My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2710 WETMORE AVE 2019-11-07
>
Address Records
>
WETMORE AVE
>
2710
>
2710 WETMORE AVE 2019-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2019 11:24:02 AM
Creation date
11/7/2019 11:23:13 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2710
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B®SimplEx Addressable Initiation Peripherals <br /> UL, ULC, CSFM Listed; IDNet and MAPNET II Communicating Devices <br /> FM Approved* Model 4090-9008 Dual Contact Relay IAM <br /> Features <br /> Dual Contact Relay IAM (Individual Addressable 673' O o` <br /> Module): ^; <br /> • A single addressable point provides control and status <br /> tracking of two,2 A Form"C"contacts <br /> ,1 <br /> • Low power latching relay design allows IDNct or � - <br /> F. <br /> MAPNET II communications to supply both data and irt1 <br /> module power 1;01 — <br /> 9 1'01 <br /> • Relay is set to OFF on initial power up and upon loss of 1'01 . 1;©+',1 <br /> IDNet or MAPNET II communications --- <br /> For use with following Simplex control panels: <br /> • Model Series 4007ES,4010ES,4100ES,and 4100U fire <br /> alarm control panels for IDNet communications <br /> • Model Series 4100/4l OOU/4100ES,4120,4020,and <br /> 2120 Communicating Device Transponders(CDTs) 4090-9008 Dual Contact Relay IAM <br /> equipped with MAPNET II communications (shown approximately 1/2 size) <br /> Compact construction: <br /> • Mounts in standard 4"(102 mm)square electrical box, S•ecifications <br /> optional adapter bracket is available to mount in a <br /> 4 I l/6"square electrical box ZDNet or MAPNET II communications, <br /> • Screw terminals for wiring connections Communications 1 address per device <br /> • Visible LED flashes to indicate communications,can be Power Supplied by communications <br /> selected at panel to indicate activated state Installation 579-1040 <br /> • Optional 4"square box covers are available to allow Instructions <br /> LED to be viewed after installation IDNet Firmware Requires 3.12.04 or higher <br /> Contact Ratings*(not rated for incandescent switching) <br /> UL listed to Standard 864 <br /> Dual Form C contacts(DPDT)with <br /> Type terminal block access to Common, <br /> Descri•tion N.O.,and N.0 for each contact <br /> Dual Contact Relay IAMs allow fire alarm control 2 A @ 30 VDC, resistive from listed <br /> panels to control two remotely located Form"C"contact Power Limited e alarm supply <br /> using IDNet or MAPNET II addressable communications <br /> for both data and module power. Typical applications Nonpower Limited 0.5 A @ 125 VAC, resistive <br /> would be for switching local power for control functions Relay Fusing Each contact common is fused with a <br /> such as elevator capture,or control of HVAC components, 2 A fast acting non-time delay fuse <br /> pressurization fans,dampers,etc. Relay status is also * Provide external transient suppression as required per <br /> communicated requiring only one device address. application. DC inductive loads can typically be diode <br /> suppressed; 120 VAC loads may require RC networks or <br /> Product Selection varistors,depending on device type. <br /> Model Description Refer to Installation Instructions for additional information. <br /> 4090-9008 Dual Contact Relay IAM Wire Connections Screw terminals for in/out wiring, z <br /> 18 to 14 AWG wire(0.82 to 2.08 mm2) <br /> Optional Adapter Plates Up to 2500 ft(762 m)from control <br /> Model Description panel <br /> IDNet or <br /> 4090-9813 Adapter plate to fit 4"/i6"(119 mm)square MAPNET II Up to 10,000 ft(3048 m)total wiring <br /> electrical box Communications distance(including T-Taps) <br /> 4090-9801 For semi-flush Optional trim plate for 4" Wiring Reference Compatible with Simplex 2081-9044 <br /> mounted box boxes with LED viewing Overvoltage Protectors <br /> 4090-9802 For surface window, includes mounting 4'/8" H x 4"W x 1 %"D <br /> mounted box screws;galvanized steel Dimensions (105 mm x 102 mm x 35 mm) <br /> Mounting Plate Sheet metal,galvanized <br /> * This product has been approved by the California State Fire Marshal(CSFM)pursuant to <br /> Section 13144.1 of the California Health and Safety Code.See CSFM Listing Temperature 32°to 120° F(0°to 49°C), <br /> 7300-0026:0311 for allowable values and/or conditions concerning material presented in Range intended for indoor operation <br /> this document.Additional listings may be applicable;contact your local Simplex product Humidity Range Up to 93%RH at 100°F(38°C) <br /> supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are <br /> the property of Tyco Fire Protection Products. <br /> S4090-0014-3 11/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.