GENERAL DOOR NOTES HARDWARE SCHEDULE DOOR SCHEDULE KeYP�a�: <br /> ABBREVIATIONS <br /> 1.ALL NEW DOOR PULL HARDWARE TO BE ACCESSIBLE,APPROVED"LEVER"TYPE, GROUP 1 (DOUBLE DOOR VISION LITE NO RATING) LOCKSET-STORAGE FUNCTION DOOR � FRAME DETAILS SC SOLID CORE,PAINT GRADE PT-10 PAINTED TO MATCH P-10;SEE <br /> MOUNTED AT 36"AFF UON. � � <br /> HC HOLLOW CORE, FINISH SCHEDULE(SHT A6-200) <br /> w t9 PAINT GRADE CL CLEAR ANODIZED ,,�.•� <br /> 4 PAIR BUTT HINGES(SPEC:) m y � w � HM HOLLOW METAL SF SPLIT FINISH <br /> 2.ALL NEW DOORS ARE TO BE 3'-0"WIDE MIN. UNLESS OTHERWISE NOTED. 1 LOCKSET-STORAGE FUNCTION (SPEC:) � W Q � Q a 0 AL ALUMINUM Ex EXISTING '� ` <br /> 1 SET MANUAL FLUSH BOLTS(SPEC:) oC = x Y w = � o w = p m W S/S STAINLESS STEEL EXIR EXISTING REUSED DOOR <br /> 3.ACCESS-CONTROLLED EGRESS DOORS. THE ENTRANCE DOORS IN A MEANS OF EGRESS 2 CLOSER MOUNTED DOOR STOPS(SPEC:) o a c W = a Z � Q Q Z � �-e � G� TEMPERED GLASS (SEE DEMO PLAN) <br /> IN BUILDINGS WITH AN OCCUPANCY GROUP A&B &ENTRANCE DOORS TO TENANT SPACES 2 SURFACE CLOSERS o � 3 x F- ?e � � x � u. x � � COMMENTS Genera�Notes: <br /> All work to be carried out in accadance with the UK Building Regulations,BSI British <br /> IN OCCUPANCIES IN GROUPS A&B THAT ARE EQUIPPED THROUGHOUT WITH AN AUTOMATIC 2 SETS SILENCERS standards,�a�water,Eladriaty regulations and all other relevantAufhorities <br /> SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 907,ARE PERMITTED TO BE EQUIPPED 2 MANUAL KICKDOWN HOLD OPENS(SPEC:) 118 F 4'-6" 9'-91/2" 13/4" SC PT-10 - 3 AL PT-10 7B/A5-400.1 7C/A5-400.1 7B/A5-400.1 requirementc�ncemed. <br /> WHICH SHALL BE INSTALLED IN ACCORDANCE WITH ALL OF THE FOLLOWING CRITERIA. 2 48" STEEL KICKPLATES All wark to be cartied out in a professional 8wwkmanship like manner ac�ording to <br /> 120 C 3'-0" 9'-91/2" 13/4" SC PT-10 - 4 AL PT-10 76/A5�00.1 7C/A5-400.1 76/A5-400.1 the plans 8 speaficatlon. <br /> Do not scale off the drawings unless othervuise stated and use figured dimensions in <br /> 121 C 3'-0" 9'-91/2" 13/4" SC PT-10 - 4 AL PT-10 7B/A5�00.1 7C/A5-400.1 7B/A5-400.1 preference. <br /> 4.A SENSOR SHALL BE PROVIDES ON THE EGRESS SIDE ARRANGED TO DETECT AN GROUP 2 �,SINGLE DOOR NO RATING) LOCKSET-ENTRANCE FUNCTION Ail dimensions are to be checked&verified on site before the oommencernent of any <br /> OCCUPANTAPPROACHING THE DOORS.THE DOORS SHALL BE ARRANGED TO UNLOCK BYA 122 C 3'-0" 9'-91/2" 13/4" SC PT-10 - 4 AL PT-10 76/A5-400.1 7C/A5-400.1 7B/A5-400.1 wo�x,alldimensions&levelsaresubjecttofinalsurveyandset-0ut. <br /> SIGNAL FROM OR LOSS OF POWER TO THE SENSOR. 