GENERAL CONSTRUCTION NOTES s�
<br /> ., lal'�I� C�?
<br /> 1.ALL CONSTRUCTION SHALL COMPLY WITH THE(2Q1518C WITH WAC 51-50,2015 IEBC WITH WAC DIMENSION: ADDITIONAL GENERAL CONTRACTOR RESPONSIBILITY: 1.THE GENERAL CONTRACTOR SHALL PROVIDE SUBMITTALS FOR REVIEW&APPROVAL BY
<br /> 51-50.AND WAC 51-11),AND ALL APPLICABLE LOCAL CODES,ORDINANCES,AND STANDARDS. 1.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN 1.GENERAL CONTRACTOR IS RESPONSIBLE TO PROVIDE FINAL AS BUILT DRAWINGS INCLUDING UNISPACE.G.C. IS TO PROVIDE TWO SAMPLES OF THE SPECIFIED MATERIALS.SUBMITTALS 701 5th Ave., Suite 6730
<br /> IN CASE OF ANY CONFLICT WHERE THE METNODS OR STANDARDS OF INSTALLATION OF THE AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUAR,4NTEE OF ACCURACY.DO NOT ARCHITECTURAL,MECHANICAL,ELECTRICAL,PLUMBING AND LIFE SAFETY TO CLIENT IN FINAL SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING:DRAW DOWNS OF ALL PAINTS, Seattle WA 98104 USA
<br /> MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OF SCALE DRAWINGS.THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND CLOSE OUT DOCUMENTS. SAMPLES OF ALL CARPETS,ALL SPECIFIED FLOOR BASE,SAMPLES OF ALL WALL FINISHES, +1 206 270 7000
<br /> ORDINANCES,THE LAWS OR ORDINANCES SHALL GOVERN.NOTIFY THE ARCHITECT OF ALL DIMENSIONS AND SHALL NOTIFY UNISPACE OF ANY DISCREPANCIES OR CONDITIONS OR 2.THE CONTRACTOR WiLL INSPECT THE PREMISES IMMEDIATELY TO CHECK EXISTING WORKING SAMPLES OF SPECIFIED CABINET FINISHES,SAMPLES OF CEILING GRID&CEILING TILE, www.unispace.com
<br /> CONFLICTS. CONDITIONS ADVERSELY EFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. CONDITIONS.SHOULD THE CONTRACTOR FIND CONDITIONS WHICH HE/SHE BELIEVES WOULD PACKAGES OF LIGHTING SUBMITTALS,DOOR&HARDWARE,MILLWORK SHOP DRAWWGS,
<br /> 2.THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF THE 2.DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISH GWB IMPEDE HIS/HER WORK,THEN SUCH CONDITIONS MUST BE REPORTED IMMEDIATELY TO THE MILLWORK HARDWARE SUBMITTALS,ETC.PROVIDE(3)12"X12"WOOD VENEER SUBMITTALS.
<br /> ARCHITECT OF RECORD AND SHALL NOT BE REPRODUCED OR USED FOR ANY OTHER PURPOSE FACE OF PARTITIONS,UNLESS NOTED OTHERWISE.DOOR CASED OPENINGS WITHOUT OWNER. FAILURE TO SO ADVISE WILL CONSTITUTE NOTICE THAT THE CONTRACTOR IS FULLY 2.THE GENERAL CONTRACTOR SHALL INCLUDE IN HISIHER ESTIMATE ALL COSTS,(INCLUDING Consultants:
<br /> EXCEPT BY WRITTEN AGREEMENT. LOCATION DIMENSIONS ARE TO BE FOUR(4j INCHES FROM THE FACE OF THE ADJACENT SATISFIED WITH THE EXISTING CONDITIONS AND THAT HE/SHE INTENDS TO PERFORM HIS/HER OVERTIME WORK)FOR REMOVAL,NEW INSTALLATION&REINSTALLATION WORK FOR ANY
<br /> 3.SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE,CONSTRUCTION,LABOR, PARTITION OR CENTERED BETWEEN PARTITIONS. OBLIGATIONS WITH NO ALLOWANCE EITHER IN TIME OR MONEY FOR ANY IMPEDIMENTS TO THIS PLUMBING,CEILING(TAKE-DOWN&REINSTALLATION),ELECTRICAL,TELEPHONE
<br /> HEALTH AND LICENSING.CONTRACTOR SHALL FURTHER POST ALL BONDS AND SECURE ALL 3.ALL ANGLES ARE AT 90 OR 45 DEGREES UON. WORK. COMMUNICATIONS EQUIPMENT OR HVAC WORK ON CEILING PLENUM.
