER 33-SAFEGUARDS DURING CONSTRUCTION NONMETAL FRAMING 0.30 0.17 Safe Streets
<br /> EXCEPTION 4.A FIRE-RESISTANCE RATING IS NOT REQUIRED FOR CORRIDORS IN AN DIMENSION NOT APPLICABLE
<br /> OCCUPANCY IN GROUP B THAT IS A SPACE REQUIRING ONLY A SINGLE MEANS OF EGRESS STOREFRONT 0.60 0.60 S U ppO�IVe
<br /> COMPLYING WITH SECTION 1006.2. 1208.2 MINIMUM CEILING HEIGHTS HOUSIng
<br /> EXCEPTION 7.THE OCCUPANT LOAD OF GROUP B CONFERENCE ROOMS,LUNCH ROOMS OCCUPIABLE SPACES,HABITABLE SPACES AND CORRIDORS SHALL HAVE A CEILING HEIGHT OF NOT CHAPTER 4 -COMMERCIAL ENERGY EFFICIENCY SHGC ORIENTATION SHGC
<br /> WITHOUT GREASE-PRODUCING COOKING AND OTHER ASSEMBLY ROOMS WITH AN OCCUPANT LESS THAN 7 FEET 6 INCHES.
<br /> LOAD OF LESS THAN 50 IN EACH ROOM NEED NOT BE CONSIDERED WHEN DETERMINING BATHROOMS,TOILET ROOMS, KITCHENS,STORAGE ROOMS AND LAUNDRY ROOMS SHALL HAVE A C401.2 COMMERCIAL BUILD►NGS SHALL COMPLY WITH ONE OF THE FOLLOWING: 0.3 @ FIBERGLASS 6200 12th Dr. SE
<br /> WHETHER CORRIDOR CONSTRUCTION IS REQUIRED CEILING HEIGHT OF NOT LESS THAN 7 FEET. 1.THE REQUIREMENTS OF SECTIONS C402,C403,C404,C405,C408,C409 AND C410 WINDOWS/DOORS(NON-METAL) 0.53 @ N, .40 @ SEW .24 @ VINYL � Everett, WA 98203 ,
<br /> TABLE 1208.3 ROOM AREA C402.1 GENERAL STOREFRONT 0.53 @ N, .40 @ SEW 0.53 @ N, .40 @ SEW
<br /> 1020.1 CORRIDOR FIRE-RESISTANCE RATING EVERY DWELLING UNIT SHALL NAVE AT LEAST ONE ROOM THAT SHALL HAVE NOT LESS THAN 120 SEE PERSCRIPTIVE PERFORMANCE SPREADSHEET BELOW 5807
<br /> OCCUPANCY OCCUPANT LOAD SERVED REQUIRED RATiNG SQUARE FEET OF NET FLOOR AREA 1. THE OPAQUE PORTION OF THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH THE Rt�1ST�RED
<br /> BY CORRIDOR (SPRINKLERED BUILDING) � •
<br /> SPECIFIC INSULATION REQUIREMENTS OF SECTION 402.2 AND THE THERMAL REQUIREMENTS OF R����3����T
<br /> B GREATER THAN 30 0 1210 TOILET AND BATHROOM REQUIREMENTS EITHER THE R-VALUE BASED METHOD OF SECTION C402.1.3,THE U-,C-AND F-FACTOR BASED /, J.
<br /> METHOD OF SECTION C402.1.4 OR THE COMPONENT PERFORMANCE ALTERNATNE OF SECTION G�
<br /> R-2 GREATER THAN 10 0.5 1210.2.1 TOILET,BATHING,AND SHOWER ROOM FLOOR FINISHES HALL HAVE A SMOOTH, HARD, VVILLi��t�9�. Slt�GE
<br /> C402.1.5.
<br /> S GREATER THAN 30 � NON-ABSORBENT SURFACE 2. FENESTRATION IN THE BUILDING ENVELOPE ASSEMBLIES SHALL COMPLY WITH SECTION C402.4 �TATE Ot V��r�St�l'VGTON �
<br /> � 1020.2 CORRIDOR WIDTH 3. AIR LEAKAGE OF BUILDING ENVELOPE ASSEMBLIES SHALL COMPLY WITH SECTION C402.5 �`�`�'
<br /> MINIMUM WIDTH-44"EXCEPT TABLE 1020.2 ALLOWS WIDTH-36"WHEN OCCUPANT LOAD<50 1210.2.2 WALLS WITHIN 2 FEET OF SERVICE SINKS,URINALS,AND WATER CLOSETS SHALL HAVE A SMOOTH,
<br /> HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF 4 FEET ABOVE THE FLOOR.
