10/16/2019 City of Everett Page <br /> 11:51:25AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. EW 1703-002 Site Address 3716 ROCKEFELLER AVE <br /> Applied 3/8/2017 Applicant OWNER Lot <br /> Approved 3/8/2017 Owner WILKINSON THOMAS Block <br /> Issued 3/8/2017 Contractor OWNER Tract <br /> Parent Permit No. BW 1611-002 Description ELECTRICAL FOR INTERIOR REMODEL TO EXTG RESIDEN( <br /> Notes SEPARATE PLUMBING,MECH AND ELECTRICAL PERMITS NECESSARY. <br /> Scheduled Completed Tvoe Inspector Result Remarks Inspector's Comments <br /> 11/14/2017 12/21/2018 EXPIRATION KLC Expired permit,14 <br /> LETTER day grace period <br /> 12/21/2017 12/21/2017 ELEC ROUGH IN SKB CORRECTION See notes Make up grounds and pigtail devices. <br /> Strip sheathing in boxes off. <br /> Properly stamp NM cables. <br /> Use fitting on metal J boxes. <br /> Wire must go in J boxes. <br /> Repace broken boxes. <br /> Bond water,gas,etc. <br /> Not ready <br /> 3/6/2018 3/6/2018 ELEC 08-OTHER SKB OTHER See notes Remove microwave from counter receptacle <br /> and dishwasher&disposal. <br /> Not ready. <br /> Close all unused opening-range,laundary <br /> and bathroom receptacles arew to be on <br /> their own circuit. <br /> Bond copper with#4 that are isolated. <br /> Remove all abandoned wiring <br /> Restrap service mast <br /> Land grounds per listing-3 per hole,same <br /> size only. <br /> Add outlets per code 6',12',2',4'. <br /> 3/13/2018 3/13/2018 ELEC 03-ROUGH SKB CORRECTION Run 4 wire Nm to range and ground metal <br /> IN box. <br /> Remove outside receptacle from the <br /> bathroom receptacle circuit. <br /> Laundry circuit has to be dedicated. <br /> Replace damaged basemetn bath wir. <br /> Basement laundry to be dedicated 20 amp <br /> circuit. <br /> 1 neutral conductor per lug. <br /> Water bond to remain accessible. <br /> Install screws in gas bonds. <br /> Not ready <br /> 3/15/2018 3/15/2018 ELEC 03-ROUGH SKB APPROVAL As noted Run independant circuit for the dishwasher <br /> IN and disposal. <br /> The bathroom receptacle cannot have any <br /> other outlets on it. <br /> The refridgerator cannot be on lighting <br /> circuit. <br /> 3/16/2018 3/16/2018 ELEC 03-ROUGH SKB CORRECTION Take the fridge off of the <br /> IN dishwasher/disposal circuit. <br /> The fan wires have to be#12. <br /> 3/19/2018 3/19/2018 ELEC 03-ROUGH SKB CORRECTION No access 9:11 a <br /> IN <br /> 12/26/2018 12/26/2018 ELEC 09-FINAL SKB CORRECTION (12/26/2018 11:59 AM SKB) <br /> All receptacles have to be tamper-resistant <br /> type.No open lamps in closets.Provide <br /> GFCI protection for all kitchen countertop <br /> receptacles and all receptacles within 6 feet <br /> of a sink and in unfinished portions of <br /> basement.Checks hood fan at final. <br /> 12/31/2018 12/31/2018 ELEC 09-FINAL SKB APPROVAL <br /> 12/31/2018 12/31/2018 MARK FINAL** SKB APPROVAL <br /> INSP12 CM/VS YT M <br />