<br /> INSURANCE REQUIRED BY LAW OR CONTRACT,FORWARDING PROOF OR SUCH ACTIONS TO 3.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HISIHER BEST SKILL AND 3.THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT&COMPLETE SET OF CONSTRUCTION
<br /> THE LANDLORD PRIOR TO COMMENCEMENT OF CONSTRUCTION. CONSTRUCTION: ATTENTION.HE/SHE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION,AND/OR DRAWINGS ON SITE DURING ALL PHASES OF CONSTRUCTION FOR USE BY ALL TRADES.
<br /> 4.WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED"N.I.C."OR SPECIFICALLY 1.GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT ABOUT SITE CONDITIONS THAT REQUIRE INSTALLATION MEANS,METHODS,TECHNIQUES,SEQUENCES OR PROCEDURES AND FOR 4.ALL EXISTING APPURTENANCES NOT BEING REMOVED SHALL BE REFURBISHED WHERE
<br /> ASSIGNED TO ANOTHER PARTY. ADDITIONAL INTERIOR WALLS SUPPORT OR STRUCTURAL DETAILS. COORDINATING ALL PORTIONS OF THE WORK UNDER THIS CONTRACT. REQUIRED.ANY LOOSE ITEMS TIGHTENED(CEILING EXIT SIGNS,ETC.)&ANY MISSING PARTS
<br /> 5.CONTRACTORS SHALL VISIT SITE, REVIEW THE DRAWINGS AS SUBMITTED BY THE ARCHITECT, 2.INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL,PLUMBING,MECHANICAL, 4.ALL WORK SHALL BE EXECUTED IN A NEAT AND WORKMANLIKE MANNER ACCEPTABLE TO THE REPLACED BY THE GENERAL CONTRACTOR TO ACHIEVE A FINISHED FIRST CLASS INSTALLATION
<br /> AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE OWNER. &APPEARANCE.
<br /> CONSTRUCTION. ARCHITECT OF NAY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 5.UNLESS OTHERWISE SPECIFICALLY NOTED,THE CONTRACTOR SHALL PROVIDE AND PAY FOR 5.ALL REQUIRED EXITS,WAYS OF APPROACH THERETO,&WAYS OF TRAVEL FROM THE EXIT INTO
<br /> 6.ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST 3.COORDINATE CONSTRUCTION SCHEDULING WITH BUILDING OWNER TO ALLOW ONGOING ALL LABOR,MATERIALS,EQUIPMENT,TOOLS,CONSTRUCTION EQUIPMENT,AND MACHINERY, THE STREET SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL OBSTRUCTIONS&
<br /> RECOMMENDATIONS OR WRITTEN DIRECTIONS. OPERATION OF THE FACILITY DURING CONSTRUCTION. TRANSPORTATION,OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION OF IMPEDIMENTS FOR UNOBSTRUCTED EGRESS IN THE CASE OF FIRE OR OTHER EMERGENCY.
