Laserfiche WebLink
ti. <br /> WATER CLOSET NOTES� <br /> 1. GRAB BARS MUST WITHSTAND 250L6 LOAD <br /> ------MIRROR <br /> . / <br /> � -SOAP DISP. 3 39"-4T' <br /> FLUSH CONTROLS � 18 54 MW� <br /> , PAPER TOWEL DISP. � 1 11..W. 12 MAX. 42"MIN. i � � ` <br /> LOCATED ON THE <br /> �--36 SINK � ,��� OPEN SIDE OF '� � �` � � �i <br /> -- , iv�i �. ,� . <br /> � __. �. � <br /> \ _ <br /> EXPOSED PIPES AND SURFACES - WALL HUNG SWK,TYP. WATER CLOSET-- \ I I i , I <br /> Y � _ ; � ; SHALL BE INSULATED, NO SHARP � � _�`� ---INSULATION ON ALL EXPOSED � <br /> � � � � <br /> � c� � ; z , �'� �,� �� OR ABRASIVE SURFACES UNDER � o I _ � <br /> _ � � <br /> . � M o ; _ PLUMBWG SUPPLYAND WASTE - ^ r- _ _ ��--'� <br /> M <br /> o - ' i <br /> � __.��'���� � �� � W KS � _ � '� `h �I <br /> � �.,� ��� LINES(TYP.@ TYPE'A'UNITS} <br /> � � ,, �.�OPEN � II FINISN I �,� <br /> 2'-6"CLR. FLOOR � _____,_ _ _ � �,�, I � , N M �;j <br /> � - <br /> f MIN. � ' : <br /> � <br /> , 3, 3„ , <br /> ,��-3 i ,�_ __ f , . <br /> FRONT VIEW MIN. <br /> KITCHEN SINK <br /> ACCESSIBLE WATER CLOSET ACCESSIBLE WATER CLOSET <br /> �� Typical Kitchen Sink at Common Areas 7 T ical Sink at Common Ar � <br /> Scale: 1/4° _ ��-o° Yp ea Restroom 3 Typical Water Closet Elevations at Common Areas <br /> A6.1 A6.1 Scale: 1i4" = 1'-0" Scale: 1/4" = 1'-0" <br /> A6.1 <br /> WATER CLOSET NOTES� <br /> 1. GRAB BARS MUST WITHSTAND 250LB LOAD <br /> 2. AT TYPE'A'UN�TS PROVIDE BLOCKING AND AND - <br /> GRAB BARS AS REQ'D <br /> 3. AT TYPE'B'UNITS PROVIDE BLOCKING AS REQ'D <br /> FOR FUTURE INSTALLATION OF GRAB BARS. <br /> � _ �,�------LIGHT BLOCKING FOR VERTICAL GRAB BAR NOT <br /> - � - REQ'D. <br /> --FIRE EXTINQUISHER CABINET j� MIRROR <br /> � �� <br /> � � - <br /> li <br /> � 39" 41 <br /> -FIRE EXTINQUISHER '� I � 36"MIN. � <br /> 54' MIN � <br /> - _ __-,✓ <br /> ;i -FIRE EXTINQUISHER � BLOCKING AS REQ'D--� ' _ __ 18" 12 MAX. 42"MIN. ' � BLOCKING <br /> __ -- <br /> � ��'_ <br /> � .� � �`�AS REQ'D <br /> �C/ CABINET DOOR HANDLE --- INSULATION ON ALL EXPOSED � MIN. ;�, r � <br /> ��'/ ��� --- FLUSH CONTROLS LOCATED ON V /-f_ - , �� .P .-� <br /> --I- �-- - ____ ! ` � PLUMBING SUPPLY AND WASTE ' <br /> OPEN SIDE OF WATER CLOSET-� � � ; � / �'z � <br /> � ' <br /> �_.__iI,,I` i � ; LINES(TYP. @ TYPE'A'UNITS) \I � I � i �� �� .' <br /> i L_J_ _. . _O �I � _ � � I \.__. �'-�, i . , �_ ��.. - ..' <br /> _ -_- --_- co ��� �� i <br /> c� � � _ ° <br /> ' o �'z h- � � � <br /> _ � _ . . M I �. . : �i'�,. _ ,.� • � . <br /> �'.� ��, �� � � ��...Y .. ,��_�n . M N - <br /> N <br /> � <br /> _-.. .