2 PAIR BUTT HINGES(SPEC:) 123 C 3'-0" 9'-91/2" 13/4" SC PT-10 - 4 AL PT-10 76/A5-400.1 7C/A5-400.1 7BIA5-400.1 This drawing&design is the property of the design group nominated on this shcet <br /> and shouid not be reproduced either in part or whde without the written caisent of <br /> 1 LOCKSET-ENTRANCE FUNCTION (SPEC:) 124 B 3'-0" 9'-91/2" 13/4" SC PT-10 5 AL PT-10 76/A5-400.1 7C/A5-d00.1 7B/A5-400.1 �n�sfi�,. <br /> 5.LOSS OF POWER TO THAT PART OF THE ACCESS CONTROL SYSTEM WHICH LOCKS THE 1 WALL MOUNTED DOOR STOP(SPEC:) 125 C 3'-0" 9'-91/2" 13/4" SC PT-10 - 4 AL PT-10 76/A5-400.1 7C/A5-400.1 7B/A5-400.1 consu�tants: <br /> DOORS SHALL AUTOMATICALLY UNLOCK THE DOORS. 1 SURFACE CLOSER 131 C 3'-0" 9'-91/2" 13/4" SC PT-10 - 6 AL PT-10 7B/A5-400.1 7C/A5-400.1 7B/A5�00.1 <br /> 1 SET SILENCERS <br /> 6.THE DOORS SHALL BE ARRANGED TO UNLOCK FROM A MANUAL UNLOCKING DEVICE 148"STEEL KICKPLATE 132 C 3'-0" 9'-91/2" 1 3/4" SC PT-10 - 7 AL PT-10 7B/A5-400.1 7CIA5-400.1 7B/A5-400.1 <br /> LOCATED 40"TO 48"VERTICALLY ABOVE THE FLOOR&WITHIN 5'-0"OF THE SECURED 133 C 3'-0" 9'-91/2" 1 3/4" SC PT-10 - 7 AL PT-10 7B/A5-400.1 7C/A5-400.1 7B/A5-400.1 <br /> DOORS. READY ACCESS SHALL BE PROVIDED TO THE MANUAL UNLOCKING DEVICE&THE GROUP 3 (PAIR PAINT GRADE DOOR NO RATING) LOCKSET-STORAGE FUNCTION 134A C 3'-0" 9'-91/2" 1 3/4" SC PT-10 - 4 AL PT-10 7B/A5-400.1 7C/A5-400.1 7BIA5-400.1 <br /> DEVICE SHALL BE CLEARLY IDENTIFIED BY A SIGN THAT READS"PUSH TO EXIT'WHEN 134B E T-10" 9'-91/2" 1 3/4" GUAL GUAL - 8 AL AL 1/A5-400.1 2/A5�00.1 1/A5-400.1 <br /> OPERATED,THE MANUAL UNLOCKING DEVICE SHALL RESULT IN DIRECT INTERRUPTION OF 2 PAIR BUTT HINGES(SPEC:) 135 C 3'-0" 9'-9112" 1 3/4" SC PT-10 - 9 AL PT-10 7B1A5-400.1 7C/A5-400.1 7BIA5-400.1 <br /> POWER TO THE LOCK-INDEPENDENT OF THE ACCESS CONTROL SYSTEM ELECTRONICS-& 1 LOCKSET-STORAGE FUNCTION (SPEC:) 136A EX EX EX EX EX SF EX EX EX SF EX EX EX EXISTING DOOR/FRAME TO REMAIN. SPLIT FINISH-FITNESS AREA <br /> THE DOORS SHALL REMAIN UNLOCKED FOR A MINIMUM OF 30 SECONDS. 