<br /> 7.WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, 4.PROVIDE BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. THE COMPLETION OF THE WORK.THE CONTRACTOR WARRANTS TO THE OWNER AND BUILDING DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION,ALL EXISTING EXITS,EXIT
<br /> THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 5.OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. MANAGEMENT THAT ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THIS CONTRACT WILL LIGHTING,FIRE PROTECTIVE DEVICES AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
<br /> 8.WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS 6.PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. BE NEW UNLESS OTHERWISE SPECIFIED,AND THAT ALL WORK WILL BE GOOD QUALITY,FREE 6.EACH CONTRACTOR SHALL MAKE ALL REQUIRED ARRANGEMENTS FOR DELIVERY OF
<br /> INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE 7.PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. EQUIPMENT&/OR MATERIALS. IT SHRLL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO
<br /> REQUIRED TO PROPERLY COMPLETE THE WORK. CONSTRUCTION TO RECEIVE NEW SCHEDULE FINISHES.ALL SURFACES ARE TO HAVE"LIKE- ALL WORK NOT SO CONFORMING TO THESE STANDARDS MAY BE CONSIDERED DEFECTIVE. IT CHECK THE RULES®ULATIONS GOVERNING WORK ON THE PREMISES, INCLUDING THE
<br /> 9.VERIFY ALL"BUILDING STANDARDS"WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. NEW"APPEARANCE. IS UNDERSTOOD THAT NO INFERIOR OR NON-CONFORMING WORK OF THE MATERIALS WILL BE FOLLOWING:
<br /> HOWEVER,THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS 8.STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE IN ACCEPTED WHETHER DISCOVERED AT THE TIME THEY ARE INCORPORATED IN THE WORK OR A. DATE&TIME OR DELIVERY SHALL BE ESTABLISHED IN CONJUNCTION WITH THE
<br /> WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF.THE CONTRACTOR AGREES TO COMPLIANCE WITH ASTM C 754 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL AT ANY TIME BEFORE OR AFTER THE FINAL ACCEPTANCE. IF REQUIRED BY THE OWNER,THE PERSON HAVING JURISDICTION OVER PREMISES. OVERTIME CHARGES&IOR ANY
<br /> DEFEND, INDEMNIFY,AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A LOADING REQUIREMENTS. CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND INSTALLATION NECESSARY EXPENSE SHALL BE PAID BY CONTRACTOR REQUIRING SERVICE.
<br /> RESULT OF UNAPPROVED CHANGES. 9.ALL DEMOLISHED MATERIALS TO BE RECYCLED BY AN APPROVED RECYCLER. OF MATERIALS AND EQUIPMENT. B. BUILDING CONDITIONS, INCLUDING SIZE&LOADING CAPACITY OF ELEVATORS,SIZE OF
<br /> 10.LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM 6.THE WARRANTIES AND GUARANTEES PROVIDED IN THE CONSTRUCTION DOCUMENTS SHALL BE DOORWAYS,CORRIDORS,WINDOW OPENINGS,ETC.,SHALL BE CHECKED BY THE
<br /> FROM DAMAGE.THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT LIFE SAFETY: IN ADDITION TO AND NOT IN LIMITATION OF ANY OTHER WARRANTY AND GUARANTY OR REMEDY CONTRACTOR BEFORE DELIVERY TO ASSURE ITEMS WILL FIT INTO SPACE.
<br /> OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE 1.IF NECESSARY,PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED REQUIRED BY LAW OR THE CONSTRUCTION DOCUMENTS. C. ALL CHARGES INVOLVING THE INSTALLATION&lOR OPERATION OF A HOIST SYSTEM, IF
<br /> EXECUTION OF THIS WORK. ELEMENTS AS REQUIRED BY CODE. 7.ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER COMPLETION REQUIRED,SHALL BE BORNE BY THE CONTRACTOR USING THE SYSTEM.CHARGES
<br /> 11.VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS 2.FIRE EXTINGUISHERS:VERIFY LOCATION,TYPE,AND SIZE PER FIRE MARSHAL UNLESS OTHERWISE SPECIFIED,AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN INVOLVING THE TEMPORARY REMOVAL&REINSTALLATION OF WINDOW SASH&/OR
<br /> OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS. REQUIREMENTS.CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE PROPOSAL AGREEMENT.ALL REPAIRS,CORRECTIONS,DISCREPANCIES,ETC.,MUST BE MADE FIXED PANELS REQUIRED FOR DELIVERY SHALL BE BORNE BY THE CONTRACTOR.