<br /> 1020.4 DEAD ENDS C402.1.3 INSULATION COMPONENT R-VALUE METHOD
<br /> WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED,THE EXIT ACCESS CHAPTER 13-ENERGY EFFICIENCY BUILDING THERMAL ENVELOPE OPAUE ASSEMBLIES SHALL MEET THE REQUIREMENTS OF SECTION
<br /> SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 REFERENCE THE INTERNATIONAL ENERGY CONSERVATION CODE. C402.2 BASED ON THE CLIMATE ZONE SPECIFIED IN CHAPTER 3. FOR OPAGUE PORTIONS OF THE
<br /> BUILDING THERMAL ENVELOPE INTENDED TO COMPLY ON AN INSULATION COMPONENT R-VALUE Buildin Code Notes
<br /> FEET IN LENGTH. CHAPTER 14-EXTERIOR WALLS BASIS,THE R-VALUES FOR INSULATION IN FRAMING AREAS,WHERE REQUIRED,AND FOR g
<br /> EXCEPTIONS: 1403.2 WEATHER PROTECTION CONTINUOUS INSULATION,WHERE REQUIRED SHALL NOT BE LESS THAN THAT SPECIFIED IN TABEL
<br /> 2. IN OCCUPANCIES IN GROUPS B, R-2,AND S,WHERE THE BUILDING IS EQUIPPED Energy Code Notes
<br /> THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM THE LENGTH OF THE DEAD-END EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL C402.1.3. COMMERCIAL BUILDWGS OR PORTIONS OF COMMERCIAL BUILDWGS ENCLOSING GROUP R -
<br /> CORRIDORS SHALL NOT EXCEED 50 FEET ENVELOPE.THE EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING,AS DESCRIBED IN SECTION OCCUPANCIES SHALL USE THE R-VALUES FROM THE GROUP R COLUMN OF TABLE C402.1.3.
<br /> 1405.4.THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN SUCH A
<br /> 1023.2 INTERIOR EXIT STAIRWAYS MANNER AS TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY
<br /> INTERIOR EXIT STAIRWAY AND RAMP ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING PROVIDING A WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER,AS DESCRIBED IN C402.5 AIR LEAKAGE
<br /> OF NOT LESS THAN 2 HOURS WHERE CONNECTING MORE THAN FOUR STORIES. SECTION 1404.2,AND A MEANS FOR DRAINING WATER THAT ENTERS THE ASSEMBLY TO THE THE THERMAL ENVELOPE OF BUILDWGS SHALL COMPLY WITH SECTION C402.5.1 THROUGH C402.5.8
<br /> EXTERIOR
<br /> 1023.7 WTERIOR EXIT STAIRWAY EXTERIOR WALLS C402.5.1 AIR BARRIER-A CONTINUOUS AIR BARRIER SHALL BE PROVIDED THOUGHOUT THE BUILDING
<br /> EXTERIOR WALLS OF THE INTERIOR EXIST STAIRWAY SHALL COMPLY WITH THE 1405.3.1 CLASS I AND II VAPOR RETARDERS THERMAL ENVELOPE(SEE AIR BARRIER DIAGRAM ON T1.4)
<br /> REQUIREMENTS OF SECTION 705 FOR EXTERIOR WALLS(1-HOUR RATED). CLASS I OR II VAPOR RETARDERS SHALL BE PROVIDED ON THE INTERIOR SIDE OF FRAME WALLS IN 1. THE AIR BARRIER SHALL BE CONTINUOUS FOR ALL ASSEMBLIES THAT ARE THE THERMAL Date
<br /> ZONE MARINE 4. ENVELOPE OF THE BUILDING AND ACROSS THE JOINTS AND ASSEMBLIES. ZG .�a11Ua1"'�/ ZO�S
<br /> 1023.9 STAIRWAY IDENTIFICATION SIGNS TABLE 2. AIR BARRIERS JOINTS AND SEAMS SHALL BE SEALED, INCLUDING SEALING TRANSITIONS IN
<br /> A SIGN SHALL BE PROVIDED AT EACH FLOOR LANDING IN AN INTERIOR EXIT STAIRWAY 1405.3.2 A CLASS III VAPOR RETARDER WITH A PERM RATING> 1.0 AND<_10.0(E.G. PAINT)IS PERMITTED PLACES AND CHANGES IN MATERIALS. AIR BARRIER PENETRATIONS SHALL BE SEALED IN Permit & Construction Set .
<br /> CONNECTING MORE THAN THREE STORIES DESIGNATING THE FLOOR LEVEL,THE TERMINUS FOR VENTED CLADDING OVER GYPSUM. ACCORDANCE WITH SECTION C402.4.2.THE JOINTS AND SEALS SHALL BE SECURELY INSTALLED Revisions
<br /> OF THE TOP AND BOTTOM OF THE INTERIOR EXIT STAIRWAY AND THE IDENTIFICATION OF THE IN ORON THE JOINT FOR ITS ENTIRE LENGHT SOAS NOT TO DISLODGE,LOOSEN OR OTHERWISE
<br /> STAIRWAY.THE SIGNAGE SHALL ALSO STATE THE STORY OF,AND THE DIRECTION T0,THE CHAPTER 15-ROOF ASSEMBLIES AND ROOFTOP STRUCTURES IMPAIR ITS ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FORM WIND,STACK EFFEC 28 July 2017 Bldg. Permit Submittal
<br /> EXIT DISCHARGE AND TABLE AND MECHANICAL VENITLATION.