2 WALL MOUNTED DOOR STOPS(SPEC:) SIDE TO BE PAINTED PT-9, OPP SIDE TO REMAIN EXISTING FINISH <br /> 1 SET MANUAL FLUSH BOLTS, LEAF SIDE(SPEC:) <br /> 7.ACTIVATION OF THE BUILDiNG FIRE ALARM SYSTEM, SHALL AUTOMATICALLY UNLOCK THE 2 SET SILENCERS 136B C 3'-0" 9'-91/2" 1 3/4" SC PT-10 - 9 AL PT-10 7B/A5-400.1 7C/A5-400.1 76/A5-400.1 <br /> DOORS, &THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN 137 EX/R EX/R EX/R EX/R EX/R EX/R - EX/R EX/R SF 7B/A5-400.1 7C/A5-400.1 76/A5-400.1 EXISTING DOOR/FRAME TO REMAIN. SPLIT FINISH-FITNESS AREA <br /> RESET, GROUP 4 (SINGLE DOOR NO RATING)NON-LOCKING SIDE TO BE PAINTED PT-9, OPP SIDE TO REMAIN EXISTING FINISH <br /> 2 PAIR BUTT HINGES SPEC 138 EX EX EX EX EX SF EX EX EX SF EX EX EX EXISTING DOOR/FRAME TO REMAIN. SPLIT FINISH-FITNESS AREA <br /> 8.ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER OR FIRE DETECTION SYSTEM, ( ) SIDE TO BE PAINTED PT-10, OPP SIDE TO REMAIN EXISTING FINISH <br /> SHALL AUTOMATICALLY UNLOCK THE DOORS.THE DOORS SHALL REMAIN UNLOCKED UNTIL 1 LATCHSET (SPEC:) :139 EX EX EX EX EX SF EX EX EX EX EX EX EX EXISTING DOOR/FRAME TO REMAIN. SPLIT FINISH-HALL SIDE TO <br /> THE FIRE ALARM SYSTEM HAS BEEN RESET. 1 HEADER MOUNTED DOOR STOP(SPEC:) BE PAINTED PT-1, OPP SIDE TO REMAIN EXISTING FINISH <br /> 1 SET SILENCERS <br /> 9.ENTRANCE DOORS IN BUILDINGS WITH AN OCCUPANCY IN GROUP A, B SHALL NOT BE 140 EX EX EX EX EX SF EX EX EX EX EX EX EX EXISTING DOOR/FRAME TO REMAIN. SPLIT FINISH-HALL SIDE TO <br /> SECURED FROM THE EGRESS SIDE DURING PERIODS THAT THE BUILDING IS OPEN TO THE GROUP 5 �SINGLE PAINT GRADE DOOR NO RATING) LOCKSET-STORAGE FUNCTION BE PAINTED PT-1, OPP SIDE TO REMAIN EXISTING FINISH <br /> GENERAL PUBLIC. <br /> 2 PAIR BUTT HINGES(SPEC:) <br /> 10. ALL STUDS AT DOOR FRAMES TO BE ST10 TYPE. 1 LOCKSET-STORAGE FUNCTION (SPEC:) <br /> 1 WALL MOUNTED DOOR STOPS(SPEC:) <br /> 11. THE GENERAL CONTRACTOR SHALL PROVIDE&INSTALL REQUIRED BUCKS& 1 SET SILENCERS <br /> ASSEMBLIES AS SHOWN ON UNISPACE. DRAWINGS UNLESS OTHERWISE NOTED. <br /> GROUP 6 (SINGLE PAINT GRADE DOOR NO RATING)THUMB TURN DEADBOLT <br /> 12. THE GENERAL CONTRACTOR SHALL PROVIDE& INSTALL DOORS AS SPECIFIED ON <br /> UNISPACE DRAWINGS UNLESS OTHERWISE NOTED. 