___. . _. �. <br /> __ ___ __ m � w o � o'Z �MIN� <br /> - nvironmen a <br /> N� C'7, ��'�.. <br /> _-._.. .._.. _-. _ _ . ' <br /> z w - � ___ _�, � Q N o � WORKS <br /> a,� � � ~ z �� 3�_3�� . <br /> zQ m � g � / Community Design Center <br /> o = � � <br /> �,� � <br /> o'Q FRONT VIEW Seatt�e, Wash nVton 98112 <br /> `�'� ACCESSIBLE WATER CLOSET 9 <br /> M o BATHROOM SINK ACCESSIBLE WATER CLOSET 206.329.8300 <br /> 206.329.5494 fax <br /> �o Fire Extinquisher Mounting Hei hts 6 T ical Bathroom Sink at T ' ' � � <br /> Scale: 1/4�� _ ��-o�� Yp ype A & Type B Units 2 Typical Water Closet at Type 'A' & T e 'B' Units <br /> A6.1 Scale: 1/4" = 1'-0" p <br /> SHOWER NOTES: <br /> A6.1 A6.1 Scale: 1/4" = 1'-0" <br /> 1. GRAB BARS MUST WITHSTAND 250LB LOAD WATER CLOSET NOTES� EVerett <br /> 2. AT TYPE'B'UNITS PROVIDE BLOCKING AS REQ'D <br /> FOR FUTURE INSTALLATION OF GRAB BARS. 1. GRAB BARS MUST WITHSTAND 250LB LOAD Safe Streets <br /> BLOCKING FOR VERTICAL GRAB BAR NOT 2. AT TYPE'A'UNITS PROVIDE BLOCKING AND AND <br /> REQ'D. GRAB BARS AS REQ'D Supportive <br /> 3. AT TYPE'B'UNITS PROVIDE BLOCKING AS REQ'D <br /> FOR FUTURE INSTALLATION OF GRAB BARS. HOUSII�g <br /> ,-- -CONTROL END <br /> 6200 12th Dr. SE <br /> � z �4"MIN/ 12 MAX. �24"MIN/ 24"MAX. � /12 MIN. Everett, WA 98203 . <br /> _- --._ _ o � <br /> Y � � <br /> ' o,o /,;-----SINK __---COUNTERTOP <br /> � � 1-6 � �, �-: � �-----COUNTERTOP � ' 4" �,, . ; ��� �, 5807 � ' <br /> � �� _ r , <br /> .r - \__ _ _ __ <br /> WORK SURFACE,30"MIN. � ��, �Et�iST�REf� <br /> Q I -INSULATION ON ALL EXPOSED � WIDTH KNEE SPACE �'z �I i <br /> � ' AP�t'lT�� <br /> � ��� , � � I � , , 7' <br /> � ,� .,' - ' `� _ -_- I <br /> M � ��.!� PLUMBING SUPPLY AND WASTE � � _ � ) ' ' <br /> ��-- - - � �\ �� � �� z� i� �� ---REMOVABLE BASE CABINET "� � , ������ � �� L!�� <br /> - ��� LINES(TYP.@ TYPE'A'UNITS) N, - _ � � � '„ <br /> � - <br /> , ' ' � � ��. <br /> � _ , ��� � � M � ��, �� � � �'� � ���' VYlLf.il��!�. SJ€vGE <br /> �, � ' FIN. FLR. , � � <br /> M M �- FIN. FLR. - � - STATE pr 1�J�1S�i1iVGTON <br /> , <br /> _ . M'. � ,.. �,. � <br /> � . . ,... , �. <br /> _.._.� ' I , . M� � ., M I .\ M� � <br /> ' c ."`� <br /> , _�'/__. .__.. ._7� M .., M I � M� <br /> 2'-6"MIN. ' <br /> MIN.30"CLEAR � �-----� <br /> 3 _ _ � <br /> WALL FACING CONTROL END WALL FACING BACK WALL SEAT WALL � CLR. 