Laserfiche WebLink
GRID A � <br /> STANDING SEAM _� �� __ (OVERHANG PER ROOF PLAN) _ � , _ OVERHANG PER _ ,_ <br /> METAL ROOFING OVER � � ROOF PLAN � <br /> UNDERLAYMENT ' ���STANDWG SEAM METAL ROOFING � <br /> � g�� OVER UNDERLAYMENT <br /> 6" <br /> � <br /> I � � - �-�%!- S.A. MEMBRANE <br /> RAKE TRIM BY METAL -� �- I �- �. <br /> ROOFING MFR. i � � ��UPTURNED PANEL <br /> � <br /> EDGE(TYP.) ��� �. <br /> �.._.�__ _'���--__---- -- ------ --__---------------- ----------------- __—_ ==� <br /> S.A. MEMBRANE � , � Y — - -" T : � ' . <br /> � � �/ ��I 6 , \ ' � 6 �\ I � <br /> n � � � ,� � . <br /> I�/ �I j� I RAKE TRIM BY METAL � <br /> � �ROOFING MFR. <br /> 5EE DETAIL 1(A7.5 FOR ; I <br /> I � � SEE STRUCT. �' <br /> � I o� FIBER-CEMENT FASCIA I co <br /> _� :I � � DWGS FOR NOTES IN COMMON , , I � 1X6&5/4X8 FIBER CEMENT <br /> I RqKE (RIPPED FROM 5(4X8) I <br /> 1X8&5/4X12 FIBER CEMENT FASCIA OVER '� �' OVERHANG i I � FASCIA OVER BLDG PAPER � <br /> ROOF MEMBRANE-CLAD SHEET METAL � � TYYVEK OR EQ. OVER <br /> BLDG PAPER(TYVEK OR EQ.)OVER � FRAMING 4" � FLUID-APPLIED WRB � � <br /> II FLASHING W/HEMMED EDGE -y � I ' � � STRUCTURAL FASCIA PER <br /> STRUCTURAL FASCIA PER STRUCT. DWGS I � STRUCT. DWGS L; <br /> � '� �2X BLOCKING AS ' T.O. PROTECTION BOARD ' <br /> -� I -\ REQ'D FOR GYP -\-- - - - --�- --�-- <br /> - ,-T-,-r�- , � ;_, , � ; � � , -� I <br /> ��_ � SHEATHING @ GRID LINE � � � � � - - ��� � � � � �� ,�r - _ <br /> C--- II - --- I � �I � <br /> ��� 5112° � ATTACHMENT � � � � ��� �� y <br /> ' CONT.SHEET METAL GUTTER Wl2" - �'' ������� � ` I <br /> T i � ���,\ � DIA. D.S.TO LOWER ROOF � -Ij � � VAPOR , I � • <br /> 1'.0.PLATE � � I <br /> � (ELEV.VARIES) I \ �\ POLYCAR80NATE PANEL � � j � i � RETARDER ' N�-�- " <br /> ��-�««�« ��� CONNECTOR,SPACER+FASTENERS�' I (TYP.) METAL EDGE BEAD �I <br /> � <br /> _� i / _-� �,o„ .- , � I � � BETWEEN EA. BATTEN(TYP.) I�\/ � , < BACKER ROD&SEALANT <br /> ;, ; ; �- 8 (N.T.S.) - ' . <br /> I <br /> SEE DETAILS 5&13/A7.4 � � �� �/ � o POLYCARBONATE � -------- ,�___ L � j I 3 f���� �ik� P�rkin ���� <br /> FOR NOTES IN COMMON �� - PANEL CONNECTOR , 2 _�_ � ' � � <br /> �-----= <br /> � , W BATTEN(BEYOND)�- � ,�r N -------- A7.4 Scale: 3�� = 1�_0�� <br /> � �: <br /> � ; <br /> CONT.VENT PER DET.5/A7.4 " J MULTI-WALL - --- - � � � �a�. � <br /> VENT 1S N(�T REQUIRED WHERE RAKE' FLUID-APPLIED WRB� ; �I pOLYCARBONATE PANEL�--� '_' - ; � PRE-FINISHED ' �Y , <br /> �VERHANG(S 24"Oft LESS � - .. � W �� --- --y� �1 � �� "; �1�\` SHEET METAL -'�--,� I <br /> COMPOSITE FRAMING �+�«a���- 13/16 HIGH CONT. �^x � <br /> SUPPORT SYSTEM GIRT W/1° ' � � UNISTRUT BOLTED TO ,�, `� ^ � � � FLASHING I <br /> � � I <br /> METAL'Z'FURRING TUBE STEEL FRAMING � I i 20 GAUGE --_ � ' <br /> II' WI SOLID STEEL � -� �:„�'�:��.,: CONT.CLEAT �- I <br /> j SPACER CUT TO � � <br /> i I � F I , CLOSED-CELL -.