1 THUMB TURN DEADBOLT WITH OCCUPANCY INDICATOR(SPEC.) <br /> 1 LEVER LATCH SET(SPEC:) <br /> 13. ALL LOCK SETS SHALL BE CODED&/OR KEYED IN ACCORDANCE WITH THE BUILDING 2 PAIR BUTT HINGES(SPEC:) <br /> REQUIREMENTS. CODES&/OR KEYS ARE TO BE DELIVERED TO TENANT PROPERLY TESTED 1 WALL MOUNTED DOOR STOPS(SPEC:) <br /> &/OR TAGGED.THE NUMBER OF MASTER&PASS KEYS SHALL BE COORDINATED WITH 1 SET SILENCERS <br /> BUILDING MANAGEMENT. <br /> GROUP 7 (SINGLE PAINT GRADE DOOR NO RATING)CIPHER LOCK <br /> 14. DETAILED DOOR&HARDWARE SCHEDULES SHALL BE SUBMITTED TO UNISPACE. FOR <br /> REVIEW, &FABRICATION OF MATERIAL SHALL NOT BE COMMENCED UNTIL SUCH REVIEW 1 CIPHER LOCK(SPEC:) <br /> HAS BEEN RETURNED. 1 LEVER LATCH SET(SPEC:) <br /> 2 PAIR BUTT HINGES(SPEC:) <br /> 15. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR 1 WALL MOUNTED DOOR STOPS(SPEC:) <br /> DOORS&5 POUNDS FOR INTERIOR DOORS, SUCH PULL/PUSH EFFORT BEING APPLIED AT 1 SET SILENCERS <br /> RIGHT ANGLES TO HINGED DOORS &AT THE CENTER PLANE OF THE SLIDING OR FOLDING <br /> DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO GROUP 8(DOUBLE SLIDING GUAL DOOR) PASSAGE SET <br /> MEET THE ABOVE STANDARD.WHEN FIRE DOORS ARE REQUIRED,THE MAXIMUM EFFORT <br /> TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE 1 HEAVY DUTY OVERHEAD BARN DOOR TRACK WITH MFR BARNDOOR HARDWARE <br /> APPROPRfATE ADMINISTRATIVE, NOT TO EXCEED 15 POUNDS. 4 LADDER PULLS(SPEC:) <br /> INTEGRAL SOUND AND SEAL SWEEPS <br /> 16. THE BOTTOM 10"OF ALL DOORS(EXCEPT SLIDING&AUTOMATIC)SHALL HAVE A <br /> SMOOTH UNINTERRUPTED SURFACE. GROUP 9 jSINGLE DOOR NO RATING)PANIC HARDWARE <br /> 17. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32"CLEAR OPENING WITH THE 2 PAIR BUTT HINGES(SPEC:) <br /> DOOR AT 90 DEGREES TO THE CLOSED POSITION. 1 PANIC HARDWARE FROM INTERIOR WITH ACTIVATION ALARM(SPEC:) <br /> 1 CLOSER(SPEC:) <br /> 18. ONE OF A PAIR OF DOORS SHALL MEET THE MINIMUM WIDTH REQUIREMENTS. 1 SET SILENCERS <br /> NO HARDWARE AT EXTERIOR <br /> 19. MAXIMUM HEIGHT OF THRESHOLD TO BE 1/2" MAXIMUM VERTICAL CHANGE AT EDGE IS <br /> 1/4"WITH A MAXIMUM BEVEL OF 45 DEGREES. GROUP 10 fSINGLE PAINT GRADE DOOR NO RATING)STAINELSS STEEL PUSH PLATE, PULL HANDLE <br /> 20. LATCHING&LOCKING DOOR THAT ARE HAND ACTIVATED&WHICH ARE IN THE PATH OF STAINLESS STEEL PUSH PLATE AND PULL <br /> TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC 2 PAIR BUTT HINGES(SPEC:) <br /> BARS, PUSH PULL ACTIVATING BARS, OR BARS OR OTHER HARDWARE DESIGNED TO ' 1 CLOSER(SPEC:) <br /> PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 1 CLOSER MOUNTED DOOR STOP(SPEC:) <br /> STAINLESS STEEL KICKPLATE 18° <br /> 21. SEE SHEET A9-00 FOR REQUIREMENTS OF