Laserfiche WebLink
U <br /> � <br /> 10d @ 6"O.C. STUD A5 IZEQ'D <br /> GENERAL STRUCTURAL NOTES (�OOF SHEATHING WINDOW/DOOIZ ^ <br /> C516 911ZAP I'E(Z PLAN, HEADEIZ ( (1 <br /> V J � <br /> TRU55ES PER PLAN NAIL 6TRAP OVER � � <br /> 8d (0.131) @ 6"O.C. 6HEATH TRUSS f'ER 5W-4, �" SHEATHING <br /> ROOF SHEATHING PIZOVIDE INTERMEDIATE J015T PEIZ PLAN WINDOW /DOOR � (�j ' <br /> (THE FOLLOWING TO BE USED UNLESS NOTED OTHERWISE ON THE PLANS) FIZAMING A5 REQUIRED FIZAMING ]� � � <br /> A. GENERAL 10d @ 4 O.C. CS� <br /> 10d @ 4"O.G. ADD C516 STRAP FULL � � � <br /> RAWINGS AND 2 x_A5 iZEQUIRED WIDTH OF SHEAIZ WALL r � � N <br /> A L L M A T E R I A L S, W O R K M A N S H I P, D E S I G N A N D C O N S T R U C T I O N S H A L L C O N F O R M T O T H E D VENtED BLOGKING PLU516°END LENGTH, <br /> v <br /> P I Z O V I D E W E B F I L L E R A 5 7 Y P. � <br /> THE INTERNATIONAL BUILDING CODE (2015 EDITION). CONTRACTOR SHALL VERIFY DIMENSIONS AND H1 @ 24°O.C. KEQUIf�ED V I D E 2 x Z � � <br /> CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO S H�A R W A L L f E K ��� - � <br /> PLAN DETP�I L C BLOCKING BEHIND —� X <br /> C O N S T R U C T I O N. C O N T R A C T O R S H A L L P R O V ID E T E M P O R A R Y B R A C 1 N G F O R T H E S T R U C T U R A L C O M P O N E N T S C516 STIZAP,-n��. _ � <br /> UNTIL ALL F1NAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONTRACTOR (���"��L � _ � O <br /> SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR � z � <br /> PROCEDURES REQUIRED TO PERFORM HIS WORK. STRUCTURAL DESIGN OF THE BUILDING IS BASED ON = <br /> RESISTANCE TO DEAD LOADS, CODE SPECIFIED LATERAL LOADS AND MAXIMUM EXPECTED SERVICE LOADS. D�TA f L B � � � � <br /> NO CONSIDERATION HAS BEEN GIVEN TO LOADS WHICH WILL BE INDUCED BY ERECTION PROCEDURES. ANY � —J —� cS� <br /> PROPOSED FIELD CHANGES AFFECTING THE STRUCTURAL ELEMENTS SHALL BE DISCUSSED WITH THE _ � �' � <br /> ENGINEER OF RECORD PRIOR TO FABRICATION OR CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL �' � � � <br /> ENGINEERING REQUIREMENTS CAN BE 1NSTALLED PER THE ORIGINAL DESIGN PRIOR TO CONSTRUCTION. ' <br /> � Z � �- <br /> SHOULD FIELD CONDITIONS NOT ALLOW THE STRUCTURAL ELEMENTS TO BE INSTALLED PER PLAN, THE EXTEf2101Z WALL � ^ <br /> CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION. w O � N <br /> � � <br /> B. DESIGN CRITERIA (2} �ow5 o�Y4�x4%2� 5�5 N � <br /> SGREWS C�16"O.C. � - <br /> ROOF LIVE LOAD: 25 PSF FLOOR J015T PEf�I'LAN 2 x 6 P.T. DECK J015T PER PLAN <br /> � Q- <br /> ROOF DEAD LOAD: 15 PSF —� <br /> FLOOR LIVE LOAD (RESIDENTIAL): 40 PSF —� <br /> FLOOR DEAD LOAD: 10 PSF � <br /> WIND: SIMPLIFIED METHOD D ETf�I L D � <br /> SPEED: 110 MPH (V ult) � ° <br /> EXPOSURE "B" <br /> � <br /> Kzt = 1.0 ' <br /> SEISMIC: EQUIVALENT LATERAL FORCE PROCEDURE <br /> SPECTRAL RESPONSE ACCELERATIONS: SS = 1.38, Sl = 0.53 <br /> SITE CLASS: D DETAI L 51 <br /> RESPONSE MODIFICATION FACTOR R: 6.5 <br /> ALLOWABLE SOIL BEARING: 1500 PSF <br /> C. CONCRETE <br /> 1. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH (f c) OF AT LEAST 3000 PSI, FOR WEATHERING. THE MIX (2) #�Top (2)#4 T01' Z <br /> SHALL CONTAIN NOT LESS THAN 51/2 SACKS OF CEMENT PER CUBIC YARD. NO SPECIAL INSPECTION IS a � �� ° O <br /> a . <br /> REQUIRED FOR DESIGN BASED UPON 2500 PSI STRENGTH. REINFORCING STEEL SHALL BE DEFORMED BARS -- 4_ � -- <br /> _ d : _ ,� a �� <br /> CONFORMING TO ASTM A615. ALL #4 BARS SHALL BE GRADE 40, fy = 40 KSI. ALL#5 BARS SHALL BE GRADE � a � <br /> °t (2)#4 CONT. � <br /> 6 0, f y = 6 0 K S I. L A P A L L C O N T I N U O U S R E I N F O R C I N G 3 0 B A R D I A M E T E R S O R 2' - 0' M I N IM U M. P R O V I D E �� �� o �d �.. ` a ° I=I�I=I(I d I—I I I—I I I `"'~ <br /> CORNER BARS AT ALL WALL & GRADE BEAM 1NTERSECTIONS. ANCHOR BOLTS TO BE MINIMUM 5/8 DIA J � Q (I 1=1 I I , I I 1=1 I I � <br /> BOLTS EMBED A MINIMUM OF 7". 3°CLEAIZ � a ` . �— I I— #4@ 16°o,c. a. I= I 1= <br /> -�-4 8 —�-4 -� z � <br /> " " " ~ X a .. ° CENTER IN WALL, � <br /> v � ALT. BENDS a a #4@ 16"O.C. � <br /> D. CARPENTRY Q - <br /> Of TION 1 � � ` � .a „ � #4 @ 10'�o.c. <br /> � � _ � #4@10 O.C. a <br /> 1. FRAMING LUMBER SHALL BE GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD GRADING � � � � f1 <br /> RULES FOR WEST COAST LUMBER, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: n da . a � d d v V J <br /> ' STUDS, PLATES & MISC. LT. FRAMING: HEM FIR STD OR BETTER _ _ � _ — � ~~ <br /> � �� 1 Y2'CLEAIZ � <br /> BEAMS AND HEADERS: _— u, z °a ° o — = I I —I I I—I _ a . <br /> D OU G F I R# 2 � � ° � ' A (2) #4 CONT. I I I—I I I aa . . NOTE:SLAB ON GRADE <br /> PSL BEAMS: 2.OE Fb = 2900 PSI ¢ o =I I —I . MUST BE IN PLACE f'I�IOIZ �--- a • �-- <br /> � ; , m TO FULL BAGKFILL OF WALL � p W a #4 J@ 1 6"O.C. � <br /> LSL BEAMS: 1.SSE Fb = 2325 PSI 3��CLEAI� d `� � o <br /> GLB BEAMS: 24F-V4 � � � � � ~ � e '� <br /> JOISTS: 2 x 10 HEM FIR# 2 OR BETTER OR TJI (SEE NOTE 2 BELOW) 4�� 8�� 4�� • ° a � (3)#4 CONT. <br /> °a a ° a 1.L.1 <br /> �OI'TION 2� __ ° FOO71N6 DRAIN <br /> 2. PREFABRICATED WOOD JOIST SHALL BE AS MANUFACTURED BY TRUSS JOIST MACMILLAN CORPORATION ' a — - ' � ° <br /> OR APPROVED EQUAL, JOISTS SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE D�TP�1 L F D1 � ° (2) #4 GONT. � . .,, � <br /> MANUFACTURER'S PUBLISHED SPECIFICATIONS. <br /> a FOOTING DKAIN T <br /> � a �—8 --�—8 —�--8 � 3"GLEAI� <br /> 3. SHEATHING - • �, <br /> o ° �--- <br /> �d a <br /> ROOF SHEATHING: U2" OSB APA RATED SHEATHING (24 / 0). LAY UP WITH MINIMUM 1/8" CLEAR BETWEEN - � <br /> E PLY LIPS AT PANEL EDGES MIDWAY BETWEEN RAFTERS. � D�TP�I L F D�J <br /> PANELS TO ALLOW FOR EXPANSION. PROVID C I I I I <br /> NAILING