<br /> 12.ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN EXTINGUISHERS REQUIRED UNDER N.F.P.A. 10 MOST RECENT EDITION AND APPROVED BY WITHOUT ANY ADDITIONAL GOST TO THE OWNER,AND WITHIN FIVE(5)DAYS AFTER NOTICE IS 26.THE GENERAL CONTRACTOR,SUBCONTRACTOR&TENANTS CONTRACTOR SHALL SUBMIT
<br /> CONDITION AT ALL TIMES. THE FIRE MARSHAL.CONFIRM ACCESSIBILITY OF LOCATION WITH FIRE ALARM PRIOR TO GIVEN. CERTIFICATES TO THE BUILDING MANAGER&OWNER UPON COMPLETION OF WORK, INCLUDING
<br /> 13.PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. INSTALLATION.PROVIDE FINISHED CABINETS TO MATCH BUILDING STANDARD FOR 8.THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL NOT HAVE ANY RESPONSIBILITY BUT NOT LIMITED TO THE FOLLOWING:
<br /> 14.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN EXTINGUISHERS AT ALL EXPOSED LOCATIONS. FOR THE DISCOVERY, PRESENCE,HANDLING,REMOVAL OR DISPOSAL OF OR EXPOSURE OF A. FIREPROOF WOOD TEST REPORT(IF REQUIRED).
<br /> ACCORDANCE WITH ALL APPLICABLE SAFETY CODES. 3.FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED SO THAT THE TOP OF THE PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING,BUT B. ELECTRICAL,PLUMBING&AIR CONDITIONING CERTIFICATES ISSUED BY:
<br /> 15.THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING OWNER/ARCHITECT/ENGINEER EXTINGUISHER OR CABINET IS NO HIGHER THAN 48"AFF AND THE TOP OF THE NOT LIMITED TO ASBESTOS PRODUCTS,POLYCHLORINATED BIPHENYL(PCB)OR OTHER TOXIC -DEPARTMENT OF WATER SUPPLY,GAS&E�ECTRICITY
<br /> HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE PROPERTY CAUSED BY THE EXTINGUISHER OR CABINET HANDLE IS AT LEAST 36"AFF. SUBSTANCES. -BOARD OF FIRE UNDERWRITERS
<br /> NEGLIGENCE OF THE CONTRACTOR,HIS/HER AGENTS,EMPLOYEES,OR SUBCONTRACTORS. 4.AT SEMI-RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYER(S)OF TYPE 9.THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION,STANDARDS FORM OF
<br /> 16.APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS. 'X'GYPSUM WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED THE AMERICAN INSTITUTE OF ARCHITECTS,CURRENT EDITION,SHALL APPLY TO AL�WORK IN
<br /> ALL CQNSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REQUIREMENT.REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. THIS CONTRACT,EXCEPT AS SPECIFICALLY MODIFIED BELOW&/OR BY THE AGREEMENT.
<br /> REVISIONS,ADDENDA,AND CHANGE ORDERS.THE CONTRACTOR SHALL ALSO MAINTAIN IN 5.PROVIDE AND INSTALL FIRE EXTtNGUISHER SIGNAGE(5"X6")ABOVE EACH FIRE 10.PRIOR TO BEGINNING ANY WORK THE GENERAL CONTRACTOR SHALL FURNISH A
<br /> GOOD CONDITION,ONE COMPLETE SET OF PLANS WITH ALL REVISIONS,ADDENDA,AND EXTINGUISHER OR CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. CONSTRUCTION SCHEDULE SHOWING THE CHRONOLOGICAL PHASE OF HIS/HER WORK &ALL
<br /> CHANGE ORDER,ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. RELATED WORK FOR THE COMPLETION OF THE PROJECT.THIS SCHEDULE SHALL INDICATE ALL
<br /> JOB SUPERINTENDENT. 6.EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 201518C WITH WAC 51-50& ORDERING LEAD TIMES,LENGTH OF TIME FOR EACH PHASE, ITS START&COMPLETION,WITH A
<br /> 17.PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOB IS IN PROGRESS AND UNTIL 20151EBC WITH WAC 51-50 AND EVERETT FIRE MARSHALL REQUIREMENTS.CONTRACTOR PROJECTED COMPLETION DATE.