<br /> WHETHER THERE IS ROOF ACCESS FROM THE INTERIOR EXIT STAIRWAY FOR THE FIRE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
<br /> DEPARTMENT. CONSTRUCTION TYPE REQUIRED ROOF ASSEMBLY C402.5.1.2 BUILDING TEST 1 28 Sept.2017 Addendum#1
<br /> V-A B THE COMPLETE BUILDING SHALL BE TESTED AND THE AIR LEAKAGE RATE OF THE BUILDING
<br /> 2 06 Oct.2017 Addendum#2
<br /> ENVELOPE SHALL NOT EXCEED 0.40 CFM/SQ.FT.AT A PRESSURE DEFFERENTIAL OF 0.3 INCHES - - ---
<br /> 1030.1 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE PROVIDED IN R-2 OCCUPANCIES. CHAPTER 16-STRUCTURAL DESIGN WATER GAUGE(2.0 L/s M-SQUATED AT 75 Pa) IN ACCORDANCE WITH ASTM E779 OR AN EQUIVALENT 3 16 Oct.2017 Permit Corrections
<br /> SLEEPING ROOMS BELOW THE FOURTH STORY ABOVE GRADE PLANE SHALL HAVE AT LEAST SEE STRUCTURAL DRAWINGS METHOD APPROVED BY THE CODE OFFICIAL A REPORT THAT INCLUDES THE TESTED SURFACE AREA,
<br /> ONE EMERGENCY ESCAPE AND RESCUE OPENING. 4 26 Jan.2018 Permit Corrections
<br /> FLOOR AREA,AIR BY VOLUM,STORIES ABOVE GRADE,AND LEAKAGE RATES SHALL BE SUBMITTED TO - --- - - ---- --
<br /> 1030.2 MINIMUM SIZE CHAPTER 17 -SPECIAL INSPECTIONS AND TESTS THE BUILDING OWNER AND THE CODE OFFICIAL. IF THE TESTED RATE EXCEEDS THAT DEFINED
<br /> EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVEA MINIMUM NET CLEAR OPENING
<br /> SEE STRUCTURAL DRAWINGS HERE,A VISUAL WSPECTION OF THE AIR BARRIER SHALLBE CONDUCTED AND ANY LEAKS NOTED
<br /> SHALL BE SEALED TO THE EXTENT PRACITCABLE. AN ADDITIONAL REPORT IDENTIFYING THE Drawn by:
<br /> - __-----
<br /> OF 5.7 SF CHAPTER 18-SOILS AND FOUNDATIONS CORRECTIVE ACTIONS TAKEN TO SEAL AIR LEAKS SHALL BE SUBMITTED TO THE BOULDING OWNER CC/SC/MM
<br /> 1030.2.1 MINIMUM DIMENSIONS SEE STRUCTURAL DRAWINGS AND THE CODE OFFICIAL AND ANY FURTHER REQUIREMENT TO MEET THE LEAKAGE RATE WILL BE
<br /> _ _----_ _ _ . _ __
<br /> THE MINIMUM NET CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES.THE MtNIMUM WAIVED. Checked by_(P.M.):
<br /> --
<br /> NET CLEAR OPENING WIDTH SHALL BE 20 INCHES. CHAPTER 19-CONCRETE CC
<br /> SEE STRUCTURAL DRAWINGS C402.5.4 DOORS AND ACCESS OPENINGS TO SHAFTS
<br /> 1030.3 MAXIMUM HEIGHT FROM FLOOR DOORS AND ACCESS OPENINGS FROM CONDITIONED SPACE TO SHAFTS,CHUTES,STAIRWAYS AND _ Checked by(Q.C.):
<br /> THE BOTTOM OF THE CLEAR OPENING SHALL BE NOT GREATER THAN 44 INCHES MEASURED CHAPTER 20-ALUMINUM ELEVATOR LOBBIES SHALL BE GASKETED WEATHERSTRIPPED OR SEALED. BS/MM
<br /> NOT APPLICABLE
<br /> FROM THE FLOOR. Pro ect No.
<br /> C402.5.5 AIR INTAKES.EXHAUST OPENINGS.STAIRWAYS AND SHAFTS - - ------ �-
<br /> CHAPTER 21 -MASONRY STAIRWAY ENCLOSURES, ELEVATORS SHAFTS VENTS AND OTHER OUTDOOR AIR INTAKES AND 'I G-O29A
<br /> NOT APPLICABLE EXHAUST OPENINGS INTEGRAL TO THE BUILDING ENVELOPE SHALL BE PROVIDED WITH DAMPERS W ---
<br /> ACCORDANCE WITH SECTION C403.2.4.3
<br /> CHAPTER 22-STEEL
<br /> SEE STRUCTURAL DRAWINGS �
<br /> T1 . 3 ��
<br /> ..
<br />
|