-� -��w't`� j�= � EXTEND ROOFING UNDERLAYMENT UP <br /> MATCH ROOF SLOPE� <br /> 14 STEEL TUBE FRAMING \�- � SPRAY FOAM I� � WALL SHEATHING&BEHWD . <br /> Typic�l ��k� ��tail � � INSUL(2"MIN. i�� F = }i ROOF-TO-WALL FI ASHING AS INUICATED <br /> �� _ � �� PER STRUCT.DWGS�\ � � THICKNESS), I� ; <br /> A7.4 �CaI�; 3 - 1 -0 '�---- � � TYP. � � CONT. PERFORATED'Z"METAL <br /> T.O.SHEATHING @ 2ND FLR I � � `°Z"CLOSURE,APPLY SEALANT @ VERT. LEG <br /> �R��' �- � - - - - - - / - - -- - - - II ;; , � <: <br /> � _ - � II � �� <br /> EE NAL <br /> S L SECTIONS .. <br /> � ) . <br /> I , <br /> � � II ; i + VENTILATED ROOF-TO-WALL ■� `� <br /> _ ____ (OVERHANG PER ROOF PLAN) ALUM.POLYCARBONATE I � � II p � �� �, SHEET METAL FLASHING g� � � <br /> LOW PROFILE PEAK TRIM BY METAL /� „ PANEL CLOSURE � � \ �� _ <br /> ROOFING MFR W/HEMMED EDGES� , � ' -6--____ �NEOPRENE CL05URE BY METAL ROOFWG MFR � _ � I �� r�.L`a�_' •r �� METAL ROOF PANELS OVER UNDERLAYMENT <br /> � � STEEL MOUNTING �- - =�- � � /-�-�_ II �- _� - � � e r�v i ro n rr�e n ta I � <br /> FOLD UP END OF ME7AL ROOFING I (SET IN SEALANT @ BOTTOM&SIDES) � T A B S+C O N N E C T I O N _ __ • <br /> � � ----_ -�---- '- <br /> � � WET-SET �` II � -�_� \ <br /> '-------_ -' PER STRUCT.DWGS I � I MOUNTING � ��'- �`' ---- -- <br /> PANEL&SEAL CORNERS,TYP. <�---__ -_ � , PLATE IN -__ \��' � --_�_ -- __ FLASHING <br /> �_ �2, B L O C K I N G P E R S�f R U C T.D W G S I . ; ��_'�__ <br /> �____ , , ; �_ -�__ __--� - z Communit Desi n Center <br /> C O N T. 1 X P.T.B A C K I N G ���#s ------ @ E A.T R U S S B A Y W/(3)4 1/4' � /�, � � W{�g y g <br /> � � ---�-� -=__--__ WIDEX41/4"DEEP'V'CUTS Q � � �� � - - �-- - _� _�� \_ � � % ,-__^_ ---- � � � PROFILE , <br /> = I _ - _-_ w � \ � SEALANT, � I -- >o <br /> I \ � I ' I� � -(AlRFLO <br /> CONT.5/4X4�'.T. BACKING "' I �' �- �-----__�-_--_- FOR ROOF VENTILATION °' o -� ; � TYP. , � W� \ <br /> w I , I . _ ) 402 15th Avenue East <br /> I �� � WT MOUNTING z v - I � � - �'---_/ �, �- Seattle, Washington 98112 <br /> CONT.CLEAT� � � -_ ------_-- ---__ PLATE& ¢ � M � I � `� _-�- � I 206.329.8300 <br /> i � ---'--- � F-- / I � �: <br /> � �� I � � --___ / 6" 206.329.5494 fax <br /> � CONNECTION w � ��� f � --_____ � ------ � <br /> -� i i� -� ______ --- o r� _� � � � _ { - I �---- MIN f � <br /> PER STRUCT. � � � � � _ �__ -�l V-- � I <br /> � / -----__ - -- ---__ ------- DWGS� � -�� � - � - II �l_ HEMMED EDGE •� , <br /> 1X8&5/4X12 FIBER CEMENT FASCIA � � - -____ _---- -'--- , � _ ( I � � N � TcJP EDGE OF PLYWOOD <br /> OVER BLDG PAPER(TYVEK OR EQ.) �� --- �_ ---- � � r' < � Y-� � SHEATHING TO INCLUDE(3)1 1/2"V�! <br /> -� <br /> 'I ___ --r ---�-�---- <br /> � � `� l--- X 1 1/2"D"V°CUTS PER TRUSS BAY <br /> -'____ - __--�..,,.