'K AFTER REMOVAL ' '� <br /> 12 ' <br /> ypical Shower at Type �B� Un�ts CONTROLS SHALL BE LOCATED %' <br /> r' <br /> BETWEEN THE OPEN SIDE OF � ACC@SSIIJIII�)/ D@t81IS <br /> A6,1 Scale: 1/4" = 1'-0" ; � <br /> THE BATHTUB&THE MIDPOINT ! � � <br /> FRONT VIEW OF THE WIDTH OF THE BATHTUB- --'' <br /> FRONT VIEW KITCHEN WORK SURFACE and Notes <br /> SHOWER NOTES: KITCHEN SINK <br /> . <br /> WALL FACING CONTROL END WALL FACING BACK WALL WALL FACING HEAD END <br /> . A B B A R S M U S T W I T H S T A N D 2 5 0 L B LOAD 9 T pical Kitchen Sink at Type �A� Un�ts 5 ' � � � <br /> 2. GRAB BARS ARE AS PROVIDED BY UNIT Typical Work Surface Elevation at Type A Kitchens � � � � <br /> SHOWER MFR WI INTEGRATE Scale: 1/4�� _ ��-�" <br /> A6.1 Typical Tub/Shower at Type A Units & Type 'B' Units <br /> BLOCKING/BACKING AS REQ'D FOR ANCHORAGE A6 � Scale: 1/4�� _ ��-��� SCa�e: ��4 - � -� <br /> &SUPPORT A6.� _ <br /> 3. HAND SHOWER TO BE ON 24"SLIDE BAR W/60" <br /> (MIN.)LONG HOSE-HOSE LENGTH TO General Accessibilitv Notes <br /> ACCOMMODATE USE ON HOOK PROVIDED @ _ <br /> END WALL <br /> 1. ALL FIXTURES,DIMENSIONS,AND CLEARANCES IN TYPE A UNITS SHALL COMPLY WITH ANSI 117.1-2009. Date � <br /> �5'-0"(CLR INTERIOR)� - <br /> _ _26 January 2018 <br /> � 2�_3�� � , 2. ALL OPERABLE PARTS IN TYPE A UNITS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT ° <br /> GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVIATE SHALL BE 5.0 POUNDS MAX.ALL Permit & Construction Set <br /> OPERABLE PARTS SHALL BE PLACED BETWEEN 15"AND 48" HEIGHT AFF,WHERE UNOBSTRUCTED,AND BETWEEN 34"AND <br /> / 1'-8' / /6' MAX 2'-10"(CLR INTERIOR) 42"AFF WNERE OBSTRUCTED. Revisions <br /> - . <br /> ' 28 July 2017 Bldg. Permit Submittal <br /> 2'-10"(CLR INTERIOR) 2. PROVIDE REINFORCED BLOCKING AND GRAB BARS tN ALL TYPE'A' UNITS IN COMPLIANCE WITH ANSI 117.01 (2009). <br /> --HAND SHOWER - __ --SHELF PROVIDE REINFORCED BLOCKING IN ALL TYPE'B'UNITS. GRAB BARS MUST WITHSTA <br /> r , ' j SHELF _ <br /> --HAND SHOWER � � ____� � \ � � ����-ROD � ND 250LB LOAD <br /> �---- -- -C --r'-- / <br /> - � - � - -- <br /> � 1 r � _ � �� ������� � �� � __ � � ���� �-� ROD __ <br /> � 28 Sept.2017 Addendum#1 <br /> I \ -- <br /> % /" 3. PER ANSI 607.5,COMBINED BATH AND SHOWER CONTROLS SHALL BE LOCATED BETWEEN THE BATHTUB RIM AND GRAB 2 <br /> 06 Oct.2017 Addendum#2 <br /> � �� � �` � � ' � � - � � � -� BAR,AND BETWEEN THE OPEN SIDE OF THE BATHTUB AND MIDPOINT OF THE WIDTH OF THE TUB. <br /> , ;. - - - <br /> � � -- <br /> I GRAB BARS I �. -< _�� I � � _ ;` � o _ _ _ ' _ ', � = c� - � _ � . <br /> N N i , 0 3 16 Oct.2017 Permit Corrections <br /> a � --- �--- - ^ _ __ _ �, _, , <br /> ' <br /> _ 4. PER ANSI 607.6,SHOWER HEAD TO BE ADJUSTABLE HEIGHT, HAND-HELD SHOWER, MOUNTED ON A