<br /> THE JOB IS COMPLETE. TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND EXIT LIGHTING AS REQUIRED BY THE 11.ALL UNISPACE DRAWINGS&ALL CONSTRUCTION NOTES ARE COMPLEMENTARY,& WHAT IS
<br /> 18.AT COMPLETION OF THE WORK,REMOVE ALL DEBRIS FROM THE SITE,LEAVING SPACE C�EAN, EVERETT FIRE AND BUILDING DEPARTMENTS.CONFIRM ACCEPTABILITY OF LOCATIONS CALLED FOR BY EITHER WILL BE BIND►NG AS IF CALLED FOR BY ALL.ANY WORK SHOWN OR
<br /> WASH ALL WINDOWS AND GLASS,POLISH ALL HARDWARE AND FIXTURES.REPLACE AND PATCH WITH FIRE MARSHAL BEFORE INSTALLATION.CONTRACTOR SHALL PROVIDE AND INSTALL REFERRED TO ON ANY ONE SET OF DRAWINGS SHALL BE PROVIDED AS THOUGH SHOWN ON
<br /> AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. AUDIBLE ALARMS IN ACCORDANCE WITH(201516C W/TH WAC 51-50&2015/EBC WITH WAC ALL RELATED DRAWINGS.
<br /> 19.MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE,ODOR,FUMES,OR VIBRATION. 51_50).CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE 12.BEFORE SUBMITTING A PROPOSAL,ALL CONTRACTORS SHALL VISIT THE PREMISES,
<br /> AT THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS DETECTION AS REQUIRED UNDER CHAPTER 7 OF THE(20151BC WITH WAC 51-50&2015/EBC FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS&SATISFY THEMSELVES AS TO THE
<br /> SOILED BY CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO WORK WAS DONE. WITH WAC 51-50).THE INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL INCLUDE THE NATURE&SCOPE OF THE WORK&THE DIFFICULTIES THAT ATTEND TO ITS EXECUTION. THE
<br /> 20.LATHING,PLASTER,AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 CONNECTION TO AND/OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS,AS SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH AN
<br /> OF THE INTERNATIONAL BUILDING CODE. NECESSARY. EXAMINATION HAS BEEN MADE&LATER CLAIMS FOR LABOR,EQUIPMENT,OR MATERIAL
<br /> 21.ALL GLASS AND GLAZING SHALL COMPLY WITH THE(2Q95(BC WITH WAC 51-50&20151EBC 7.EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY REQUIRED FOR DIFFICULTIES ENCOUNTERED,WHICH COULD HAVE BEEN FORESEEN HAD SUCH
<br /> W/TH WAC 51-50) AND THE U.S. PRODUCT SAFETY COMMISSION:SAFETY STANDARDS FOR SPECIAL KNOWLEDGE OR EFFORT. AN EXAMINATION BEEN MADE,WILL NOT BE RECOGNIZED.
<br /> ARCHITECTURAL GLAZING MATERIALS(42 FR 1426:16 CFR PART 1201). 8.FLAMMABLE LIQUIDS SHAL�NOT BE PLACED,STORED,OR DISPENSED IN THIS OCCUPANCY 13.ALL CONTRACTORS SHALL CONTACT THE BUILDING MANAGEMENT TO DETERMINE THE RULES
<br /> 22.VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW EXCEPT AS PROVIDED IN NFPA STANDARO 30 AND THE(2015IBC W/TH WAC 51-50&2015 OF THE BUILDING OWNER FOR CONSTRUCTION TO DETERMINE WHEN&HOW DELIVERIES CAN
<br /> MANUFACTURERS. IEBC WITH WAC 51-50). PERMIT MAY BE REQUIRED. BE MADE(SEE BELOW),WHAT PHASES OF CONSTRUCTION CAN BE DONE ON REGULAR OR
<br /> 23.CONSTRUCTION WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW 9.ALL DRAPES,HANGINGS,CURTAINS,AND ALL OTHER DECORATIVE MATERIALS THAT OVERTIME,&IN GENERAL ANY SPECIAL BUILDING REQUIREMENTS WHICH WILL AFFECT THEIR
<br /> CONSTRUCTION UON. WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM WORK(IF OVERTIME WORK IS REQUIRED BY ANY TRADE,APPROVAL MUST BE OBTAINED PRIOR
<br /> 24.COORDINATION:THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION NONFLAMMABLE MATERIAL,OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT TO THE EXECUTION OF ANY WORK INCLUDING COST).THE GENERAL INTENT IS THAT ALL
<br /> AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE CONDITION BY MEANS OF A FLAME RETARDANT SOLUTIONS OR PROCESS APPROVED BY CONSTRUCTION WORK SHALL BE DONE ON REGULAR TIME EXCEPT NOISE GENERATING
<br /> DRAWINGS. THE FIRE MARSHAL.PROVIDE A CERTIFICATION TO THIS EFFECT.EXIT DOORS,EXIT LIGHTS, CONSTRUCTION.