DOORS,WINDOWS, &HARDWARE, I.E. DOOR 1 SET SILENCERS <br /> SCHEDULE, HARDWARE SCHEDULE, EQUIPMENT SCHEDULE, FIXTURE SCHEDUE&DOOR& <br /> WINDOW DETAILS. <br /> 22. TYPICAL DOORS CONVENTIONS ARE AS FOLLOWS: <br /> DIMENSIONS TO EDGE OF DOOR LOCATING DOOR OPENINGS ARE TO WSIDE FACE OF <br /> JAMB, UNLESS OTHERWISE NOTED. <br /> 23. DOOR OPENINGS ARE TO BE LOCATED SO THAT INSIDE FACE OF BUTT SIDE JAMB IS 4" <br /> FROM FACE OF PERPENDICULAR WALL AT CORNER,ALLOWING FOR A 90 DEGREE SWING <br /> TYPICAL, UNLESS OTHERWISE NOTED. <br /> 24. SEE SHEET A9-00 FOR SPECIFIC DOOR REQUIREMENTS. ' <br /> ', 10123 <br /> 25. UNDERCUT BUILDING STANDARD INTERIOR DOORS AS REQUIRED TO CLEAR FINISHED ' R�azsTERED <br /> FLOOR BY 114". ALL RATED DOORS SHALL BE ORDERED SO AS TO CLEAR THE FINISHED ' ARcxiT$c�r <br /> FLOOR BY 114", UNLESS OTHERWISE NOTED. � � ' <br /> r 10/03/201 <br /> r �'� <br /> 26. ANY GLAZING ON OR WITHIN 24"OF A DOOR(IN THE SAME PLACE)SHALL BE TEMPERED �' �' noxx DE vo� <br /> OR APPROVED EQUAL, SECTION 2406.4&2406.6. STATE OF WASHINGTON <br /> PERMIT SET 10/03/16 <br /> DOOR AND FRAME TYPES REV DESCRIPTION DATE BY CHK <br /> ; �.� �� <br /> SEE DOOR SCHEDULE SEE DOOR SCHEDULE SEE DOOR SCHEDULE SEE DOOR SCHEDULE <br /> ' 701 5th Ave., Suite 6730 <br /> ' ,,.__ Seattle WA 98104 USA <br /> ' +1 206 270 7000 <br /> ; ' www.unispace.com <br /> ' = x x = <br /> C9 C9 C9 (7 ' Client/Project Name/Address: <br /> " W 111 W W <br /> 2 2 2 S <br /> � J J J J <br /> J J J J <br /> LL LL LL LL. <br /> �°��ERE° FLUKE CAFE/FITNESS <br /> ' INSERT ' <br /> � <br /> '; -- 6920 Seaway Blvd, Everett,WA 98203 � <br /> � <br /> � <br /> Y <br /> TYPE A TYPE B TYPE C TYPE D ' <br /> HOLLOW CORE SOLID CORE PAINT SOLID CORE PAINT SOLID CORE PAINT �, <br /> METAL DOOR GRADE DOOR GRADE DOOR GRADE DOOR Drawing Title: � <br /> VISION LITE <br /> LL <br /> DOOR AND �� <br /> : � <br /> ; <br /> ,,_6„ 3,_o.. HARDWARE �� <br /> SEE DOOR SCHEDULE <br /> ' �� SCHEDULES � <br /> � <br /> � <br /> 0 <br /> � � Stat�: permit Set � <br /> � <br /> _ = Drawn By: KSR/IH Checked By:DD � <br /> ? ? sca►e: As indicated Date: 10I03/16 � <br /> � � Project Number: <br /> WD064 � <br /> 0 <br /> � <br /> Drawing Number: Revision: a <br /> � <br /> 0 <br /> TYPE E TYPE F o <br /> DOUBLE SLIDING FRAMED SOLID CORE PAINT � � <br /> GLASS DOORS GRADE DOOR ■ W <br /> � <br /> z <br /> _ _ _ . . . , . _ _ _ . . ' a <br />