� - <br /> _ � � � � • <br /> OVER STRUCTURAL FASCIA PER � / _ -----=--- -- � I ' � � � S � , <br /> _ <br /> STRUCT. DWGS I � --__ <- � , 21/4" �% II ��� � � ) ������ <br /> I d- -�_.,--,,-,.- ------- � ! �-- _ � _ <br /> �----_ __ � �_ _--�-"��� � � 2X BLOCKING W! 3 1 1/2" <br /> \ � 1 --_ d- � T.O.PLATE @ 1 ST FLOOR �- ' ' � I II ` --- _ _� I! W X 1 1/2�����V��CUTS <br /> I --_ _ � � <br /> I � _� (SEE WALL SECTIONS) � II I; FLUID-APPLIED WRB ��'�� '��'���� <br /> 8 3/4" <br /> i � `(A1RF1.pw�__`� 3 �-- -� '� - � �i (EXTEND TO B.O. MONO TRUSS) , <br /> i -� „ i -�--- � ��pp�t'�ll�� <br /> , 51/2 <br /> � � ---,�- � 7 Roo�-to-Wall � Tr�llis � V�ntila�ed R��f-t�-W�II Fl�shing H��si�� <br /> iC� I � A7.4 �cale. 3 -- 1 -0 �7,4 Scale. 3 - 1 -0 <br /> �:� <br /> 6200 12th Dr. SE <br /> \- �-'' (J R�D' Everett, WA 98203 . , <br /> -,\-� `'�_j-��rL-�-«-_ _ BLOCKWG PER STRUCT. 12"S.A.MEMBRANE PRE-STRIP � <br /> N � � ��._ DWGS @ EA.TRUSS BAY (WRAP OVER FASCIA AS INDICATED) <br /> � % W/(3)4 1/4"WIDE X 4 1/4" � (OVERHANG PER ROOF PLAN) , 5�Q7 <br /> BACKER ROD&SEALANT � DEEP'V'CUTS FOR % - ----"- - - - � r'� •- e ' <br /> � i ��,.�r�T��R�D <br /> ROOF VENTILATION I SHEET METAL FLASHWG W/HEMMED ��;y��3�-���-� <br /> CONT. METAL EDGE BEAD � -----_ � DRIP EDGE BY METAL ROOFING MFR . <br /> '--------� � <br /> 2X WOOD BLOCKING AS REQ'D - -�--�___, �METAL ROOF PANEL WI HEMMED EDG� <br /> � ---_ __ I ------______ _ CONNECTED TO METAL JOGGLE CLEAT ��.�;����'�J����'�0� � <br /> FOR GYP SNEATHING -� !_�-�'-----___ �_�--- VYILLi�'?�9 f=. Si;�C,� ' <br /> ATTACHMENT �� ".�a « � �_----_ -�',---__ SET IN SEALANT (7YP.} <br /> ; � T.O. RAI S E D H E E L ---�_ ---''�'-- --�---- ---_______- �--,� <br /> ___ - <br /> q � . - - - - - - ---_� ,1- - -- - - <br /> CONT.SOFFIT VENT PER DET. ; (PER WALL SECTIONS) ���- ----_ --- __ �--�_: � #8 WOOD SCREWS-2 PER BRACKET <br /> 5/A7.4(TYP.) � �_ _ ---- � �--- _____ � �_ t: <br /> ....�� -_ �,. -__- <br /> '(AIRF��w�____ � -----�---------�----�� GUTTER SPACER <br /> � - - ___ _' �--,, I ____- � ----------------- s .. <br /> (2)LAYERS 5/8"TYPE'X' _--_� <br /> GYPSUM SHEATHING(TYP.) , �_� �- <br /> �, � <br /> \\ I � � �' I �� N� --------------------------- <br /> �I <br /> _- �0�� ��t�I�S <br /> --__� � —____ � _ _— � . <br /> — -�-- ����� � ��' i <br /> „ i <br /> � � I CONT. PERFORATEDSHEET ' AIRFC��y)\ 1 MIN. _i � _ � r'' --------------------- <br /> � - METAL FLASHING PER DET./ � � � � <br /> 4tA7.1 (TYP.) � �,b�:asa� �,4u�„ _; i <br /> � �� � r- - . <br /> � � 1 1l2"THICK SPRAY FOAM � �� � � <br /> INSULATION � � �' ��� � � <br /> (HT.TO MATCH DEPTH OF 1 112°THIC�SPRAY FOAM � �� � �� � <br /> / -���s ,,��-�� <br /> , , <br /> � � <br /> BLOWN-IN ATTIC INSULATION) INSULATION(HT.TO MATCH - - I %—���_,___ 5 ��2„ �� __ i` _ `_ <br /> - ------------------ <br /> E' <br /> I DEPTH OF BLOINSU ATION - �'� � 1 � _ � _�I--��-�-_ 6" _ I Date • � <br /> _ _ <br /> � } � <br /> � ---___"� � � �I � I g�� ' -------- ---------- �. <br /> �`- �-T--------------_ t z � I " - � �6 J�l i'1 lA� ���� <br /> BLOWN-INATTIC ' � _ �_ I I I � � ' �, --- ----- --�------ <br /> '� I _ �� / �---� I N � ' `� 12 GAUGE GUTTER BRACKET '-0"O.C. . . <br /> BLOWN-IN ATTIC INSULATION , WSULATION(DEPTH - 14) , . s . , �_ � � � @ 3 P��'t1'l!