<br /> 25.ALL CONSTRUCTION AND DESIGN TO BE IN COMPLIANCE WITH UNISPACE DESIGN AND AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY 14.THE GENERAL CONTRACTOR,HIS/HER SUBCONTRACTOR&ANY OTHER CONTRACTOR
<br /> CONSTRUCTION GUIDELINES. DECORATIVE MATERIAL.MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COST CAUSED BY DEFECTIVE OR ILL-
<br /> 26.REFER TO CLIENT'S BID FORMS AND EXECUTED CONTRACT FOR CONSTRUCTION FOR FULL SHALL CONFORM TO THE(201518C W1TH WAC 51-50&2015►EBC WITH WAC 51-50). TIMED WORK AS A RESULT OF,BUT NOT LIMITED TO INFERIOR WORKMANSHIP OR MATERIALS,
<br /> LIST OF CONTRACT DOCUMENTS. 10.ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING IMPROPER SCHEDULING OR DELINQUENT ORDERING SHALL BE BORNE BY THE PARTY
<br /> 27.THE DRAWINGS,CLIENT'S STANDARD SPECIFlCATlONS,AND ALL OTHER GONTRAGT THE SPECIFIC RATING. RESPONSIBLE THEREFORE.
<br /> DOCUMENTS ARE COMPLEMENTARY.WHERE CONFLICTS OR DIFFERENCES OCCUR 15.THE USE OF THE WORDS"PROVIDE"OR"PROVIDED" IN CONNECTION WITH ANY ITEM SPECIFIED
<br /> CONTRACTOR SHALL BRING THEM TO THE ATTENTION OF UNISPACE DURING BID.WHERE IS INTENDED TO MEAN,UNLESS OTHERWISE NOTED,THAT WHICH SHALL BE FURNISHED&
<br /> DIFFERENCES ARE NOT BROUGHT TO UNISPACE'S ATTENTION DURING BID,THE COSTLIER OR INSTALLED,&CONNECTED WHERE SO REQUIRED.
<br /> MORE RESTRICTIVE SHALL BE DEEMED THE CONTRACT REQUIREMENT. 16.WHERE THE TERMS"APPROVED EQUAL","OTHER APPROVED","EQUAL TO", "ACCEPTABLE"OR
<br /> 28.THE CONTRACTOR SHALL NOTIFY UNISPACE OF ANY DISCREPANCIES BETWEEN THE THE OTHER GENERAL QUALIFYING TERMS ARE USED IN THESE NOTES, IT SHALL BE
<br /> CONSTRUCTION DOCUMENTS AND ANY FIELD CONDITIONS,WHICH MAY GAUSE DEVIATION UNDERSTOOD THAT REFERENCE IS MADE TO THE RULING&JUDGMENT OF UNISPACE.
<br /> FROM THE CONSTRUCTION DOCUMENTS,PRIOR TO SUBMITTING BIDS.
