Laserfiche WebLink
1111 <br /> V` A <br /> 2 �•z 3 z V'�� <br /> .....w...,_N..va,.r;$. .,.,- .r..,.., .WIM.k...-0..Na.t .,v a.....,.A...: ..,..< .s.., ...,.txo_x....r....s.. .,t..>.. .. ag .VaIa te <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required, select the box next to(b)and (c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *If item(a)-(ii,iii,or v)is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3) Electrical plan review. <br /> 0 (a) Electrical plan review is not required for: <br /> ❑ (i) Low voltage systems; <br /> 4-1:1 (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> ❑ does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or • <br /> (C)A required fire pump system. <br /> ❑ (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> • (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total <br /> ❑ rating of 9600 watts or less. <br /> (vii) For installations in(a)(ii),(iii),and(v)of this subsection to be considered,the following must be available <br /> ❑ to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical,dental, and chiropractic clinic"of which is a clinic or <br /> ❑ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> ® (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care <br /> occupancies defined in this chapter. <br /> ® (c) If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Tabre1OO- aksl 9U1F 2 <br /> Reaffx4ii Per ohat Care i±,.eil.Wes• Educatronat acid netati cm4I 0 c€0* P a es`crF A sea t ty a Oher FOCTitie*. <br /> Health or Pers.O al cere csiity Plan Ftarriieuu' • <br /> Rff Regtirt ErtYtfia y413 �4k€:st a fitb 4 t as F.1ork7teA+'lo!o.. <br /> de <br /> 1pspital s ci€tcer.'F€tY'r kt*A40.* Re tcrr t! <br /> okirsiogliOme aYtit rfong=terit4 Ye's E"tttCaa st. 5'e' <br /> care a$ t Sl7slC qi 3�kiFa€ ' <br /> teen: a home Yes <br /> r`as d Jr r€rig J tstr£fkj Yk0 <br /> t rdvate alcoholism hnspltet 'Yes t 3 it:5 tU a#ttes;9tiF1 !YD3i1 9t10 2, <br /> PriMg".,0)gtaa `.k rl0§ Yds ' A d .attt q 4,k to pier tei Crcal ii3stsftO s. <br /> € erratny home Yes n . <br /> • i r qU a t314a3'`i-41.0?a.gra fec(lity types not <br /> iiirmb046.6t'sirgehi.f#ility Ye$ rera tr s by h ¢a�artmen#, <br /> Rena isemadiatjla.ciieic Yes <br /> Bees€seatta€tsgattetit€Deity Yep <br /> .Enhanced.service fadihty. Yes. <br /> A Itrk:si antl#retieldil iat@j1 Yes PERMIT# Page 2-Plan Review <br /> e�nEer <br />