My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3001 OAKES AVE 2019-11-07
>
Address Records
>
OAKES AVE
>
3001
>
3001 OAKES AVE 2019-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2019 7:51:55 AM
Creation date
11/7/2019 7:49:07 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3001
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(i©9- Th( <br /> Lighting Summary LGT-SUM <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Info Project Title: Carnegie Building Restoration Date 9/11/2017 <br /> Compliance Applicant Information. Provide contact information for individual who can For Building Department Use <br /> forms do not resoond to inauiries about compliance form information orovided. <br /> require a Company Name: Hargis Engineers Inc <br /> po <br /> useordnstr c Company Address: 1201 3RD AVE SUITE 600,SEATTLE WA 98101 <br /> use Instructional p y <br /> and calculating Applicant Name: PHIL CRAWFORD <br /> cells are <br /> write-protected. Applicant Phone: 206.436.0498 <br /> Applicant Email: PHILIP.CRAWFORD@HARGIS.BIZ <br /> Project Description ❑ New Building 0 Addition 0 Alteration U Plans Included <br /> Include PROJ-SUM form(included in envelope forms workbook)with lighting compliance forms. <br /> Building Additions Compliance Method Interior lighting Exterior lighting <br /> Lighting systems in addition area comply with all applicable ❑ ❑ <br /> Refer to Section C502.2.6 for additional provisions as a stand alone new construction project <br /> requirements. Lighting systems n addition are combined with existing ❑ <br /> building lighting systems to demonstrate compliance <br /> Addition is combined with existing: <br /> For interior lighting projects, include new+existing interior lighting fixture wattage in Proposed Lighting <br /> Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. <br /> For exterior lighting projects,include new+existing exterior lighting fixture wattage in Proposed <br /> Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. <br /> Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting <br /> Lighting Alterations 50%or more of existing are replaced ❑ 0 <br /> Select all Lighting Power and Lighting <br /> Control elements that appy to the sccpe of Less than 50% of existing are replaced ❑ ❑ ❑ <br /> the retroft project If project includes a <br /> combination of spaces where less than Lamp and/or ballast replacement only — ❑ ❑ ❑ <br /> 50%of the existing fixtures are replaced in existing total wattage not increased <br /> some spaces,and 50%or more of the <br /> Fixtures are then 50%or more replaced-Total lighting power of new+existing-to-reman fixtures shall compy with total <br /> provide separatereplacedin others,pewer LPA per Sections C405.4.2 and C405.5.2 Include new+existing-to-remah fixtures in Proposed Lighting <br /> compliance afoams for lightingthe two retroft Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-LCT form. <br /> conditions.Spaces undergoing the same Less than 50%replaced-Total lighting power of new+existing-to-remain fixtures shall not exceed the <br /> type of retroft may be combined into one total lighting power prier to alteration. Include new+existing-to-reman fixtures in the Proposed Lighting <br /> lighting power compliance form. Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-13aform <br /> 50%threshold applies to number of luminaires for interior spaces and parking garages,and total <br /> Refer to Section C503.6 for additional installed wattage for exterior luminaires. <br /> requirements. <br /> Lighting Controls Interior lighting Parking garage Exterior lighting <br /> All alteration lighting controls shall be New wiring installed to serve added <br /> commissioned per C408.3fixtures and/or fixtures relocated to new ❑r ❑ ❑ <br /> ci rcut(s) <br /> New or moved lighting panel ❑ ❑ <br /> Interior space is reconfigured - ❑ <br /> luminaires unchanged or relocated only <br /> New wiring or circuit-For inferior lighting,provide required manual controls per C405.2.3, occupancy <br /> sensor controls per C405.2.1,daylight responswe controls per C405.2.4 and application specify lighting <br /> ❑ No changes are being made to contras per C405.2.5 For exterior lighting,provide required controls per C405.2.7. <br /> the interior or exterior lighting New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> systems and existing space time switch controls per C405.2.2 <br /> uses and configuration are not Reconfigured interiorspace-Provide all required lighting controls that appy to a new interior space. <br /> changed. Application specify lighting control provisions per C405.2.5 do not appy to reconfigured spaces. <br /> Change of Space Use o Existing interior lighting systems n areas under-going achange n space use are upgraded to <br /> conply with LPAs for the new space types per Tables C405.4.2(1)or C405.4.2(2). <br /> Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in <br /> LTG-INT-BLD or LTG-INT-SPACE form <br />
The URL can be used to link to this page
Your browser does not support the video tag.