<br /> Stamp:
<br /> � wJ ��..� � �q}� �
<br /> i � .,�.u.�.<,.:>.a8 �
<br /> ��yt��.��,";�ih A�
<br /> �T'�a�����dh`S;�ii^a a t Lid
<br /> � ,/. ,.--
<br /> GENERAL SYMBOLS STANDARD ABBREVIATIONS � �
<br /> ���PROJECT NORTH & -AND GA-GAUGE PERF- PERFORATED
<br /> ' @ -AT GALV-GALVANIZED PERP-PERPENDICULAR
<br /> -- TRUE NORTH � -CENTER LINE GB-GRAB BAR PL-PLATE
<br /> # -POUND GC-GENERAL CONTRACTOR PLBG-PLUMBING
<br /> ± -TOLERANCE DIMENSION GEN -GENERATOR PR-PAIR
<br /> �=' AREA NOT IN CONTRACT GFRC-GLASS FIBER REINFORCED CONCRETE PREFAB-PREFABRICATED
<br /> A/E -ARCHiTECT/ENGINEER GFRG-GLASS FIBER REINFORCED GYPSUM PT- PRESSURE TREATED
<br /> ACT-ACOUSTIC CEILING TILE GL-GLASS PTD-PAINTED
<br /> RM.NAME.._--ROOM NAME ADA-THE AMERICANS WITH DISABILITIES ACT GWB-GYPSUM WALL BOARD PVC-POLYVINYL CHLORIDE
<br /> 101 �.. ROOM/AREA NUMBER ADJ-ADJACENT
<br /> 150 SF„
<br /> AREA AFF-ABOVE FINISHED FLOOR HB-HOSE BIBB QTY-QUANTITY
<br /> AH -AIR HANDLER HC-HOLLOW CORE
<br /> ...� ALT-ALTERNATE HT-HEIGHT R-RADIUS OR(STAIR) RISERS
<br /> ; � � S�M---REF. TYPE (IF APPLICABLE) APPROX-APPROXIMATELY HM-HOLLOW METAL RAD-RADIATOR
<br /> � � 6_22 DETAIL REFERENCE NUMBER ARCH-ARCHITECT HO-HOLD OPEN RCP- REFLECTED CEILING PLAN
<br /> � j DETAII.REFERENCE SHEET HORIZ- HORIZONTAL RD-ROOF DRAIN
<br /> � AREA OF DETAIL BD-BOARD HP- HIGH POINT REF-REFERENCE REv DESCRIPTION DATE BY CHK
<br /> BLDG-BUILDING HVAC-HEAT, VENTILATION &AIR CONDITIONING REFR- REFRIGERATOR Key P;an
<br /> BM-BEAM REINF- REINFORCED OR REINFORCING �^[,�����
<br /> � S�M---REF. TYPE (IF APPLICABLE) ID- INSIDE DIAMETER REQD- REQUIRED ' '-�`�=� � ,�."��
<br /> EXTERIOR ELEVATION NUMBER CAB-CABINET IN - INCH OR INCHES RH -RIGHT HAND
<br /> ^����
<br /> A1-101 CG-CORNER GUARD INSUL- INSULATION RHR-RIGHT HAND REVERSE .-. ; - '
<br /> SHEET NUMBER
<br /> CLG-CEILING INT- INTERIOR RM-ROOM ��( � `�� �
<br /> � CLR-CLEAR RO-ROUGH OPENING � : : : � �✓��-�"�`
<br /> �ELEVATION NUMBER TYP. CMU -CONCRETE MASONRY UNIT JAN -JANITOR RWL-RAIN WATER LEADER ����,�='�� � , ��
<br /> 1 A2-222 1 ��-� . �� .
<br /> COL-COLUMN r-- � �
<br /> SHEET NUMBER CONC-CONCRETE KD-KNOCKED DOWN SAFB-SOUND ATTENUATION FIBER BLANKET �,,�: : : : : : '� � �
<br /> 1 C O N T-C O N T I N U O U S K O-K N O C K O U T S F-S Q U A R E F O O T O R F E E T `� � � � �
<br /> �__�
<br /> I __�_._�� . . . . . . ,
<br /> CYL-CYLINDER SIM-SIMILAR
<br /> S�M - REF. TYPE (IF APPLICABLE) L-LENGTH OR LEFT SK-SINK : e :��� -
<br /> t_ _ 1
<br /> 6-2 - SECTION NUMBER DEMO- DEMOLITION LAB-LABORATORY SPEC-SPECIFICATIONS � ����-. ;-
<br /> SHEET NUMBER D E P T-D E P A R T M E N T L A M-L A M I N A T E S Q-S Q U A R E �r�`� � � ''