VERTICAL BAR WfTH 4 26 Jan.2018 Per ' <br /> - ------ - - � , � o � o _, M � � � � � mitCorr ' <br /> MIXING VALVE = A 59"MINIMUM HOSE LENGTH. ection <br /> � I �__ � y. ---. ' \ I � �, u' � _ � <br /> � � -- � � N; --- ' � � � ____ � N � �, 3 0 � o --aM, � THE HAND SHOWER SHALL HAVE A CONTROL WITH A NONPOSITIVE SHUT-OFF FEATURE. - - - - - S <br /> r-� -- <br /> I SHOWER SEAT ``' o "�' M' N I __ __ _ . _ `r� _ - : _ _ _ _ __ <br /> T d'' 3 � , 5. PER ANSI SECTION 1003.12.3.1 AND 1003.12.4.1,ALL REMOVABLE CABINETS MUST BE ABLE TO BE REMOVED WITH <br /> Q REMOVAL OR REPLACEM OUT . <br /> � ENT OF THE COUNTERTOP (WORK SURFACE . FL00 Drawn by. <br /> - ___ ' <br /> ) R FINISH MUST EXTEND UNDER CABINETRY <br /> - --- - _ _ _ _ _ <br /> _ <br /> I PER MFR , �, � -BLOCKING AND � � � --- <br /> _- --\ � __ _ <br /> � GRAB BARS AS N I - AND WALLS BEHIND SURROUNDING CABINETRY MUST BE FINISHED CC/SCIMM <br /> _.._ ._ , <br /> ; ,, '�EQ,p �- \- DOUBLE TOWEL ROBE CLOSET SHELF DOUBLE TOWEL ROBE CLOSET SHELF PAPER TOWEL <br /> � � � . <br /> '�,�_ TOWEL BAR HO O K AND ROD TOWEL BAR HOOK 6. PER ANSI 1003.12.6.4 AND 1003.12.6.5, RANGEIOVEN CONTROLS Checked by(P.M. : <br /> AND ROD DISPENSER SHALL BE LOCATED ON THE FRONT PANELS OF THE - <br /> ) <br /> GRAB BAR BARS BARS APPLIANCE. PROVIDE A WALL SWITCH MOUNTED WITHIN 24"-34"AFF FOR RANGE HOOD CONTROL. CC <br /> -SHOWER SEAT BEGINNING AT <br /> _ - - <br /> MFR THE EDGE OF THE 7. PER ANSI 1003.12.6.6,COMBINATION REFRIGERATOR FREEZERS SHALL HAVE AT LEAST 50 PERCENT OF THE FREEZER Checked by_(Q.C.): <br /> _ _ _ _- - <br /> BELOW 54"AFF. BS�MM <br /> MOUNTING HEIGHTS MOUNTING HEIGHTS - <br /> 3 WALL FACING CONTROL END WALL FACING BACK WALL WALL FACING HEAD END @ TYPE'B'UNITS - <br /> @ TYPE'A'UNITS 8. PER ANSI 1003.12.4.4 AND 1003.12.3.3,WATER SUPPLY AND DRAIN PIPES UNDER SINKS SHALL BE INSULATED OR Project No. <br /> --- <br /> --- - <br /> ONFIGURED TO PROTECT AGAWST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS �G-029A � <br /> 12 T pical Roll-In Shower at T pe 'A' Units & T e 'B' Units 8 , , - - <br /> � � - _ _ _ <br /> Accessory Mounting Heights - Type B 4 Accessor Mountin Hei h LS - T � � 9� PER ANSI 1003.11.6,THE MIRROR PROVIDED ABOVE THE LAVATORY SHALL BE 40"MAX FROM THE BOTTOM EDGE OF <br /> A6.1 Scale: 1/4" = 1'-0° ' <br /> Scale: 1/4�� _ ��-��� � g 9 ype A MIRROR TO THE FLOOR. <br /> A6.1 A6.1 Scale: 1/4" = 1'-0" <br /> 10. IN TYPE'A/UNITS, PER 1003.12.5.5.4 AND 1003.12.5.4.4 CONTROLS OF THE OVEN AND STOVE SHALL NOT REQUIRE A� . � �� <br /> REACHING ACROSS BURNERS. <br /> ■■ � <br />