�_t� Cfltl�tf'UC�I��I ��� ' <br /> i � .j, -�`« ' _ - � <br /> �.�« CONT.SNEET METAL GUTTER <br /> � BLOCKING BE7WEEN 7RUSSES& P + � � � �_`�� --� �, N ___________________Revisions <br /> ';� SHEATHING @ TRUSS HEEL PER ; $ � ;, � - _ 1X8&5/4X12 FIBER CEMENT FASCIA OVER <br /> � � 28 July 2017_Bldg._Permit Submittal <br /> � I STRUCT. DWGS } <br /> �� . ���_ CONT. BLDG PAPER(TYVEK OR EQ.)OVER <br /> (2)LAYERS 5/8" STRUCTURAL FASCIA PER STRUCT.DWGS <br /> i TYPE'X'GYPSUM � �\' - - ---- ---- ---- ------ <br /> 1 1/2"THICK SPRAY FOAM ! � � SHEATHING(TYP.) �� i , BACKER ROD&SEALANT 1 28_Sept.2017 Addendum#1 <br /> INSULATION BETWEEN EA.TRUSS �'� 1 1/2"THICK SPRAY FOAM --- <br /> � INSULATION BETWEEN EA.TRUSS�- � � ` �� CONT. METAL EDGE BEAD 2 ___ 06 Oct._2017 Addendum#2 <br /> �: <br /> � �,\ 2X WOOD BLOCKING AS REQ'D FOR 3 1 6 Oc t.2 0 1 7 Permi t Correc tions <br /> � ---- ---- ---- ---- ; .' <br /> BLOCKING BETWEEN TRUSSES& � \ �---_ GYP SHEATHING&D.S.HANGER " - <br /> 4 26 Jan.2018 Permit Corrections <br /> SHEATHING PER STRUCT. DWGS , T.O. PLATE _ _ \ __��l _ _ � � ATTACHMENT <br /> ---- ---- -- ------ <br /> , (PER WALL SECTIONS) � � � CONT. SHEET METAL � � <br /> �v:����.� <br /> � T.O.PLATE _ _ �\ I SOFFITVENTW/15SQ � � -- ------------ ---- <br /> - - - - - - - - I . <br /> � . INOFNETFREEAREA ` �' � ___ _____ ____ ___ Drawnby_ <br /> � � ,. <br /> (PER WALL SECTIONS) r :�,�,�,�.�F.:,���< � � PER LINEAL FOOT I �������� <br /> � � � � --------------------- <br /> COMPOSITE FRAMING SUPPORT SYSTEM � ��,_ � � I \ ���-_-__~� 3/8"S.S. EYEBOLT <br /> � ' � � --_-------- Checked by_(P.M_)_ <br /> GIRT W/1" METAL'Z'FURRING� �, I / �� �- 1/2X2 P1'D WOOD TRIM ,�, <br /> OVER TOP OF TOP PLATEPFOR - r �\ �� <br /> � -� ,, _ � �_�� OVERSOFFITVENT I�Ih„���� �3l8"�S.S. - ----------------- <br /> D.S. HANGEW <br /> FLUID-APPLIED WRB LAPPED OVER TOP OF --,__ AIR BARRIER CONTINUITY --------��� �- NAILING FLANGE COLLAR ;\ THROUGH-BOLT ___________ Checked by_�Q.C_)_ <br /> TOP PLATE FOR AIR BARRIER CONTWUITY � i \ ����� <br /> �----�"��� �. <br /> i COMPOSITE FRAMING � <br /> '--- SUPPOR7 SYSTEM GIRT �- � \ <br /> � �12 GAUGE D.S. __ Pro�ect No_ ; .. <br /> i W/1"METAL'Z'FURRING _-�-� Q�=5°� COLLAWHANGER <br /> ���d��� r <br /> �� �_ -- -------------------- <br /> I I' ---__� _� � COLLAR/HANGER SIDE VIEW <br /> �� 1�ypic�l ��ve ��tail � Truss '� � TYpic�l ��ve ��tail � Tru�s �-_ , � <br /> A7.4 Scale: 3�� = ������ A7.4 Scale: 3�� = 1�_��� <br /> . <br />