<br /> DIA- DIAMETER LAV-LAVATORY ST-STREET lr4 �� � �� `
<br /> ��uv.t Ti�'�`
<br /> DIM-DIMENSION LB-POUND STC-SOUND TRANSMISSION CLASS Client/Project Name/Address:
<br /> S�M �REF. TYPE (IF APPLICABLE) DISP- DISPENSER LF-LINEAR FOOT OR FEET STD-STANDARD �
<br /> � 6-22 �DETAIL SECTION NUMBER DIV-DIVISION LH- LEFT HAND STG-STORAGE _
<br /> -- SHEET NUMBER DN -DOWN LHR-LEFT HAND REVERSE STL-STEEL F LU KE - D PO D �
<br /> DWG-DRAWING L►N - LINEAR STN-STONE m
<br /> LP-LOW POINT STR-STRUCTURAL 6920 SEAWAY BLVD J�
<br /> --- 22 GRID LINE NUMBER EA-EACH LTG-LIGHTING EVERETT, WA 98203 �
<br /> �
<br /> EIFS-EXTERIOR INSULATION FINISH SYSTEM T-TREADS (STAIRS) �
<br /> LEVEL 1 � LEVEL NAME EJ-EXPANSION JOINT MACH-MACHINE T&G-TONGUE AND GROOVE �
<br /> 12'-6" EL- ELEVATION MAX- MAXIMUM TBD-TO BE DETERMINED Drawing Title: a
<br /> ELEC-ELECTRICAL MDF-MEDIUM DENSITY FIBERBOARD TEL-TELEPHONE
<br /> LEVEL ELEVATION ELEV- ELEVATOR MECH -MECHANICAL TEMP-TEMPORARY ;'
<br /> Q REVISION NUMBER EMER-EMERGENCY MFR-MANUFACTURER TOFF-TOP OF FINISHED FLOOR G E N E RAL N OTES� Q
<br /> ENGR-ENGINEER MIN-MINIMUM T.O. -TOP OF �
<br /> ALIGN EP- ELECTRICAL PANEL MIR-MIRROR TPO-THERMOPLASTIC-POLYOLEFIN ROOFING SYM BO LS & �
<br /> ("'"" � ALIGN TO iNDICATED EPDM-ETHYLENE PROPYLENE DIENE MONOMER MISC-MISCELLANEOUS TV-TELEVISION OR MONITOR N
<br /> r SURFACES EQ-EQUAL MO-MASONRY OPENING TYP-TYPICAL AB B REVIATIO NS j�
<br /> EQUIP-EQUIPMENT MTD-MOUNTED �
<br /> ALIGN TO INDICATED EX/EXIST-EXISTING MTL-METAL UL-UNDERWRITERS LABORATORY w
<br /> OPPOSITE SURFACES EXH-EXHAUST UON-UNLESS OTHERWISE NOTED status: �
<br /> N/A-NOTAPP�ICABLE UPS-UNINTERRUPTIBLEPOWERSUPPLY CONSTRUCTION �
<br /> O SHEET-KEYNOTES FA-FIRE ALARM NIC-NOT IN CONTRACT UV- ULTRAV►OLET �
<br /> FACP- FIRE ALARM CONTROL PANEL NOM-NOMINAL SET L
<br /> FD-FLOOR DRAIN NTS-NOT TO SCALE VAC-VACUUM m
<br /> � CENTER LINE FDC-FIRE DEPARTMENT CONNECTION VCT-VINYL COMPOSITION TILE Drawn By: KS Checked By: PM `,
<br /> FE-FIRE EXTINGUISHER OA-OVERALL VERT-VERTICAL sca�e: 12"=1'-0" Date: 05/11/18 �
<br /> FEC- FIRE EXTINGUISHER CABINET O.C. -ON CENTER VEST-VESTIBULE Project Number. �
<br /> FHC-FIRE HOSE CABINET OD-OUTSIDE DIAMETER VIF-CONTRACTOR TO VERIFY W FIELD SEA-0057A �
<br /> OFCI-OWNER FURNISHED/CONTRACTOR INSTALLED N
<br /> FIN-FINISH OF01-OWNER FURNISHED/OWNER INSTALLED W-WEST Drawinq Number: Revision: a
<br /> FLR-FLOOR OPP-OPPOSITE W/-WITH N
<br /> FT-FOOT OR FEET W/0-WITHOUT `°
<br /> FTG-FOOTING WC-WATER CLOSET � o
<br /> FTR-FIN TUBE RADIATION WP-WORKING POINT Z
<br /> FURN-FURNITURE -� o a