SHALL BE 8d COMMON (0.131) AT 6" O.C. AT PANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS -�4���-8��-t�-��t- 3��CLEAfZ <br /> UNLESS NOTED OTHERWISE ON THE PLANS. FLOOR SHEATHING: 3l4" CDX T&G MINIMUM APA RATED <br /> PLYWOOD (32 / 16) NAILED AND GLUED. NAILING SHALL BE lOd COMMON (0.148) AT 6" O.C. AT PANEL EDGES DETfi(L �D2 <br /> AND 12" O.C. AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON THE PLANS. PLYWOOD SHALL BE <br /> LAID WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. (2�#a-rop <br /> 4. ALL WOOD PLATES IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE-TREATED. <br /> �,p,� �.5��H�� LP,T�1�f�L D�TP�I L5 <br /> 5. NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS AND OTHER CONNECTING ° t(MIN.) <br /> d I <br /> DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY THE SIMPSON STRONG-TIE , I—I I I—I I( a <br /> COMPANY. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY Q , I I I=I I I � a a <br /> HAVE ICC APPROVAL FOR EQUAL OR GREATER CAPACITIES. VERIFY THAT THE DIMENSIONS OF THE a ° I �I 2'-0�� I � � ° <br /> SUPPORTING MEMBER ARE SUFFICIENT TO RECEIVE THE SPECIFIED FASTENERS. -I— — <br /> a a #4@16"O.G. � —���— . ` � _ <br /> ' „ i�=��� ,° . � - <br /> 6. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: ALL WOOD a #4@ 10 O.G 2'-0 —I I I— <br /> FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE � a ��.�II I I ° FOOTING <br /> a KEINFORCEMENT <br /> INTERNATIONAL BUILDING CODE. MINIMUM NAILING UNLESS OTHERWISE NOTED SHALL CONFORM TO ? TO MATCH FOOTING �I I I I o <br /> TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE. �o a REIN�ORGEMENT,5EE _ a . <br /> � ° 1 Y2'CLEAIZ FOUNDATION WALL =I , a. � °. � a a _ <br /> 7. A L L M E T A L F A S T E N E R S I N C O N T A C T W I T H P R E S S U R E T R E A T E D W O O D S H A L L B E S T A I N L E S S S T E E L O R SECTioNS FOR 5iz� I I I . ` � �. �-- ° � a � 2/2/t$ <br /> � , . AND 5}'ACING �� a . . _ -° - — ° � <br /> — a a. <br /> HOT-DIPPED ZINC COATED GALVANIZED STEEL. a ,� J I :I I I=I =_ _ _ - - ° . F.......WE� <br /> � o � a . #4 J@ 16 O.C. �� �..... <br /> ;����III���ii����=���-��� ���=���—�����I���=) aa d 2'-0 ��'s . �FWAS'y"'i;yl,�, <br /> � o o ° (6) #4 CONT. I 1 I �`�P ������ DATE: 2 / 2 / 18 <br /> r- � o . �1=I a � o'�•. <br /> ° #4 x 3'-6"@ 16"O.G. ���_ ,' a,a 2'-0" 2.� <br /> ° FOOTING DiZAW ���� .. DRAWN BY: MW <br /> . a. . <br /> . . a . ° �'�� WC J P> #: 1 -D <br /> � I I I .Q a a • .''•.•.,�Fc�sg Ep��4:�•�� <br /> o a � Q . — :.... .��S <br /> .. . � a -� ° .. s <br /> d ° a " ....�,, S�y_ <br /> � v a n u I�— . d . ' a <br /> 3 GLEAIZ —���—___°_ — °— <br /> � ��� �� �� ��—���—���—���—���—���—���—��I— <br /> 10 8 2'-6 <br /> _��I=�I I—���-1 I I=1 I I_I I I_ �'' <br /> D ETf�I L F D4 <br /> 5T�P1�ED FOOTING D�TAIL <br /> ORAWING SHEET NO. <br /> S5 OF S5 <br />