My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2710 WETMORE AVE 2019-11-07
>
Address Records
>
WETMORE AVE
>
2710
>
2710 WETMORE AVE 2019-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2019 11:24:02 AM
Creation date
11/7/2019 11:23:13 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2710
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r y <br /> MAPNET II/TrueAlarm ADDRESSABLE INTERFACE DESCRIPTION <br /> GENERAL <br /> Addressable device communications operate via Tracking this average value as a continuously shifting <br /> Simplex MAPNET II communications. Using a two wire reference point filters out environmental factors that <br /> circuit, individual initiating devices such as automatic cause shifts in sensitivity. <br /> smoke detectors, manual fire alarm stations, TrueAlarm Programmable Sensitivity. The sensitivity of each <br /> smoke sensors, and sprinkler waterflow switches can sensor can be field programmed at the 4020 Control <br /> communicate their exact identity and status. This Panel for different levels of smoke obscuration (in <br /> addressability allows the location and the condition of percent). Sensor sensitivity can be individually varied <br /> each device to be displayed on the 4020 panel LCD automatically by time of day, typically more sensitive at <br /> and on system annunciators.Additionally, NACs night and less sensitive during daytime hours. In order <br /> (horns, bells, strobes, etc.)as well as other control to evaluate whether the sensitivity should be revised, <br /> circuits (fans, dampers, etc.)may also be individually the peak value that is stored in memory can be read <br /> controlled. and compared to the alarm threshold directly in <br /> Capacity.A combined total of 127 addressable monitor percent. <br /> and control devices may be intermixed on the same Diagnostics and Dual Stage Operation.TrueAlarm <br /> common pair of wires. By using Zone Adaptor Modules operation gives the 4020 system the ability to <br /> (ZAMs), conventional initiating devices can be automatically indicate when a sensor is dirty and <br /> connected to the MAPNET II circuit. (Refer to data excessively dirty.The NFPA 72 requirement for a test <br /> sheet S2190-0012 for addressable device information.) of the sensitivity range of the sensors is fulfilled by the <br /> TrueAlarm ability to maintain the sensitivity level of <br /> MAPNET II ADDRESSABLE OPERATION each sensor. Additionally, a"two-stage"alarm <br /> The MAPNET II controller continuously interrogates operation can be programmed in the 4020 panel. For <br /> each addressable device on the communication example, a 1%smoke obscuration reading could cause <br /> channel for status condition such as: normal, a local indication allowing the building security staff to <br /> off-normal, alarm, or trouble. Sophisticated poll and investigate,while a 3%obscuration report could <br /> response communication techniques ensure immediately initiate a system alarm. <br /> supervision integrity and allow for"T-tapping"of the Thermal Sensing.TrueAlarm heat sensors provide <br /> circuit. readings of local temperatures. For fire sensing, rate- <br /> Wiring. Up to 10,000 total feet of twisted, shielded of-rise sensing can be selected as either 15° F(8.3° C) <br /> 18 AWG wire may be connected to the MAPNET II or 20° F (11.1° C)per minute with an independent fixed <br /> channel. The maximum distance from the panel to the limit of 135° F(57°C)or 155° F(68°C). For general <br /> farthest device is limited to 2500 feet. Unshielded wire temperature sensing, a set point can be selected from <br /> may be used in certain retrofit applications. 32°to 158° F (0°to 70°C)and the local temperature <br /> readings can be used to warn of potential problems. <br /> TrueAlarm SYSTEM OPERATION The temperature readings can be programmed to be <br /> MAPNET II can also communicate with TrueAlarm read in either Fahrenheit or Celsius. <br /> smoke density and temperature sensors. Every four <br /> seconds,smoke sensors transmit an output value Data Display.Sensor data can be displayed on the <br /> based on their smoke chamber condition. system LCD,on a remote CRT/keyboard, or printed on <br /> a remote printer. Figure 5 is a sample of a typical <br /> The 4020 CPU maintains a current value, peak value, CRT/keyboard screen when selected for a TrueAlarm <br /> and an average value of each sensor's output. Status is Status Report. <br /> determined by comparing the current sensor value to <br /> its average value. <br /> TIME: 2:42:03 custom title USER: 1 <br /> DATE: WED 03 MAY 00 Port 1 Card 5A ACCESS: 1 <br /> REPORT 3: TRUEALARM STATUS REPORT <br /> Zone Sensi- Almost <br /> Name Custom Label tivity Device Status Dirty <br /> M1-1 ANALOG PHOTO - CLEAN ROOM 0.5 NORMAL <br /> M1-2 ANALOG ION - CLEAN ROOM 1.3 NORMAL <br /> M1-3 ANALOG PHOTO - MAIN LOBBY 2.5 NORMAL *YES* <br /> M1-4 ANALOG PHOTO - CONFERENCE ROOM 1 2.5 NORMAL <br /> M1-10 HEAT DETECTOR - GARAGE 135F NORMAL <br /> M1-il ANALOG PHOTO - KITCHEN 3.7 NORMAL *YES* <br /> Press PF3 for next screen OR PF4 to return to menus <br /> Figure 5.Typical TrueAlarm CRT Status Report Information <br /> S4020-0003-6 6/0 page 5 /;) <br />
The URL can be used to link to this page
Your browser does not support the video tag.